Laser Doppler flowmetry: Characteristics of a modified single-fibre technique

被引:4
|
作者
Cai, H [1 ]
Rohman, H [1 ]
Larsson, SE [1 ]
Oberg, PA [1 ]
机构
[1] LINKOPING UNIV,DEPT ORTHOPAED,S-58185 LINKOPING,SWEDEN
关键词
iso-irradiance; laser beam; modified single fibre; ray tracing;
D O I
10.1007/BF02637015
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The single-fibre percutaneous laser Doppler technique has been used in previous studies of intramuscular blood flow. This method facilitates studies of blood flow in deep tissue volumes and minimises the tissue trauma. The technique has been further developed with the aim of improving the signal quality. This has been accomplished by modifying the geometry of the fibre tip. By melting the fibre core material, lenses of different shapes are formed. Flat, spherical and 'pear'-type tips have been manufactured and are evaluated theoretically and experimentally. The paraxial theory cannot accurately predict the position of zones of highest irradiance. Therefore, a ray-tracing program has been developed in the C language, by means of which some of the optical properties of the modified fibre tips can be simulated, Isoirradiance graphs and beam profiles are calculated for the three different fibre tips, Measured and calculated irradiance curves are used for evaluation of the properties of the ray-tracing model. The three types of fibre tips are also evaluated and compared in flow models. The sphere and pear-type probes show a higher flow sensitivity than the flat-end type, These improvements in flow sensitivity are interpreted as being related to the larger, strongly irradiated tissue volumes in front of the fibres. Intramuscular measurements with the pear-type probe show high sensitivities to induced blood flow changes.
引用
收藏
页码:2 / 8
页数:7
相关论文
共 50 条
  • [21] RENAL MICROVASCULAR PERFUSION EVALUATED BY SINGLE FIBER LASER DOPPLER FLOWMETRY
    LIEN, B
    NORSTEIN, J
    SALERUD, EG
    KVERNEBO, K
    FLATMARK, A
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1992, 11 (03): : 307 - 317
  • [22] Fibre fragment distribution in a single-fibre composite tension test
    Andersons, J
    Joffe, R
    Hojo, M
    Ochiai, S
    COMPOSITES PART B-ENGINEERING, 2001, 32 (04) : 323 - 332
  • [23] Penetration depth of scanning laser Doppler flowmetry and laser Doppler flowmetry in the human optic nerve head
    Böhm, AG
    Kuba, GB
    Pillunat, LE
    Richard, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S779 - S779
  • [24] A modified fast laser-Doppler flowmetry to measure the pulsatile microcirculation in rats
    Jan, MY
    Hsiu, H
    Wang, YYL
    Wang, WK
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 415 - 416
  • [25] Analysis and evaluation of the single-fibre fragmentation test
    Copponnex, TJ
    COMPOSITES SCIENCE AND TECHNOLOGY, 1996, 56 (08) : 893 - 909
  • [26] Speckles in laser Doppler blood flowmetry
    Serov, A
    Steenbergen, W
    de Mul, F
    SARATOV FALL MEETING 2000: COHERENT OPTICS OF ORDERED AND RANDOM MEDIA, 2001, 4242 : 306 - 318
  • [27] Laser Doppler flowmetry in endodontics: a review
    Jafarzadeh, H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (06) : 476 - 490
  • [28] LASER DOPPLER FLOWMETRY IN ARTERIAL RECONSTRUCTION
    JANSSON, I
    ELFSTROM, J
    THROMBOSIS AND HAEMOSTASIS, 1989, 62 (01) : 574 - 574
  • [29] Laser Doppler flowmetry in asymmetric glaucoma
    Lam, A
    Piltz-Seymour, JR
    DuPont, J
    Grunwald, JE
    CURRENT EYE RESEARCH, 2005, 30 (03) : 221 - 227
  • [30] Digital Laser Doppler Flowmetry: Device, Signal Processing Technique, and Clinical Testing
    I. O. Kozlov
    E. A. Zherebtsov
    K. V. Podmasteryev
    A. V. Dunaev
    Biomedical Engineering, 2021, 55 : 12 - 16