Developing a dual energy x-ray absorptiometry (DEXA) system using SrI2:Eu2+ coupled to silicon photomultiplier (SiPM)

被引:0
|
作者
Matei, Liviu [1 ]
Groza, Michael [2 ]
Gomez, Michelle [1 ]
Espinoza, Kricia Ruano [1 ]
Buliga, Vladimir [1 ]
Burger, Arnold [1 ]
机构
[1] Fisk Univ, Dept Phys, 1000 17th Ave North, Nashville, TN 37208 USA
[2] 2716 E Castleberg Loop, Nampa, ID 83686 USA
基金
美国国家科学基金会;
关键词
Bone Mineral Density; SrI2:Eu2+; Silicon Photomultiplier; Osteoporosis;
D O I
10.1117/12.2567674
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the evaluation of an alternative solution for detectors of dual energy x-ray absorptiometry systems. Bone mineral density (BMD) evaluation tools are crucial to the proper diagnosis of osteoporosis. The commercially available DEXA systems utilize CZT as the detector of the small dose of ionizing radiation passing through the area of interest. Our paper presents a novel Strontium Iodide doped with Europium (SrI2:Eu2+) scintillator crystal coupled to a Silicon Photomultiplier (SiPM) array as a less expensive alternative to CZT detector. Dual energy (60 keV and 122 keV) exposure was used for BMD measurements of a bone phantoms containing CaHPO4 to mimic bone and resin to mimic soft tissue. Calibration curves was determined for both BMD and for thickness measurements, validated by "unknown" phantoms. Both calibration curves lead to decreased errors compared to commercially available systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Reliability of 2 Different Positioning Protocols for Dual-Energy X-ray Absorptiometry Measurement of Body Composition in Healthy Adults
    Kerr, Ava
    Slater, Gary J.
    Byrne, Nuala
    Nana, Alisa
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (03) : 282 - 289
  • [32] Combined Rietveld refinement of CaMgSi2O6:Eu2+ using X-ray and neutron powder diffraction data
    Yong-Il Kim
    Won Bin Im
    Duk Young Jeon
    Journal of Materials Science, 2006, 41 : 1643 - 1647
  • [33] Combined Rietveld refinement of CaMgSi2O6:Eu2+ using X-ray and neutron powder diffraction data
    Kim, YI
    Im, WB
    Jeon, DY
    JOURNAL OF MATERIALS SCIENCE, 2006, 41 (05) : 1643 - 1647
  • [34] Dual energy X-ray absorptiometry assessment of bone mass, fat mass distribution in type 2 diabetes mellitus men
    Shepelkevich, A.
    Pletneva, E.
    Vadzianava, V.
    Vasilieva, N.
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2012, 28 : 115 - 115
  • [35] Quantitative Comparison of 2 Dual-Energy X-ray Absorptiometry Systems in Assessing Body Composition and Bone Mineral Measurements
    Xu, Wenhua
    Chafi, Hatim
    Guo, Beibei
    Heymsfield, Steven B.
    Murray, Kori B.
    Zheng, Jolene
    Jia, Guang
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (03) : 298 - 304
  • [36] Structural refinement of BaMgAl10O17:: Eu2+ using X-ray and neutron powder diffraction
    Kim, YI
    Kang, SO
    Lee, JS
    Jung, MJ
    Kim, KH
    JOURNAL OF MATERIALS SCIENCE LETTERS, 2002, 21 (03) : 219 - 222
  • [37] Factors that determine body composition of female systemic lupus erythematosus (SLE) patients in Sri Lanka: a comparative study using dual-energy x-ray absorptiometry
    Liyanage, A.
    Lekamwasam, S.
    Dissanayake, S. P.
    Munidasa, D.
    LUPUS, 2013, 22 (09) : 972 - 976
  • [38] HIGH BONE MINERAL DENSITY AND OSTEOPOROSIS IN MEN WITH TYPE 2 DIABETES REFERRED FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY SCAN
    Salamat, Mohammad Reza
    Salamat, Amir Hossein
    Dashti, Gholam Reza
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 : 653 - 654
  • [39] Computer-Aided Detection of Incidental Lumbar Spine Fractures from Routine Dual-Energy X-Ray Absorptiometry (DEXA) Studies Using a Support Vector Machine (SVM) Classifier
    Samir D. Mehta
    Ronnie Sebro
    Journal of Digital Imaging, 2020, 33 : 204 - 210
  • [40] Structural study of annealed BaMgAl10O17:Eu2+ using X-ray powder diffraction data
    Kim, YI
    Moon, SC
    Kang, SO
    Jung, MJ
    Hong, JS
    JOURNAL OF MATERIALS SCIENCE LETTERS, 2003, 22 (09) : 669 - 673