MRI Image Distortion due to Magnetic Materials in Medical Implants

被引:0
|
作者
Harberts, Dick W. [1 ]
van Helvoort, Mark [2 ]
机构
[1] Philips Innovat Serv, Electromagnet Competence Ctr, Eindhoven, Netherlands
[2] Philips Healthcare, MRI Dev, Best, Netherlands
关键词
MRI; Magnetic Resonance Imaging; implants; COMPATIBILITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, research activities are underway to create coexistence between active implantable medical devices and Magnetic Resonance Imaging (MRI). One of the questions is if ferrite materials can be used for miniature transformers for EMI suppression. Commonly it is known that the use of magnetic materials should be minimized in and near an MRI scanner because MRI employs large magnetic fields with which any magnetic material will be subject to strong forces. In addition, magnetic materials may introduce image artifacts and reduce diagnostic image quality. The analysis presented in this paper shows that the requirements on diagnostic image quality pose higher limitations on the use of magnetic materials in medical implants than the requirements for magneto-mechanical forces. From experiments with ferrites in a 1.5-T MRI system, it is concluded that if diagnostic image quality is required for distances of at least 2 cm from the medical implant, then only 0.1 mm(3) ferrite can be accepted. This amount of ferrite is too low for any practical application. Therefore, medical implants can only be coexistent with MRI if they do not contain ferrites.
引用
收藏
页码:1463 / 1466
页数:4
相关论文
共 50 条
  • [1] Interactions of medical implants with the magnetic fields in MRI
    Nyenhuis, JA
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3767 - 3770
  • [2] Quantifying image distortion of orthopedic materials in magnetic resonance imaging
    Koff, Matthew F.
    Shah, Parina
    Koch, Kevin M.
    Potter, Hollis G.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 610 - 618
  • [3] MRI interactions with medical implants
    Nyenhuis, J
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2002, : 920 - 924
  • [4] Medical Implants: Time for the New Materials?
    Evans, Jon
    [J]. PLASTICS ENGINEERING, 2010, 66 (09) : 32 - 36
  • [5] MRI safety and compatibility of implants and medical devices
    Woods, TO
    [J]. STAINLESS STEELS FOR MEDICAL AND SURGICAL APPLICATIONS, 2003, 1438 : 82 - 90
  • [6] Techniques to demonstrate MRI safety of medical implants
    Oberle, Michael
    [J]. Microwave Journal, 2009, 52 (12): : 60 - 68
  • [7] TECHNIQUES TO DEMONSTRATE MRI SAFETY OF MEDICAL IMPLANTS
    Oberle, Michael
    [J]. MICROWAVE JOURNAL, 2009, 52 (12) : 60 - +
  • [8] Interaction of medical implants with the MRI electromagnetic fields
    Mohsin S.A.
    Nyenhuis J.
    Masood R.
    [J]. Progress In Electromagnetics Research C, 2010, 13 : 195 - 202
  • [9] Image distortion due to refraction by planar surfaces
    Arizaga, R.
    Cap, N.
    Rabal, H.
    Trivi, M.
    [J]. EUROPEAN JOURNAL OF PHYSICS, 2010, 31 (01) : 115 - 127
  • [10] Data distortion due to magnetic medium microstructure
    Glavinas, E
    Dhagat, P
    Jander, A
    Indeck, RS
    Muller, MW
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1997, 33 (02) : 1069 - 1072