Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments

被引:12
|
作者
Freitas, Gabiana Rodrigues [1 ]
Ribeiro, Thais Marchand [1 ]
Vilella, Fabiana Soares Grecca [2 ]
de Melo, Tiago Andre Fontoura [2 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Coll Dent, Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Endodont Div, Dept Conservat Dent, Rua Ramiro Barcelos,2492 Bairro Santana, BR-90035003 Porto Alegre, RS, Brazil
[3] Univ Fed Rio Grande do Sul, Fac Odontol, Dept Odontol Conservadora, Rua Ramiro Barcelos,2492 Bairro Santana, BR-90035003 Porto Alegre, RS, Brazil
关键词
Endodontic access; Minimally invasive; Nickel-titanium instruments; Root canal preparation; Microcomputed tomography; NICKEL-TITANIUM; CENTRING ABILITY; SHAPING ABILITY; TOMOGRAPHIC EVALUATION; APICAL TRANSPORTATION; EFFICACY; SYSTEMS; TEETH; STRAIGHT; PROTAPER;
D O I
10.1007/s00784-020-03390-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective This study evaluates whether endodontic cavity access into molars influences the chemomechanical preparation of curved root canals. Materials and methods Twenty mesiobuccal canals of maxillary molars were randomly divided into two experimental groups (n= 10), according to the type of endodontic access analyzed (conventional and minimally invasive). The preparations were made by a single operator, and the canals, after access, were prepared with Logic system (0.25, 0.04 taper) along the working length. Samples were scanned before and after canal preparation (SMX-90CT Plus (Shimadzu (R) microtomograph operated with 70 kV, 100 uA, FOV (XY) 13.3 mm, FOV (Z) 7.0 mm, and voxel size 0.013 mm/Pix)) to match canal volumes. Images were analyzed to evaluate surface areas, transport, and centralization at 3 mm from the canal entrance and 3 mm from the apex (OnDemand3D(TM)Dental software). Student'sttest with a significance level of 5% was used for the statistical analysis. Results Regardless of the position of the analyzed canals, there was no difference in the prepared area regarding the transport and centralization of the endodontic instrument between the two types of cavity accesses performed. Conclusions The conventional and minimally invasive access did not influence the action of the 0.25 and 0.04 taper instrument during the curved root canal preparation.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [1] Influence of endodontic cavity access on curved root canal preparation with ProDesign Logic rotary instruments
    Gabiana Rodrigues Freitas
    Thais Marchand Ribeiro
    Fabiana Soares Grecca Vilella
    Tiago André Fontoura de Melo
    [J]. Clinical Oral Investigations, 2021, 25 : 469 - 475
  • [2] Ultrastructural analysis of the root canal walls after preparation with two rotary nickel-titanium endodontic instruments
    Poggio, Claudio
    Dagna, Alberto
    Chiesa, Marco
    Beltrami, Riccardo
    Colombo, Marco
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2014, 5 (03) : 357 - 360
  • [3] Endodontic instruments for root canal therapy
    Lyon, KF
    [J]. CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2001, 16 (03): : 139 - 150
  • [4] Influence of operator expertise on glide path and root canal preparation of curved root canals with rotary and reciprocating motions
    Belen Dablanca-Blanco, Ana
    Arias, Ana
    Jose Ginzo-Villamayor, Maria
    Consuelo Perez, Maria
    Castelo-Baz, Pablo
    Martin-Biedma, Benjamin
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (01) : 37 - 43
  • [5] Comparison among Manual Instruments and Path File and Mtwo Rotary Instruments to Create a Glide Path in the Root Canal Preparation of Curved Canals
    Alves, Vanessa de Oliveira
    da Silveira Bueno, Carlos Eduardo
    Cunha, Rodrigo Sanches
    Pinheiro, Sergio Luiz
    Fontana, Carlos Eduardo
    de Martin, Alexandre Sigrist
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (01) : 117 - 120
  • [6] An analytical mechanical model to describe the response of NiTi rotary endodontic files in a curved root canal
    Francoise Leroy, Agnes Marie
    de Azevedo Bahia, Maria Guiomar
    Ehrlacher, Alain
    Lopes Buono, Vicente Tadeu
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (06): : 1594 - 1600
  • [7] The influence of different root canal open access shapes on the use of rotary root canal enlargement
    Hou, Ta-Ya
    Kao, Chuan-Yi
    Kao, Chia-Tze
    Huang, Tsui-Hsein
    [J]. JOURNAL OF DENTAL SCIENCES, 2024, 19 (03) : 1396 - 1409
  • [8] Comparison of root canal preparation with two rotary NiTi instruments:: ProFile .04 and GT Rotary
    Roedig, T.
    Huelsmann, M.
    Kahlmeier, C.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (07) : 553 - 562
  • [9] Design features of rotary root canal instruments
    Rzhanov, Evgueniy A.
    Belyaeva, Tatiana S.
    [J]. ENDO-ENDODONTIC PRACTICE TODAY, 2012, 6 (01): : 29 - 39
  • [10] Influence of Contracted Endodontic Access on Root Canal Geometry: An In Vitro Study
    Alovisi, Mario
    Pasqualini, Damiano
    Musso, Edoardo
    Bobbio, Elena
    Giuliano, Carlotta
    Mancino, Davide
    Scotti, Nicola
    Berutti, Elio
    [J]. JOURNAL OF ENDODONTICS, 2018, 44 (04) : 614 - 620