Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography

被引:29
|
作者
Aufrichtig, R
Xue, P
机构
[1] Perkin Elmer, GE Med Syst, Xray Detector Engn, Santa Clara, CA 95054 USA
[2] GE Med Syst, Xray Syst Engn, Milwaukee, WI USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 09期
关键词
D O I
10.1088/0031-9155/45/9/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of dose reduction on low-contrast detectability is investigated theoretically and experimentally for a production grade amorphous silicon (a-Si) x-ray detector and compared with a standard thoracic screen-film combination. A non-prewhitening matched filter observer model modified to include a spatial response function and internal noise for the human visual system (HVS) is used to calculate a signal-to-noise ratio (SNR) related to object detectability. Other inputs to the SNR calculation are the detective quantum efficiency (DQE) and the modulation transfer function (MTF) of the imaging system. Besides threshold detectability, the model predicts the equivalent perception dose ratio (EPDR), which is the fraction of the screen-him exposure for which the digital detector provides equal detectability. Images of a contrast-detail phantom are obtained with the digital detector at dose levels corresponding to 27%, 41%, 63% and 100% of the dose used for screen-film. The images are used in a four-alternative forced choice (4-AFC) observer perception study in order to measure threshold detectability. A statistically significant improvement in contrast detectability is measured with the digital detector at 100% and 63% of the screen-film dose. There is no statistical difference between screen-film and digital at 41% of the dose. On average, the experimental EPDR is 44%, which agrees well with the model prediction of 40%.
引用
收藏
页码:2653 / 2669
页数:17
相关论文
共 50 条
  • [11] Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography -: Effect of dose reduction on the detectability of cortical bone defects and fractures
    Strotzer, M
    Gmeinwieser, J
    Spahn, M
    Völk, M
    Fründ, R
    Seitz, J
    Spies, V
    Alexander, J
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 1998, 33 (01) : 33 - 38
  • [12] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266
  • [13] Motion measurements in low-contrast X-ray imagery
    Berger, M
    Gerig, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 832 - 841
  • [14] Low Dose Digital X-ray Imaging With Avalanche Amorphous Selenium
    Scheuermann, James R.
    Goldan, Amir H.
    Tousignant, Olivier
    Leveille, Sebastien
    Zhao, Wei
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [15] Optimum phase condition for low-contrast X-ray masks
    Fujii, K
    Suzuki, K
    Matsui, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (12B): : 7076 - 7079
  • [16] Optimum phase condition for low-contrast X-ray masks
    Fujii, Kiyoshi
    Suzuki, Katsumi
    Matsui, Yasuji
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (12 B): : 7076 - 7079
  • [17] USE OF EGS4 FOR THE EVALUATION OF THE PERFORMANCE OF A SILICON DETECTOR FOR X-RAY DIGITAL RADIOGRAPHY
    BENCIVELLI, W
    BERTOLUCCI, E
    BOTTIGLI, U
    DELGUERRA, A
    MAZZEI, D
    MESSINEO, A
    NELSON, WR
    RANDACCIO, P
    ROSSO, V
    RUSSO, P
    STEFANINI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (03): : 574 - 580
  • [18] Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    Aufrichtig, R
    MEDICAL PHYSICS, 1999, 26 (07) : 1349 - 1358
  • [19] X-ray tests of a microchannel plate detector and amorphous silicon pixel array readout for neutron radiography
    Ambrosi, R. M.
    Street, R.
    Feller, B.
    Fraser, G. W.
    Watterson, J. I. W.
    Lanza, R. C.
    Dowson, J.
    Ross, D.
    Martindale, A.
    Abbey, A. F.
    Vernon, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 844 - 852
  • [20] A new index for low-contrast detectability based on the radiation dose and measurements
    Okumura, M
    Kazama, M
    Nobuta, Y
    Rifu, T
    Tsukagoshi, S
    Muramatsu, Y
    RADIOLOGY, 2001, 221 : 366 - 367