Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

被引:2
|
作者
Byun, Jae-Ki [1 ]
Choi, Young-Don [1 ]
Shin, Jong-Keun [2 ]
Park, Myung-Ho [3 ]
Kwak, Dong-Kurl [4 ]
机构
[1] Korea Univ, Dept Mech Engn, State Key Lab Renewable Energy Syst & Turbulent F, Seoul 136713, South Korea
[2] Hanzhong Univ, Dept Automot Engn, Gangwondo 240713, South Korea
[3] Kangwon Natl Univ, Dept Mech Engn, Gangwondo 245711, South Korea
[4] Kangwon Natl Univ, Dept Elect & Control Engn, Gangwondo 245711, South Korea
来源
ENERGIES | 2012年 / 5卷 / 05期
关键词
optimal control; distribution pipe; group energy; outdoor air temperature; heat loss; heating load; supply water; heat supply; household; DISTRICT; SYSTEM; OPTIMIZATION; CONSUMPTION; SIMULATION; MODEL;
D O I
10.3390/en5051686
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.
引用
收藏
页码:1686 / 1704
页数:19
相关论文
共 7 条
  • [1] Study on the optimal heat supply control algorithm for district heating distribution network in response to outdoor air temperature
    Byun, Sun-Joon
    Park, Hyun-Sik
    Yi, Sung-Jae
    Song, Chul-Hwa
    Choi, Young-Don
    Lee, So-Hyeon
    Shin, Jong-Keun
    [J]. ENERGY, 2015, 86 : 247 - 256
  • [2] Operation Parameters Variation of Air Source Heat Pump According to the Outdoor Temperature
    Sezen, Kutbay
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (03): : 1179 - 1184
  • [3] Application of genetic algorithm to the optimal-chilled water supply temperature calculation of air-conditioning systems for saving energy
    Chang, Yung-Chung
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (08) : 796 - 810
  • [4] Development of a variable water temperature control method for air source heat pump based on the supply-demand balance
    Sun, Yuying
    Li, Xintian
    Wei, Wenzhe
    Xue, Huiyu
    Wang, Wei
    Deng, Shiming
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [5] Evaluation of Building Energy Saving Through the Development of Venetian Blinds’ Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio
    Hyuk Ju Kwon
    Sang Hun Yeon
    Keum Ho Lee
    Kwang Ho Lee
    [J]. International Journal of Thermophysics, 2018, 39
  • [6] Evaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio
    Kwon, Hyuk Ju
    Yeon, Sang Hun
    Lee, Keum Ho
    Lee, Kwang Ho
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2018, 39 (02)
  • [7] DESIGN OF NEARLY ZERO ENERGY BUILDINGS COUPLED WITH AN EARTH TO AIR HEAT EXCHANGER IN MEDITERRANEAN CLIMATE: DEVELOPMENT OF AN ANALYTIC MODEL AND VALIDATION AGAINST A MONITORED CASE STUDY
    Pagliano, Lorenzo
    Zangheril, Paolo
    [J]. BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 3706 - 3711