Full-scale test of an old heritage multi-storey building undergoing energy retrofitting with focus on internal insulation and moisture

被引:62
|
作者
Harrestrup, M. [1 ]
Svendsen, S. [1 ]
机构
[1] Tech Univ Denmark DTU, Dept Civil Engn, Sect Bldg Energy, DK-2800 Lyngby, Denmark
关键词
Energy renovation; Heritage building; Internal insulation; Full scale measurements; Numerical simulations; Moisture safe solutions; MOLD GROWTH; TEMPERATURE; HUMIDITY;
D O I
10.1016/j.buildenv.2014.12.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The hypothesis investigated in this article is: it is possible to carry out moisture safe energy renovations in the old existing multi-storey buildings with heritage value and still save 50% of the building's energy consumption by use of existing technologies. A holistic energy renovation on an old multi-storey building with heritage value was carried out. Focus was given to energy-saving measures that would preserve the original architectural expression of the building, such as internal insulation. Comprehensive measurements were performed on the energy consumption before and after the renovation to document the obtained savings. Numerical simulations were validated with the measurements in order to explain the savings and to carry out parameter variations on the energy saving measures. Since internal insulation was applied the durability and robustness were investigated and measurements of the temperature and relative humidity were performed in the wooden beams-ends embedded in the masonry brick wall. A solution where the insulation was stopped 200 mm above the floor was investigated. This increased the heat flows through the wall compared to a fully insulated wall, and calculations showed that the difference in the space heating consumption was 3 kWh/m(2)/yr. The measurements showed the proposed solution should have no risk of moisture problems. The measured energy consumption was reduced with 47% whereas the theoretical reduction could be reduced with 39-61% depending on the room set-point temperature (20-24 degrees C). (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:123 / 133
页数:11
相关论文
共 12 条
  • [1] Fire behaviour of continuous reinforced concrete slabs in a full-scale multi-storey steel-framed building
    Li, B.
    Dong, Y. -L.
    Zhang, D. -S.
    [J]. FIRE SAFETY JOURNAL, 2015, 71 : 226 - 237
  • [2] Fire Scenarios for Multi-storey Facades with Emphasis on Full-Scale Testing of Wooden Facades
    Ostman, Birgit
    Tsantaridis, Lazaros
    [J]. FIRE TECHNOLOGY, 2015, 51 (06) : 1495 - 1510
  • [3] Fire tests on two-way concrete, slabs in a full-scale multi-storey steel-framed building
    Yang, Z. N.
    Dong, Y. L.
    Xu, W. J.
    [J]. FIRE SAFETY JOURNAL, 2013, 58 : 38 - 48
  • [4] Energy efficient solutions for retrofitting a residential multi-storey building with vacuum insulation panels and low-E windows in two European climates
    Urbikain, M. Karmele
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 269
  • [5] Internal insulation applied in heritage multi-storey buildings with wooden beams embedded in solid masonry brick facades
    Harrestrup, M.
    Svendsen, S.
    [J]. BUILDING AND ENVIRONMENT, 2016, 99 : 59 - 72
  • [6] Fire Scenarios for Multi-storey Façades with Emphasis on Full-Scale Testing of Wooden Façades
    Birgit Östman
    Lazaros Tsantaridis
    [J]. Fire Technology, 2015, 51 : 1495 - 1510
  • [7] Effects of different insulation materials on primary energy and CO2 emission of a multi-storey residential building
    Tettey, Uniben Yao Ayikoe
    Dodoo, Ambrose
    Gustavsson, Leif
    [J]. ENERGY AND BUILDINGS, 2014, 82 : 369 - 377
  • [8] Towards moisture safe ventilated cold attics - Monitored conditions in a full-scale test building
    Hansen, Thor
    Moller, Eva
    Peuhkuri, Ruut
    [J]. 12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [9] SOFIE project-3D shaking table test on a seven-storey full-scale cross-laminated timber building
    Ceccotti, Ario
    Sandhaas, Carmen
    Okabe, Minoru
    Yasumura, Motoi
    Minowa, Chikahiro
    Kawai, Naohito
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (13): : 2003 - 2021
  • [10] Energy retrofitting of a typical old Danish multi-family building to a "nearly-zero" energy building based on experiences from a test apartment
    Morelli, Martin
    Ronby, Leif
    Mikkelsen, Svend Erik
    Minzari, Maja G.
    Kildemoes, Troels
    Tommerup, Henrik M.
    [J]. ENERGY AND BUILDINGS, 2012, 54 : 395 - 406