The effects of pulse rate, artefact and pulse strength on oscillometric non-invasive blood pressure measurements.

被引:0
|
作者
Amoore, JN [1 ]
Geake, WB [1 ]
Scott, DHT [1 ]
机构
[1] Royal Infirm, Dept Med Phys & Med Engn, Edinburgh EH3 9YW, Midlothian, Scotland
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We examined the effects of pulse rate, pulse and artefact on 20 adult oscillometric non-invasive blood pressure measurements using NIBP test simulators. Over a range of pulse rates from 40 to 200 bpm the 20 NIBP monitors studied recorded little change in registered pressures. The monitors achieved consistent readings at low pulse rates by decreasing the deflation rate and hence increasing the determination time (from under 20 sec at 200 bpm to over 30 sec at 40 bpm). High levels of artefact produced artificially high systolic pressures in 12 of the 16 monitors that recorded pressures, 6 of them being over 30 mmHg above the target 120 mmHg; 4 of the monitors signalled failure to record due to excessive artefact. Pulse strengths of 25% of the nominal were coped with well by most monitors with a slight tendency for the monitors to record low systolic pressures.
引用
收藏
页码:1977 / 1978
页数:2
相关论文
共 50 条
  • [31] Non-invasive blood pressure monitoring in dialysis patients using pulse wave velocity
    Koball, Sebastian
    Hermann, Hans
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [32] Pulse Transition Characterization from Electrocardiography and Photoplethysmography for Non-Invasive Blood Pressure Estimation
    Mohammed, Hazem
    Wu, Hao
    Wang, Guoxing
    2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 2841 - 2845
  • [33] Methods for Continuous Non-invasive Measurement of Blood Pressure: Pulse Transit Time a Review
    Kaur, Harleen
    Bhutto, Javed Khan
    Choudhary, Bhawani Shankar
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (03) : S863 - S872
  • [34] Continuous non-invasive blood pressure during continuous repositioning by pulse transit time
    Jeong, Hieyong
    Yoshimoto, Kayo
    Wang, Tianyi
    Ohno, Takafumi
    Yamada, Kenji
    Kido, Michiko
    Ohno, Yuko
    COGENT ENGINEERING, 2016, 3 (01):
  • [35] A non-invasive blood pressure prediction method based on pulse wave feature fusion
    Yan, Jianjun
    Cai, Xianglei
    Zhu, Guangyao
    Guo, Rui
    Yan, Haixia
    Wang, Yiqin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 74
  • [36] Non-invasive Blood Pressure Measurement by Pulse Wave Analysis Using FBG Sensor
    Katsuragawa, Yui
    Ishizawa, Hiroaki
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 511 - 515
  • [37] Non-invasive blood pressure data acquisition employing pulse transit time detection
    Kerola, J
    Kontra, V
    Sepponen, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1308 - 1309
  • [38] Pulse arrhythmia diagnosis by oscillometric blood pressure measurement
    Forstner, KW
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 48A - 48A
  • [39] Blood Pressure Estimation using Oscillometric Pulse Morphology
    Mafi, Majid
    Rajan, Sreeraman
    Bolic, Miodrag
    Groza, Voicu Z.
    Dajani, Hilmi R.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2492 - 2496
  • [40] Comparison of non-invasive and invasive blood pressure measurements in horses during anaesthesia using the oscillometric blood pressure monitor S/5 Datex Ohmeda
    Fouche, Nathalie
    Auer, Ulrike
    Iff, Isabelle
    PFERDEHEILKUNDE, 2016, 32 (05): : 479 - 484