Estimation of CO2 storage capacity in porous media by using X-ray micro-CT

被引:14
|
作者
Liu, Yu [1 ]
Wang, Heming [1 ]
Shen, Zijian [1 ]
Song, Yongchen [1 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian, Peoples R China
来源
GHGT-11 | 2013年 / 37卷
关键词
CO2; storage; Capacity; X-ray CT; Saturation; Pore network; SEQUESTRATION; SELECTION;
D O I
10.1016/j.egypro.2013.06.436
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
CO2 storage in deep geological structures is considered to be a promising method for the mitigation of CO2 emission. Estimation of the capacity of a geological reservoir is of great importance. Core level study of CO2 storage mechanism and estimation of CO2 storage capacity at laboratory scale have shown to be great helpful for CO2 geological storage studies. This paper is proposed against the background of long term and safe storage of CO2 in deep saline aquifers. Experiments for CO2 storage in glass beads bed were inducted at laboratory scale. Quartz beads were filled and packed tightly in the imaging vessel. Gaseous CO2 was then injected into the sample at a constant flow rate and saturated water was driven out. Two CO2 injection directions in the vessel were chose, namely upwards and downwards to observe the effect of buoyancy. Three dimensional scans were carried out using a micro focus X-ray CT system to investigate the distribution of CO2 in sandstone cores. Digital cores of those samples were obtained after a series of imaging processing of media filtering, rescaling, and thresholding. Then a maximal ball (MB) algorithm was used to extract the equivalent pore networks. The parameters of the pore networks, such as coordination number, size distributions and shape factors of pore and throat were computed. Gas channeling phenomena was obviously found in water saturated beads bed while CO2 was injected upwards during displacement experiments. A short breakthrough time resulted in low sweep coefficient and only about 10% of saturated water was displaced. Nevertheless, about 80% of saturated water could be driven out and displaced by CO2 while it was injected downwards. Storage capacity of residual trapping was enhanced while CO2 was injected downwards along the beads bed. X-ray micro CT was proved to be an effective technique for the investigation of CO2 storage in core sample and a novel method for the estimation of CO2 storage capacity. (c) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:5201 / 5208
页数:8
相关论文
共 50 条
  • [31] The Application of X-ray Micro-CT in the Study of HTS Tape Coils
    Minasyan, Vitaly B.
    Ivanov, Nikolay S.
    Malykh, Elizaveta A.
    Zanegin, Yuri A.
    Douine, Bruno
    INVENTIONS, 2022, 7 (03)
  • [32] Machining accuracy detection of PCB hole by X-ray micro-CT
    Tao, Wenbin
    Xu, Ying
    Liu, Hao
    Wang, Chengyong
    Zheng, Lijuan
    MICRON, 2020, 131
  • [33] A realistic projection simulator for laboratory based X-ray micro-CT
    Dhaene, Jelle
    Pauwels, Elin
    De Schryver, Thomas
    De Muynck, Amelie
    Dierick, Manuel
    Van Hoorebeke, Luc
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 170 - 178
  • [34] Synchrotron Radiation X-Ray micro-CT evaluation of Bone Augmentation
    Rusu, Laura Cristina
    Seche, Eliza
    Freimann, Paul Cornel
    Hoinoiu, Bogdan
    Negrutiu, Meda Lavinia
    Ardelean, Lavinia
    Sinescu, Cosmin
    REVISTA DE CHIMIE, 2014, 65 (09): : 1114 - 1116
  • [35] Improvements in micro-CT method for characterizing X-ray monocapillary optics
    Wang, Zhao
    Pan, Kai
    Du, Zelin
    Zhang, Shuang
    Liu, Zhiguo
    OPTICS COMMUNICATIONS, 2022, 504
  • [36] MICROSTRUCTURE CHARACTERIZATION BY MEANS OF X-RAY MICRO-CT AND NANOINDENTATION MEASUREMENTS
    Rajczakowska, Magdalena
    Stefaniuk, Damian
    Lydzba, Dariusz
    STUDIA GEOTECHNICA ET MECHANICA, 2015, 37 (01) : 75 - 84
  • [37] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Elkhoury, Jean E.
    Shankar, Raji
    Ramakrishnan, T. S.
    TRANSPORT IN POROUS MEDIA, 2019, 129 (01) : 413 - 425
  • [38] Characterization and analysis of alumina clusters in steel by X-ray Micro-CT
    Zhao, Yi
    Ju, Liying
    Guo, Xiaopei
    Li, Tao
    Tan, Min
    Guo, Han
    Gu, Shaopeng
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 24 : 3252 - 3264
  • [39] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Jean E. Elkhoury
    Raji Shankar
    T. S. Ramakrishnan
    Transport in Porous Media, 2019, 129 : 413 - 425
  • [40] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226