Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones

被引:0
|
作者
Jean E. Elkhoury
Raji Shankar
T. S. Ramakrishnan
机构
[1] Schlumberger-Doll Research,
[2] Charles Stark Draper Laboratory,undefined
来源
Transport in Porous Media | 2019年 / 129卷
关键词
X-ray imaging; X-ray micro-computed tomography (; ); Resolution; Digital rock; Pixel size; Rock porosity; Sandstone; Limestone;
D O I
暂无
中图分类号
学科分类号
摘要
X-ray microtomography (μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document}) scanning provides high-resolution images in applications ranging from medical to material sciences and failure analysis. In general, CT scanning relies on X-ray absorption to produce a 3D computed image of the material. In Earth Sciences, μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} scans are used to characterize porosity and pore size, shape and topology of rock samples. For sufficiently large pore systems, the resulting segmented images may be used for quantitative transport calculations. In this note, we infer the limitations of μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} images of rock samples, caused by attainable resolution for a representative sample size. To this end, (1) we perform a systematic analysis with the aid of a resolution chart, (2) we present example scans of an Indiana limestone and a Berea sandstone mini-cores, and (3) we process and analyze the images to extract pore structures using different segmentation algorithms. Porosity estimates inferred from μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} images tend to be lower than bulk measurements.
引用
收藏
页码:413 / 425
页数:12
相关论文
共 50 条
  • [1] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Elkhoury, Jean E.
    Shankar, Raji
    Ramakrishnan, T. S.
    TRANSPORT IN POROUS MEDIA, 2019, 129 (01) : 413 - 425
  • [2] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340
  • [3] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [4] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [5] Optimal X-ray micro-CT image based methods for porosity and permeability quantification in heterogeneous sandstones
    Callow, Ben
    Falcon-Suarez, Ismael
    Marin-Moreno, Hector
    Bull, Jonathan M.
    Ahmed, Sharif
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2020, 223 (02) : 1210 - 1229
  • [6] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [7] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [8] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [9] Effectiveness of X-ray micro-CT applications upon mafic and ultramafic ophiolitic rocks
    Giamas, Vasileios
    Koutsovitis, Petros
    Sideridis, Alkiviadis
    Turberg, Pascal
    Grammatikopoulos, Tassos A.
    Petrounias, Petros
    Giannakopoulou, Panagiota P.
    Koukouzas, Nikolaos
    Hatzipanagiotou, Konstantin
    MICRON, 2022, 158
  • [10] Micro-CT of small insects by projection X-ray microscopy
    Tanisako, Akira
    Tsuruta, Susumu
    Hori, Ayumi
    Okumura, Aya
    Miyata, Chikara
    Kuzuryu, Chiaki
    Obi, Takashi
    Yoshimura, Hideyuki
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318