Need for Standardization: Influence of Artificial Canal Size on Cyclic Fatigue Tests of Endodontic Instruments

被引:9
|
作者
Buerklein, Sebastian [1 ]
Massmann, Paul [2 ]
Donnermeyer, David [2 ]
Tegtmeyer, Karsten [2 ]
Schaefer, Edgar [1 ]
机构
[1] Westphalian Wilhelms Univ, Cent Interdisciplinary Ambulance Sch Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
[2] Westphalian Wilhelms Univ, Dept Periodontol & Operat Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 11期
关键词
artificial canal; congruence; body temperature; dynamic fatigue tests; fracture resistance; ISO; nickel-titanium instruments; NICKEL-TITANIUM ROTARY; ROTATIONAL SPEED; RESISTANCE; SEPARATION; FILES; TEMPERATURE; FRACTURE; DEFECTS;
D O I
10.3390/app11114950
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim was to evaluate the influence of artificial canal size on the results of cyclic fatigue tests for endodontic instruments. Dynamic cyclic fatigue at body temperature using continuous tapered nickel-titanium F6-SkyTaper instruments (Komet, Lemgo, Germany), size 25/.06 with an amplitude of 3 mm, was tested in four different simulated root canals: (A) size of the instrument +0.02 mm (within the tolerances of the instruments); (B) +0.05 mm; (C) +0.10 mm; (D) parallel tube with 1.25 mm in diameter. The artificial canals (angle of curvature 60 degrees, radius 5.0 mm, center of curvature 5.0 mm) were produced by a LASER-melting technique. Time and cycles to fracture, and lengths of the fractured instruments were recorded and statistically analyzed (Student-Newman-Keuls; Kruskal-Wallis test). Time to fracture significantly increased with increasing size of the artificial canals in the following order: A < B, C < D (p < 0.05). Length of separated instruments continuously decreased with increasing canal sizes. The parallel tube produced the significantly shortest fragments (p < 0.05). Within the limitations of this study, dynamic cyclic fatigue of endodontic instruments depends on the congruency of the instruments' dimensions with that of the artificial canals. In future cyclic fatigue testing, due to the closer match of canal and instrument parameters, it is necessary to adjust the artificial canal sizes to the size of the instruments within the manufacturing tolerances of the instruments.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Influence of Continuous Rotation and Optimal Torque Reverse Kinematics on the Cyclic Fatigue Strength of Endodontic NiTi Clockwise Cutting Rotary Instruments
    Martins, Jorge N. R.
    Silva, Emmanuel J. N. L.
    Marques, Duarte
    Versiani, Marco A.
    DENTISTRY JOURNAL, 2024, 12 (10)
  • [42] Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments
    Pedulla, E.
    Lo Savio, F.
    Boninelli, S.
    Plotino, G.
    Grande, N. M.
    Rapisarda, E.
    La Rosa, G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (11) : 1043 - 1050
  • [43] Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    Haïkel, Y
    Serfaty, R
    Bateman, G
    Senger, B
    Allemann, C
    JOURNAL OF ENDODONTICS, 1999, 25 (06) : 434 - 440
  • [44] Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue
    Stojanac, Igor
    Drobac, Milan
    Petrovic, Ljubomir
    Atanackovic, Teodor
    DENTAL MATERIALS JOURNAL, 2012, 31 (04) : 650 - 655
  • [45] Cyclic fatigue comparison among endodontic instruments with similar cross section and different surface coating
    Pedulla, Eugenio
    Plotino, Gianluca
    Scibilia, Mauro
    Grande, Nicola M.
    De Santis, Danicle
    Pardo, Alessia
    Testarelli, Luca
    Gambarini, Gianluca
    MINERVA STOMATOLOGICA, 2019, 68 (02): : 67 - 73
  • [46] Application of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments
    Li, Uei-Ming
    Shin, Chow-g Shin
    Lan, Wan-Hong
    Lin, Chun-Pin
    DENTAL MATERIALS JOURNAL, 2006, 25 (02) : 247 - 252
  • [47] Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation
    Wang, Zhuyu
    Zhang, Wen
    Zhang, Xiaolei
    PLOS ONE, 2016, 11 (08):
  • [48] Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments
    Gabiana Rodrigues Freitas
    Thais Marchand Ribeiro
    Fabiana Soares Grecca Vilella
    Tiago André Fontoura de Melo
    Clinical Oral Investigations, 2021, 25 : 469 - 475
  • [49] Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments
    Freitas, Gabiana Rodrigues
    Ribeiro, Thais Marchand
    Vilella, Fabiana Soares Grecca
    de Melo, Tiago Andre Fontoura
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (02) : 469 - 475
  • [50] Dynamic or static cyclic fatigue tests: which best determines the lifespan of endodontic files?
    Gambarra-Soares, Thaiane
    Lopes, Helio Pereira
    Machado Oliveira, Julio Cezar
    Souza, Leticia Chaves
    Leal Vieira, Victor Talarico
    Elias, Carlos Nelson
    ENDO-ENDODONTIC PRACTICE TODAY, 2013, 7 (02): : 101 - 104