Moisture conditions of outdoor air-ventilated crawl spaces in apartment buildings in a cold climate

被引:13
|
作者
Kurnitski, J [1 ]
Matilainen, M [1 ]
机构
[1] Aalto Univ, HVAC Lab, FIN-02015 Helsinki, Finland
关键词
crawl space; dynamic simulation; moisture evaporation; optimum air change; ground covers;
D O I
10.1016/S0378-7788(00)00061-X
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of air change and ground covers on crawl space moisture balance in a cold climate are discussed in this paper. The objectives were to assess the suitability of outdoor air-ventilation in the crawl spaces of apartment buildings, to determine the optimum air change rate with and without ground covers, and the effect of the ground covers' thermal insulation on moisture behaviour. Measured data from the test building was used to develop the crawl space model in a modular simulation environment, where the parametric simulations were carried out. The air change rate was varied between 0-10 ach to study moisture behaviour with covered and uncovered ground surface. Moisture evaporation was included in the moisture balance, but moisture storage in the constructions and in the ground was not. The results show that evaporation and thermal behaviour are the key elements determining the resulting relative humidity in crawl spaces. If moisture evaporation is entirely prevented, the crawl space may be left unventilated. In other cases, ventilation is always required to remove the moisture. The higher air change rates increased moisture evaporation from uncovered ground, but still brought about lower relative humidity. The rise from 0.5 to 3 ach increased evaporation from 2.4 to 4.9 g/m(2) h and decreased the highest monthly average of relative humidity from 81 to 74%. For the uncovered ground the lowest relative humidity was achieved at 2-3 ach air change in winter, but in the summer, the higher the air change the lower the relative humidity. Ground covers made it possible to decrease relative humidity and to increase temperature significantly due to reduced moisture evaporation. Ground cover with thermal insulation was in principle more effective than without insulation as it provided a slightly higher temperature rise in summer. The studied 5 cm expanded polystyrene layer reduced moisture evaporation to 0.3-0.4 g/m(2) h, increased crawl space temperature by 2-3 degrees C and decreased relative humidity below the 60% level when air change was 0.5-1 ach. In general, outdoor air-ventilation demonstrated very high performance in the crawl space of the studied apartment building when a ground cover was applied. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:15 / 29
页数:15
相关论文
共 50 条
  • [21] Adaptation of Users to Future Climate Conditions in Naturally Ventilated Historic Buildings: Effects on Indoor Comfort
    Fiorito, Francesco
    Vurro, Giandomenico
    Carlucci, Francesco
    Campagna, Ludovica Maria
    De Fino, Mariella
    Carlucci, Salvatore
    Fatiguso, Fabio
    [J]. ENERGIES, 2022, 15 (14)
  • [22] Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature
    Byun, Jae-Ki
    Choi, Young-Don
    Shin, Jong-Keun
    Park, Myung-Ho
    Kwak, Dong-Kurl
    [J]. ENERGIES, 2012, 5 (05): : 1686 - 1704
  • [23] Green Technologies for Energy-Efficient Buildings in Cold Climate Conditions of Russia
    Sharovarova, E. P.
    Alekhin, V. N.
    Maltseva, I. N.
    [J]. INTERNATIONAL CONFERENCE ON CONSTRUCTION, ARCHITECTURE AND TECHNOSPHERE SAFETY (ICCATS 2017), 2017, 262
  • [24] Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China
    Yang, Wei
    Zhang, Guoqiang
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2008, 52 (05) : 385 - 398
  • [25] Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China
    Wei Yang
    Guoqiang Zhang
    [J]. International Journal of Biometeorology, 2008, 52 : 385 - 398
  • [26] Towards moisture safe ventilated cold attics - Monitored conditions in a full-scale test building
    Hansen, Thor
    Moller, Eva
    Peuhkuri, Ruut
    [J]. 12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [27] Proposal for a Simplified CFD Procedure for Obtaining Patterns of the Age of Air in Outdoor Spaces for the Natural Ventilation of Buildings
    Angel Padilla-Marcos, Miguel
    Meiss, Alberto
    Feijo-Munoz, Jesus
    [J]. ENERGIES, 2017, 10 (09):
  • [28] Reducing the defrosting needs of air-handling units by using heat from wastewater in apartment buildings in cold climates
    Ploskic, Adnan
    Wang, Qian
    [J]. APPLIED THERMAL ENGINEERING, 2019, 157
  • [29] Assessment of thermal environmental conditions and quantification of thermal adaptation in naturally ventilated buildings in composite climate of India
    Dhaka, Shivraj
    Mathur, Jyotirmay
    Brager, Gail
    Honnekeri, Anoop
    [J]. BUILDING AND ENVIRONMENT, 2015, 86 : 17 - 28
  • [30] OUTDOOR CLIMATE CHANGE ANALYSIS IN UNIVERSITY CAMPUS: CASE STUDY WITH HEAT-AIR-MOISTURE SIMULATION
    Juras, Peter
    Jurasova, Daniela
    [J]. CIVIL AND ENVIRONMENTAL ENGINEERING, 2020, 16 (02) : 370 - 378