MRI Image Distortion due to Magnetic Materials in Medical Implants

被引:0
|
作者
Harberts, Dick W. [1 ]
van Helvoort, Mark [2 ]
机构
[1] Philips Innovat Serv, Electromagnet Competence Ctr, Eindhoven, Netherlands
[2] Philips Healthcare, MRI Dev, Best, Netherlands
关键词
MRI; Magnetic Resonance Imaging; implants; COMPATIBILITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, research activities are underway to create coexistence between active implantable medical devices and Magnetic Resonance Imaging (MRI). One of the questions is if ferrite materials can be used for miniature transformers for EMI suppression. Commonly it is known that the use of magnetic materials should be minimized in and near an MRI scanner because MRI employs large magnetic fields with which any magnetic material will be subject to strong forces. In addition, magnetic materials may introduce image artifacts and reduce diagnostic image quality. The analysis presented in this paper shows that the requirements on diagnostic image quality pose higher limitations on the use of magnetic materials in medical implants than the requirements for magneto-mechanical forces. From experiments with ferrites in a 1.5-T MRI system, it is concluded that if diagnostic image quality is required for distances of at least 2 cm from the medical implant, then only 0.1 mm(3) ferrite can be accepted. This amount of ferrite is too low for any practical application. Therefore, medical implants can only be coexistent with MRI if they do not contain ferrites.
引用
收藏
页码:1463 / 1466
页数:4
相关论文
共 50 条
  • [31] Systematic spatial distortion in MRI due to gradient non-linearities
    Wald, L
    Schmitt, F
    Dale, A
    [J]. NEUROIMAGE, 2001, 13 (06) : S50 - S50
  • [32] Medical Image Denoising in MRI Reconstruction Procedure
    Han, Dong
    Velastegui, Ronny
    [J]. COMPUTATIONAL SCIENCE AND ITS APPLICATIONS, ICCSA 2021, PT II, 2021, 12950 : 115 - 130
  • [33] Distortion of SIMS profiles due to ion beam mixing: Shallow arsenic implants in silicon
    Montandon, C
    Bourenkov, A
    Frey, L
    Pichler, P
    Biersack, JP
    [J]. RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1998, 145 (03): : 213 - 223
  • [34] CMB distortion anisotropies due to the decay of primordial magnetic fields
    Miyamoto, Koichi
    Sekiguchi, Toyokazu
    Tashiro, Hiroyuki
    Yokoyama, Shuichiro
    [J]. PHYSICAL REVIEW D, 2014, 89 (06):
  • [35] Correcting Image Distortion for Brain Tumor Treatments on an MRI-Linac
    Shan, S.
    Waddington, D.
    Liu, P.
    Dong, B.
    Buckley, J.
    Elwadia, D.
    Pham, T.
    Liney, G.
    Keall, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [36] Distortion of the acoustic peaks in the CMBR due to a primordial magnetic field
    Adams, J
    Danielsson, UH
    Grasso, D
    Rubinstein, H
    [J]. PHYSICS LETTERS B, 1996, 388 (02) : 253 - 258
  • [37] Production of medical implants from titanium-base materials
    Il'in, A.A.
    Skvortsova, S.V.
    Mamonov, A.M.
    Karpov, V.N.
    [J]. Metally, 2002, (03): : 97 - 104
  • [38] Bio-Medical Materials in Human Joint Implants - A Review
    Hedia, Hassan S.
    Najjar, Ismail M. R.
    [J]. MATERIALS TESTING, 2011, 53 (05) : 266 - 279
  • [39] Design considerations for piezocomposite materials for electrical stimulation in medical implants
    Krech E.
    Haas E.
    Tideman G.
    Reinsch B.
    Friis E.
    [J]. Journal of Medical Engineering and Technology, 2022, 46 (05): : 402 - 414
  • [40] Simulation of Room Distortion On Measurements of RF Noise Due to a Medical Linac
    Lamey, M.
    Burke, B.
    Carlone, M.
    Rathee, S.
    Fallone, B.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2768 - +