Laser Doppler flowmetry: Characteristics of a modified single-fibre technique

被引:4
|
作者
Cai, H [1 ]
Rohman, H [1 ]
Larsson, SE [1 ]
Oberg, PA [1 ]
机构
[1] LINKOPING UNIV,DEPT ORTHOPAED,S-58185 LINKOPING,SWEDEN
关键词
iso-irradiance; laser beam; modified single fibre; ray tracing;
D O I
10.1007/BF02637015
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The single-fibre percutaneous laser Doppler technique has been used in previous studies of intramuscular blood flow. This method facilitates studies of blood flow in deep tissue volumes and minimises the tissue trauma. The technique has been further developed with the aim of improving the signal quality. This has been accomplished by modifying the geometry of the fibre tip. By melting the fibre core material, lenses of different shapes are formed. Flat, spherical and 'pear'-type tips have been manufactured and are evaluated theoretically and experimentally. The paraxial theory cannot accurately predict the position of zones of highest irradiance. Therefore, a ray-tracing program has been developed in the C language, by means of which some of the optical properties of the modified fibre tips can be simulated, Isoirradiance graphs and beam profiles are calculated for the three different fibre tips, Measured and calculated irradiance curves are used for evaluation of the properties of the ray-tracing model. The three types of fibre tips are also evaluated and compared in flow models. The sphere and pear-type probes show a higher flow sensitivity than the flat-end type, These improvements in flow sensitivity are interpreted as being related to the larger, strongly irradiated tissue volumes in front of the fibres. Intramuscular measurements with the pear-type probe show high sensitivities to induced blood flow changes.
引用
收藏
页码:2 / 8
页数:7
相关论文
共 50 条
  • [31] Laser Doppler flowmetry technique for studying hemodynamics of the human small intestine.
    Thollander, M
    Hellstrom, PM
    Svensson, TH
    Gazelius, B
    GASTROENTEROLOGY, 1996, 110 (04) : A367 - A367
  • [32] LASER DOPPLER FLOWMETRY IN PERMANENT TEETH
    Cholakova, Radka
    JOURNAL OF IMAB, 2019, 25 (04): : 2751 - 2754
  • [33] Laser Doppler Flowmetry in the Microlymphodynamics Study
    Vasilev, P. V.
    Margaryants, N. B.
    Erofeev, N. P.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2019, 11 (02) : 92 - 96
  • [34] Scanning laser Doppler flowmetry in glaucoma
    Hollo, G
    vandenBerg, TJTP
    Greve, EL
    INTERNATIONAL OPHTHALMOLOGY, 1997, 20 (1-3) : 63 - 70
  • [35] EVALUATION OF CONTACT ALLERGY TO CHEMICALS USING LASER DOPPLER FLOWMETRY (LDF) TECHNIQUE
    QING, L
    AOYAMA, K
    MATSUSHITA, T
    CONTACT DERMATITIS, 1992, 26 (01) : 27 - 33
  • [36] Digital Laser Doppler Flowmetry: Device, Signal Processing Technique, and Clinical Testing
    Kozlov, I. O.
    Zherebtsov, E. A.
    Podmasteryev, K., V
    Dunaev, A., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 55 (01): : 12 - 16
  • [37] Variability of laser doppler flowmetry measurements
    Katz, BA
    Böhm, AG
    Pillunat, LE
    Richard, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S277 - S277
  • [38] LASER-DOPPLER FLOWMETRY IN NEUROSURGERY
    BOLOGNESE, P
    MILLER, JI
    HEGER, IM
    MILHORAT, TH
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1993, 5 (03) : 151 - 158
  • [39] Role of speckles in laser Doppler flowmetry
    Steenbergen, W
    de Mul, F
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS III, PROCEEDINGS OF, 1998, 3252 : 2 - 13
  • [40] Application of laser Doppler flowmetry in neurosurgery
    Arbit, E
    DiResta, GR
    NEUROSURGERY CLINICS OF NORTH AMERICA, 1996, 7 (04) : 741 - &