Towards moisture safe ventilated cold attics - Monitored conditions in a full-scale test building

被引:0
|
作者
Hansen, Thor [1 ]
Moller, Eva [2 ]
Peuhkuri, Ruut [3 ]
机构
[1] Danish Technol Inst, DK-2630 Taastrup, Denmark
[2] Tech Univ Denmark, Dept Civil Engn, DK-2800 Lyngby, Denmark
[3] Aalborg Univ, Dept Built Environm, DK-2450 Copenhagen SV, Denmark
关键词
D O I
10.1051/e3sconf/202017223003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Existing building stock in Europe accounts for approx. 40% of the total energy consumption. Upgrading the thermal insulation of the existing buildings is an important measure to reduce heat losses through the building envelope. In some cases, increasing the thermal resistance of the construction may compromise the hygrothermal performance of the retrofitted construction. In particular, if vapour barrier is necessary for the good performance and it is practically difficult, if not even impossible, to install a well-sealed air- and vapour tight layer. To investigate the robustness of the hygrothermal performance of ventilated cold attics - with or without a vapour barrier - a monitoring campaign in a full-scale test building was set up. Also role of number of other parameters like moisture buffering capacity of the insulation material and thermal resistance was investigated. This paper presents part of this measuring campaign, which includes conditions both in the attic space and inside the insulation layer. The monitored data covers a period with two winters. The results show that it in temperate climate is practically indifferent for the hygrothermal performance of the monitored, well-ventilated attics with air-tight ceilings whether there is a vapour barrier or not and if the insulation material has moisture buffering capacity or not.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hygrothermal performance of cold ventilated attics above different horizontal ceiling constructions: Full-scale test building
    Hansen, Thor
    Moller, Eva B.
    Tvedebrink, Torben
    [J]. JOURNAL OF BUILDING PHYSICS, 2020, 44 (01) : 67 - 91
  • [2] Full-scale cold bending demonstration test
    Gergess, Antoine N.
    Sen, Rajan
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (10) : 1295 - 1304
  • [3] FULL-SCALE TEST OF BUILDING A BRIDGE BY THE BALANCED LIFT METHOD
    Kollegger, Johann
    Gmainer, Susanne
    Wimmer, David
    [J]. FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 471 - 474
  • [4] Full-scale method for testing moisture conditions in painted wood paneling
    Hjort, S
    [J]. JOURNAL OF COATINGS TECHNOLOGY, 1996, 68 (856): : 31 - 39
  • [5] A full-scale experimental study concerning the moisture condensation on building glazing surface
    Nguyen, Chi-Kien
    Teodosiu, Catalin
    Kuznik, Frederic
    David, Damien
    Teodosiu, Raluca
    Rusaouen, Gilles
    [J]. BUILDING AND ENVIRONMENT, 2019, 156 : 215 - 224
  • [6] Heat Transfer Analysis of Full-Scale Safe Rooms Exposed to Bushfire Conditions
    Hendawitharana, Sahani
    Ariyanayagam, Anthony
    Mahendran, Mahen
    [J]. FIRE TECHNOLOGY, 2024, 60 (01) : 239 - 271
  • [7] Heat Transfer Analysis of Full-Scale Safe Rooms Exposed to Bushfire Conditions
    Sahani Hendawitharana
    Anthony Ariyanayagam
    Mahen Mahendran
    [J]. Fire Technology, 2024, 60 : 239 - 271
  • [8] Full-scale test behavior of cold-formed steel roof trusses
    Wood, JV
    Dawe, JL
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2006, 132 (04) : 616 - 623
  • [9] Full-scale test of an old heritage multi-storey building undergoing energy retrofitting with focus on internal insulation and moisture
    Harrestrup, M.
    Svendsen, S.
    [J]. BUILDING AND ENVIRONMENT, 2015, 85 : 123 - 133
  • [10] Seismic Performance of Cold-Formed Steel Wall Systems in a Full-Scale Building
    Wang, X.
    Pantoli, E.
    Hutchinson, T. C.
    Restrepo, J. I.
    Wood, R. L.
    Hoehler, M. S.
    Grzesik, P.
    Sesma, F. H.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (10)