Need for Standardization: Influence of Artificial Canal Size on Cyclic Fatigue Tests of Endodontic Instruments

被引:9
|
作者
Buerklein, Sebastian [1 ]
Massmann, Paul [2 ]
Donnermeyer, David [2 ]
Tegtmeyer, Karsten [2 ]
Schaefer, Edgar [1 ]
机构
[1] Westphalian Wilhelms Univ, Cent Interdisciplinary Ambulance Sch Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
[2] Westphalian Wilhelms Univ, Dept Periodontol & Operat Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 11期
关键词
artificial canal; congruence; body temperature; dynamic fatigue tests; fracture resistance; ISO; nickel-titanium instruments; NICKEL-TITANIUM ROTARY; ROTATIONAL SPEED; RESISTANCE; SEPARATION; FILES; TEMPERATURE; FRACTURE; DEFECTS;
D O I
10.3390/app11114950
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim was to evaluate the influence of artificial canal size on the results of cyclic fatigue tests for endodontic instruments. Dynamic cyclic fatigue at body temperature using continuous tapered nickel-titanium F6-SkyTaper instruments (Komet, Lemgo, Germany), size 25/.06 with an amplitude of 3 mm, was tested in four different simulated root canals: (A) size of the instrument +0.02 mm (within the tolerances of the instruments); (B) +0.05 mm; (C) +0.10 mm; (D) parallel tube with 1.25 mm in diameter. The artificial canals (angle of curvature 60 degrees, radius 5.0 mm, center of curvature 5.0 mm) were produced by a LASER-melting technique. Time and cycles to fracture, and lengths of the fractured instruments were recorded and statistically analyzed (Student-Newman-Keuls; Kruskal-Wallis test). Time to fracture significantly increased with increasing size of the artificial canals in the following order: A < B, C < D (p < 0.05). Length of separated instruments continuously decreased with increasing canal sizes. The parallel tube produced the significantly shortest fragments (p < 0.05). Within the limitations of this study, dynamic cyclic fatigue of endodontic instruments depends on the congruency of the instruments' dimensions with that of the artificial canals. In future cyclic fatigue testing, due to the closer match of canal and instrument parameters, it is necessary to adjust the artificial canal sizes to the size of the instruments within the manufacturing tolerances of the instruments.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Influence of the Geometry of Curved Artificial Canals on the Fracture of Rotary Nickel-Titanium Instruments Subjected to Cyclic Fatigue Tests
    Lopes, Helio P.
    Vieira, Marcia V. B.
    Elias, Carlos N.
    Goncalves, Lucio S.
    Siqueira, Jose F., Jr.
    Moreira, Edson J. L.
    Vieira, Victor T. L.
    Souza, Leticia C.
    JOURNAL OF ENDODONTICS, 2013, 39 (05) : 704 - 707
  • [22] Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro
    Buerklein, Sebastian
    Massmann, Paul
    Schaefer, Edgar
    Donnermeyer, David
    MATERIALS, 2024, 17 (04)
  • [23] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [24] Location of the canal curvature and its influence on the resistance to fatigue fracture of two rotary nickel-titanium endodontic instruments
    Lopes, Helio P.
    Vieira, Marcia V. B.
    Elias, Carlos N.
    Siqueira, Jose F., Jr.
    Goncalves, Lucio S.
    Vieira, Victor T. L.
    ENDO-ENDODONTIC PRACTICE TODAY, 2013, 7 (01): : 53 - 58
  • [25] Influence of NiTi Wire Diameter on Cyclic and Torsional Fatigue Resistance of Different Heat-Treated Endodontic Instruments
    Pedulla, Eugenio
    Canova, Francesco Saverio
    La Rosa, Giusy Rita Maria
    Naaman, Alfred
    Diemer, Franck
    Generali, Luigi
    Nehme, Walid
    MATERIALS, 2022, 15 (19)
  • [26] Cyclic Fatigue Resistance of Three Different Rotary Endodontic Instruments with Design Modification
    Abu Naila, Ali S.
    Al-Huwaizi, Hussain F.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (08):
  • [27] The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments
    Dosanjh, Amandeep
    Paurazas, Susan
    Askar, Mazin
    JOURNAL OF ENDODONTICS, 2017, 43 (05) : 823 - 826
  • [28] Correlation between cyclic fatigue and the bending properties of nickel titanium endodontic instruments
    Pia, Jindan
    Miyara, Kana
    Ebihara, Arata
    Nomura, Naoyuki
    Hanawa, Takao
    Suda, Hideaki
    DENTAL MATERIALS JOURNAL, 2014, 33 (04) : 539 - 544
  • [29] Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    Mize, SB
    Clement, DJ
    Pruett, JP
    Carnes, DL
    JOURNAL OF ENDODONTICS, 1998, 24 (12) : 843 - 847
  • [30] Effect of Core Mass and Alloy on Cyclic Fatigue Resistance of Different Nickel-Titanium Endodontic Instruments in Matching Artificial Canals
    Buerklein, Sebastian
    Zupanc, Lennart
    Donnermeyer, David
    Tegtmeyer, Karsten
    Schaefer, Edgar
    MATERIALS, 2021, 14 (19)