MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system

被引:12
|
作者
Harman, M
Ipeksoy, U
Dogan, A
Arslan, H
Etlik, O
机构
[1] Univ Yuzuncu Yil, Fac Med, Dept Radiol, Van, Turkey
[2] Univ Yuzuncu Yil, Fac Med, Dept Orthoped Surg, Van, Turkey
关键词
MR arthrography; chondromalacia patellae; low-field MRI;
D O I
10.1016/S0899-7071(02)00521-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to compare the diagnostic efficacy conventional MRI and MR arthrography (MRA) in the diagnosis of chondromalacia patella (CP) on a low-field open magnet system (LFOMS), correlated with arthroscopy. Subjects and methods: Forty-two patients (50 knees) with pain in the anterior part of the knee were prospectively examined with LFOMS, including T1-weighted, proton density-weighted and T2-weighted sequences. All were also examined T1-weighted MRI after intraarticular injection of dilue gadopentetate dimeglumine. Two observers, who reached a consensus interpretation, evaluated each imaging technique independently. Thirty-six of the 50 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity and accuracy of each imaging technique in the diagnosis of each stage of CP were determined and compared by using the McNemar two-tailed analysis. Results: Arthroscopy showed that 16 facets were normal. Four (30%) of 13 grade 1 lesions were detected with T1. Four lesions (30%) with T2 and three lesions (23%) with proton-weighted images were detected. Seven (53%) of 13 grade 1 lesions were detected with MRA. Grade 2 abnormalities were diagnosed in two (33%) of six facets with proton density-weighted pulse sequences, two (33%) of six facets with T1-weighted pulse sequences, in three (50%) of six facets with T2-weighted pulse sequences, in five (83%) of six facets with MRA sequences. Grade 3 abnormalities were diagnosed in three (71%) of seven facets with proton density- and T1-weighted images, five (71%) of seven facets with T2-weighted pulse sequences, six (85%) of seven facets with MRA sequences. Grade 4 CP was detected with equal sensitivity with T1-, proton density- and T2-weighted pulse sequences, all showing seven (87%) of the eight lesions. MRA again showed these findings in all eight patients. All imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesion, so that no significant difference among the techniques could be shown. Conclusion: All imaging technique studied had high specificity and accuracy in the detection and grading of CP; however, MRA was more sensitive than T1-weighted and proton density-weighted MR imaging on a LFOMS. Although the arthrographic techniques were not significantly better than T2-weighted imaging, the number of false-positive diagnosis was greatest with T2-weighted MRI. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [21] MR imaging-guided biliary drainage in an open low-field system: First clinical experiences
    Wacker, FK
    Faiss, S
    Reither, K
    Zimmer, T
    Wendt, M
    Wolf, KJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (09): : 744 - 747
  • [22] A low-field, low-cost Halbach magnet array for open-access NMR
    Hills, BP
    Wright, KM
    Gillies, DG
    JOURNAL OF MAGNETIC RESONANCE, 2005, 175 (02) : 336 - 339
  • [23] Low-Field Rampable Magnet for a High-Resolution MRI System
    Rigla, Juan P.
    Bodker, Franz
    Anari, Amir
    Pallas, Eduardo
    Grau, Daniel
    Puchalt, Guillermo
    Gonzalez, Jose M.
    Corberan, Miguel
    Diaz, Elena
    Algarin, Jose M.
    Rios, Alfonso
    Benlloch, Jose M.
    Alonso, Joseba
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (02)
  • [24] Static and dynamic evaluation of pelvic floor disorders with an open low-field tilting magnet
    Fiaschetti, V.
    Pastorelli, D.
    Squillaci, E.
    Funel, V.
    Rascioni, M.
    Meschini, A.
    Salimbeni, C.
    Sileri, P.
    Franceschilli, L.
    Simonetti, G.
    CLINICAL RADIOLOGY, 2013, 68 (06) : E293 - E300
  • [25] Quantifying Liver Fat Using a Low-Field Unilateral MR System
    von Morze, Cornelius
    Blazey, Tyler
    Conradi, Mark S.
    APPLIED MAGNETIC RESONANCE, 2023, 54 (11-12) : 1365 - 1376
  • [26] Quantifying Liver Fat Using a Low-Field Unilateral MR System
    Cornelius von Morze
    Tyler Blazey
    Mark S. Conradi
    Applied Magnetic Resonance, 2023, 54 : 1365 - 1376
  • [27] Intracranial MR Venography Using Low-Field Magnet: Normal Anatomy and Variations in Nepalese Population
    Sharma, U. K.
    Sharma, K.
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2012, 52 (02) : 61 - 65
  • [28] MR monitoring of laser-induced lesions of the liver in vivo in a low-field open magnet: Temperature mapping and lesion size prediction
    Germain, D
    Chevallier, P
    Laurent, A
    Savart, M
    Wassef, M
    Saint-Jalmes, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (01) : 42 - 49
  • [29] Diffusion weighted mr imaging on a low-field open magnet - Comparison with findings at 1.5T in 18 patients with cerebral ischemia
    Mehdizade, A
    Somon, T
    Wetzel, S
    Kelekis, A
    Martin, JB
    Scheidegger, JR
    Sztajiel, R
    Lovblad, KO
    Ruefenacht, DA
    Delavelle, J
    JOURNAL OF NEURORADIOLOGY, 2003, 30 (01) : 25 - 30
  • [30] MR-guided biopsies with a newly designed cordless coil in an open low-field system: Initial findings
    Zangos, Stephan
    Vetter, Theodor
    Huebner, Frank
    Tuwari, Montu
    Mayer, Florian
    Eichler, Katrin
    Hansmann, M. -L.
    Wetter, A.
    Herzog, C.
    Vogl, Thomas J.
    EUROPEAN RADIOLOGY, 2006, 16 (09) : 2044 - 2050