MRI Image Distortion due to Magnetic Materials in Medical Implants

被引:0
|
作者
Harberts, Dick W. [1 ]
van Helvoort, Mark [2 ]
机构
[1] Philips Innovat Serv, Electromagnet Competence Ctr, Eindhoven, Netherlands
[2] Philips Healthcare, MRI Dev, Best, Netherlands
关键词
MRI; Magnetic Resonance Imaging; implants; COMPATIBILITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently, research activities are underway to create coexistence between active implantable medical devices and Magnetic Resonance Imaging (MRI). One of the questions is if ferrite materials can be used for miniature transformers for EMI suppression. Commonly it is known that the use of magnetic materials should be minimized in and near an MRI scanner because MRI employs large magnetic fields with which any magnetic material will be subject to strong forces. In addition, magnetic materials may introduce image artifacts and reduce diagnostic image quality. The analysis presented in this paper shows that the requirements on diagnostic image quality pose higher limitations on the use of magnetic materials in medical implants than the requirements for magneto-mechanical forces. From experiments with ferrites in a 1.5-T MRI system, it is concluded that if diagnostic image quality is required for distances of at least 2 cm from the medical implant, then only 0.1 mm(3) ferrite can be accepted. This amount of ferrite is too low for any practical application. Therefore, medical implants can only be coexistent with MRI if they do not contain ferrites.
引用
收藏
页码:1463 / 1466
页数:4
相关论文
共 50 条
  • [21] Angioedema Due to Pear: Medical Image
    Cemil, Kavalci
    Fevzi, Yilmaz
    Ali, Demir
    [J]. JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 (01)
  • [22] CORRECTION METHOD OF IMAGE DISTORTION DUE TO NON-UNIFORMITY OF STATIC MAGNETIC-FIELD IN NMR IMAGING
    KAWANAKA, A
    TAKAGI, M
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 515 : 173 - 177
  • [23] Medical image application: Differentiate the MRI image by the image comparison technique
    Su, CL
    [J]. MACHINE VISION AND THREE-DIMENSIONAL IMAGING SYSTEMS FOR INSPECTION AND METROLOGY, 2001, 4189 : 63 - 71
  • [24] Technique to Assess the Compatibility of Medical Implants to the RF Field in MRI
    McCabe, Steven
    Scott, Jonathan
    [J]. 2015 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), VOLS 1-3, 2015,
  • [25] Futuristic medical implants using bioresorbable materials and devices
    Chatterjee, Suman
    Saxena, Mansi
    Padmanabhan, Deepak
    Jayachandra, Mahesh
    Pandya, Hardik J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 142
  • [26] INTERACTION OF METALLIC NEUROSURGICAL IMPLANTS WITH MAGNETIC-RESONANCE IMAGING AT 1.5 TESLA AS A CAUSE OF IMAGE DISTORTION AND OF HAZARDOUS MOVEMENT OF THE IMPLANT
    GO, KG
    KAMMAN, RL
    MOOYAART, EL
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 1989, 91 (02) : 109 - 115
  • [27] Applications of some biopolymeric materials as medical implants: An overview
    Bansal, Priya
    Katiyar, Deepti
    Prakash, Surya
    Rao, N. G. Raghavendra
    Saxena, Vidhu
    Kumar, Vinay
    Kumar, Abhishek
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 3377 - 3381
  • [28] Implementation of FPGA Algorithms for Identification of Image Distortion due to Compression
    Lysakov, K. F.
    Oblaukhov, K. K.
    Shadrin, M. Yu
    [J]. OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2020, 56 (01) : 28 - 32
  • [29] Implementation of FPGA Algorithms for Identification of Image Distortion due to Compression
    K. F. Lysakov
    K. K. Oblaukhov
    M. Yu. Shadrin
    [J]. Optoelectronics, Instrumentation and Data Processing, 2020, 56 : 28 - 32
  • [30] Spatial Distortion Due to Field Inhomogeneity in 3.0 Tesla Intraoperative MRI
    Choudhri, Asim F.
    Chin, Eric M.
    Klimo, Paul
    Boop, Frederick A.
    [J]. NEURORADIOLOGY JOURNAL, 2014, 27 (04): : 387 - 392