A sector-integration method for dose/MU calculation in a uniform scanning proton beam

被引:7
|
作者
Zhao, Qingya [1 ,2 ]
Wu, Huanmei [3 ]
Wolanski, Mark [1 ]
Pack, Daniel [1 ]
Johnstone, Peter A. S. [1 ,4 ]
Das, Indra J. [1 ,4 ]
机构
[1] Midwest Proton Radiotherapy Inst, Bloomington, IN USA
[2] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[3] IUPUI, Purdue Sch Engn & Technol, Indianapolis, IN USA
[4] Indiana Univ, Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 03期
关键词
MONITOR UNIT CALCULATIONS; BRAGG PEAK FIELDS; DOSIMETRY; THERAPY; DETECTORS; SCATTER; RANGE;
D O I
10.1088/0031-9155/55/3/N02
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate, simple and time-saving sector integration method for calculating the proton output (dose/monitor unit, MU) is presented based on the following treatment field parameters: aperture shape, aperture size, measuring position, beam range and beam modulation. The model is validated with dose/MU values for 431 fields previously measured at our center. The measurements were obtained in a uniform scanning proton beam with a parallel plate ionization chamber in a water phantom. For beam penetration depths of clinical interest (6-27 cm water), dose/MU values were measured as a function of spread-out Bragg peak (SOBP) extent and aperture diameter. First, 90 randomly selected fields were used to derive the model parameters, which were used to compute the dose/MU values for the remaining 341 fields. The min, max, average and the standard deviation of the difference between the calculated and the measured dose/MU values of the 341 fields were used to evaluate the accuracy and stability, for different energy ranges, aperture sizes, measurement positions and SOBP values. The experimental results of the five different functional sets showed that the calculation model is accurate with calculation errors ranging from -2.4% to 3.3%, and 99% of the errors are less than +/- 2%. The accuracy increases with higher energy, larger SOBP and bigger aperture size. The average error in the dose/MU calculation for small fields ( field size <25 cm(2)) is 0.31 +/- 0.96 (%).
引用
收藏
页码:N87 / N95
页数:9
相关论文
共 50 条
  • [1] MU Calculation for Uniform Scanning Proton Beam
    Zhao, Q.
    Wu, H.
    Wolanski, M.
    Hecksel, D.
    Pack, D.
    Das, I.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2795 - +
  • [2] Irregular field calculation on the central beam axis of photon beams using sector-integration
    Sanz, DE
    Romaguera, AL
    Acosta, NB
    [J]. MEDICAL PHYSICS, 2001, 28 (07) : 1344 - 1351
  • [3] Photon output factor calculation from the inverse of the sector-integration equation
    Sanz, DE
    Romaguera, AL
    Acosta, NB
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1447 - 1453
  • [4] The Effect of Scanning Pattern and Dose Rate on Output Factor for Uniform Scanning Proton Beam
    Zhao, Q.
    Wu, H.
    Pack, D.
    Cheng, C.
    Das, I.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [5] Clinical implementation of a sector-integration method for calculating electron output factors
    Vossler, M.
    Helmuth, K.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2425 - 2425
  • [6] Dose monitoring and output correction for the effects of scanning field changes with uniform scanning proton beam
    Zhao, Qingya
    Wu, Huanmei
    Cheng, Chee-Wai
    Das, Indra J.
    [J]. MEDICAL PHYSICS, 2011, 38 (08) : 4655 - 4661
  • [7] Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients
    Grassberger, C.
    Lomax, Anthony
    Paganetti, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 633 - 645
  • [8] A sector-integration method for calculating the output factors of irregularly shaped electron fields
    Jursinic, PA
    Mueller, R
    [J]. MEDICAL PHYSICS, 1997, 24 (11) : 1765 - 1769
  • [9] BNCT dose calculation in irregular fields using the sector integration method
    Blaumann, HR
    Sanz, DE
    Longhino, JM
    Larrieu, OAC
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 835 - 840
  • [10] Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking
    Farr, J. B.
    Mascia, A. E.
    Hsi, W. -C.
    Allgower, C. E.
    Jesseph, F.
    Schreuder, A. N.
    Wolanski, M.
    Nichiporov, D. F.
    Anferov, V.
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4945 - 4954