DESIGN OF NEARLY ZERO ENERGY BUILDINGS COUPLED WITH AN EARTH TO AIR HEAT EXCHANGER IN MEDITERRANEAN CLIMATE: DEVELOPMENT OF AN ANALYTIC MODEL AND VALIDATION AGAINST A MONITORED CASE STUDY
被引:0
|
作者:
Pagliano, Lorenzo
论文数: 0引用数: 0
h-index: 0
机构:
Politecn Milan, End Use Efficiency Res Grp eERG PoliMI, Milan, ItalyPolitecn Milan, End Use Efficiency Res Grp eERG PoliMI, Milan, Italy
Pagliano, Lorenzo
[1
]
Zangheril, Paolo
论文数: 0引用数: 0
h-index: 0
机构:
Politecn Milan, End Use Efficiency Res Grp eERG PoliMI, Milan, ItalyPolitecn Milan, End Use Efficiency Res Grp eERG PoliMI, Milan, Italy
Zangheril, Paolo
[1
]
机构:
[1] Politecn Milan, End Use Efficiency Res Grp eERG PoliMI, Milan, Italy
At the Passivhaus of Cherasco, located in Pianura Padana (Italy), an earth to air heat exchanger (EAHE) and natural night ventilation (in summer) are used to deliver comfort conditions with very low energy consumption. One year and a half of continuous measurements have been carried out in order to evaluate the energy and comfort performances of this building, which combines the Passivhaus concept with local architectural solutions. We present an analysis of the system constituted by building envelope and EAHE. Monitored data (with a particular focus on cooling potential) were evaluated with the use of established indicators and compared with simulations performed by coupling dynamic simulation software (EnergyPlus) and an analytic model for the EAHE. Based on this analysis a simplified steady-periodic model is developed to provide an estimate of the behaviour of the coupled system building envelope (including night ventilation) and EAHE from the point of view of energy and comfort, over a period of few weeks. The model is validated towards monitored data and shows a good agreement in terms of temperature profile, with a slight phase discrepancy, as expected based on the simplifying assumptions about thermal capacity effects. The analytic model is proposed as a tool for (i) evaluating the integration of EAHEs during the early design phase and (ii) optimise their operation under variable weather and occupation conditions, via incorporation in the control software of the building.
机构:
Islamic Azad Univ, Dept Mech Engn, Shahrekord Branch, Shahrekord, IranYazd Univ, Ind Engn Dept, Yazd, Iran
Jahangiri, Mehdi
Sedaghat, Ahmad
论文数: 0引用数: 0
h-index: 0
机构:
Australian Coll Kuwait, Sch Engn, Dept Mech Engn, Kuwait, KuwaitYazd Univ, Ind Engn Dept, Yazd, Iran
Sedaghat, Ahmad
Norouzianpour, Hirbod
论文数: 0引用数: 0
h-index: 0
机构:
Univ New Mexico, Sch Architecture & Planning, Albuquerque, NM 87131 USAYazd Univ, Ind Engn Dept, Yazd, Iran
Norouzianpour, Hirbod
Chowdhury, Shahariar
论文数: 0引用数: 0
h-index: 0
机构:
Prince Songkla Univ, Fac Environm Management, Hat Yai 90112, Songkhla, Thailand
Prince Songkla Univ, Fac Environm Management, Environm Assessment & Technol Hazardous Waste Man, Hat Yai, ThailandYazd Univ, Ind Engn Dept, Yazd, Iran
Chowdhury, Shahariar
论文数: 引用数:
h-index:
机构:
Techato, Kuaanan
论文数: 引用数:
h-index:
机构:
Issakhov, Alibek
Almutairi, Khalid
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hafr Al Batin, Community Coll, Mech Engn Technol, Hafar al Batin, Saudi ArabiaYazd Univ, Ind Engn Dept, Yazd, Iran