Developing a dual energy x-ray absorptiometry (DEXA) system using SrI2:Eu2+ coupled to silicon photomultiplier (SiPM)

被引:0
|
作者
Matei, Liviu [1 ]
Groza, Michael [2 ]
Gomez, Michelle [1 ]
Espinoza, Kricia Ruano [1 ]
Buliga, Vladimir [1 ]
Burger, Arnold [1 ]
机构
[1] Fisk Univ, Dept Phys, 1000 17th Ave North, Nashville, TN 37208 USA
[2] 2716 E Castleberg Loop, Nampa, ID 83686 USA
基金
美国国家科学基金会;
关键词
Bone Mineral Density; SrI2:Eu2+; Silicon Photomultiplier; Osteoporosis;
D O I
10.1117/12.2567674
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the evaluation of an alternative solution for detectors of dual energy x-ray absorptiometry systems. Bone mineral density (BMD) evaluation tools are crucial to the proper diagnosis of osteoporosis. The commercially available DEXA systems utilize CZT as the detector of the small dose of ionizing radiation passing through the area of interest. Our paper presents a novel Strontium Iodide doped with Europium (SrI2:Eu2+) scintillator crystal coupled to a Silicon Photomultiplier (SiPM) array as a less expensive alternative to CZT detector. Dual energy (60 keV and 122 keV) exposure was used for BMD measurements of a bone phantoms containing CaHPO4 to mimic bone and resin to mimic soft tissue. Calibration curves was determined for both BMD and for thickness measurements, validated by "unknown" phantoms. Both calibration curves lead to decreased errors compared to commercially available systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] DUAL ENERGY X-RAY ABSORPTIOMETRY (DEXA) FOR FRACTURE RISK ASSESSMENT IN HEPATITIS C VIRUS (HCV)-RELATED COMPENSATED ADVANCED CHRONIC LIVER DISEASE (CACLD) USING FRAX TOOL.
    Charak, Swati
    HEPATOLOGY, 2022, 76 : S393 - S394
  • [42] Computer-Aided Detection of Incidental Lumbar Spine Fractures from Routine Dual-Energy X-Ray Absorptiometry (DEXA) Studies Using a Support Vector Machine (SVM) Classifier
    Mehta, Samir D.
    Sebro, Ronnie
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 204 - 210
  • [43] LEAN BODY-MASS (LBM) MEASUREMENT IN CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS (CAPD) PATIENTS USING CREATININE KINETICS, BIOIMPEDANCE AND DUAL-ENERGY X-RAY ABSORPTIOMETRY (DEXA)
    BHATLA, B
    MOORE, HJ
    PROWANT, BF
    NOLPH, KD
    SINGH, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 488 - 488
  • [44] The assessment of skeletal status in young patients with Turner syndrome by 2 densitometric techniques: Phalangeal quantitative ultrasound and dual energy X-ray absorptiometry
    Wikiera, Beata
    Mierzwicka, Agata
    Basiak, Aleksander
    Halupczok-Zyla, Jowita
    Jedrzejuk, Diana
    Cabala, Magdalena
    Noczynska, Anna
    Bolanowski, Marek
    Mikolajczyk, Kornel
    Halaba, Zenon P.
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (06): : 759 - 764
  • [45] Validation of a Body Condition Scoring System in Rhesus Macaques (Macaca mulatta): Assessment of Body Composition by using Dual-Energy X-ray Absorptiometry
    Summers, Laura
    Clingerman, Karen J.
    Yang, Xiaowei
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2012, 51 (01): : 88 - 93
  • [46] Assessment of Bone Health Using Dual-Energy X-Ray Absorptiometry (DEXA) And Its Association with Dietary Intakes, Serum Vitamin D Levels, and Anthropometric Measures in Healthy Urban Preschool Children
    Sumithra Selvam
    Srinivasan K.
    Indian Journal of Pediatrics, 2023, 90 : 1191 - 1197
  • [47] ADRB2 gene variants, dual-energy x-ray absorptiometry body composition, and hypertension in Tobago men of African descent
    Beason, Tracey Samantha
    Bunker, Clareann H.
    Zmuda, Joseph M.
    Wilson, John W.
    Patrick, Alan L.
    Wheeler, Victor W.
    Weissfeld, Joel L.
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2011, 60 (05): : 698 - 705
  • [48] The Association between Body Composition using Dual energy X-ray Absorptiometry and Type-2 Diabetes: A Systematic Review and Meta-Analysis of Observational studies
    Gupta, Preeti
    Lanca, Carla
    Gan, Alfred T. L.
    Soh, Pauline
    Thakur, Sahil
    Tao, Yijin
    Kumari, Neelam
    Man, Ryan E. K.
    Fenwick, Eva K.
    Lamoureux, Ecosse L.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [49] Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry 43 hips followed for 2 years in a prospective trial
    Lindalen, Einar
    Dahl, Jon
    Nordsletten, Lars
    Snorrason, Finnur
    Hovik, Oystein
    Rohrl, Stephan
    ACTA ORTHOPAEDICA, 2012, 83 (06) : 592 - 598
  • [50] The Association between Body Composition using Dual energy X-ray Absorptiometry and Type-2 Diabetes: A Systematic Review and Meta-Analysis of Observational studies
    Preeti Gupta
    Carla Lanca
    Alfred T. L. Gan
    Pauline Soh
    Sahil Thakur
    Yijin Tao
    Neelam Kumari
    Ryan E. K. Man
    Eva K. Fenwick
    Ecosse L. Lamoureux
    Scientific Reports, 9