Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones

被引:0
|
作者
Jean E. Elkhoury
Raji Shankar
T. S. Ramakrishnan
机构
[1] Schlumberger-Doll Research,
[2] Charles Stark Draper Laboratory,undefined
来源
Transport in Porous Media | 2019年 / 129卷
关键词
X-ray imaging; X-ray micro-computed tomography (; ); Resolution; Digital rock; Pixel size; Rock porosity; Sandstone; Limestone;
D O I
暂无
中图分类号
学科分类号
摘要
X-ray microtomography (μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document}) scanning provides high-resolution images in applications ranging from medical to material sciences and failure analysis. In general, CT scanning relies on X-ray absorption to produce a 3D computed image of the material. In Earth Sciences, μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} scans are used to characterize porosity and pore size, shape and topology of rock samples. For sufficiently large pore systems, the resulting segmented images may be used for quantitative transport calculations. In this note, we infer the limitations of μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} images of rock samples, caused by attainable resolution for a representative sample size. To this end, (1) we perform a systematic analysis with the aid of a resolution chart, (2) we present example scans of an Indiana limestone and a Berea sandstone mini-cores, and (3) we process and analyze the images to extract pore structures using different segmentation algorithms. Porosity estimates inferred from μCT\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu \hbox {CT}$$\end{document} images tend to be lower than bulk measurements.
引用
收藏
页码:413 / 425
页数:12
相关论文
共 50 条
  • [31] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [32] X-ray micro-CT measurement of large parts at very low temperature
    Koutecky, T.
    Zikmund, T.
    Glittova, D.
    Palousek, D.
    Zivcak, J.
    Kaiser, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [33] X-ray Micro-CT based characterization of rock cuttings with deep learning
    Olsen, Nils
    Chen, Yifeng
    Turberg, Pascal
    Moreau, Alexandre
    Alahi, Alexandre
    APPLIED COMPUTING AND GEOSCIENCES, 2025, 25
  • [34] X-ray micro-CT applied to natural building materials and art objects
    De Witte, Y.
    Cnudde, V.
    Pieters, K.
    Masschaele, B.
    Dierick, M.
    Vlassenbroeck, J.
    Van Hoorebeke, L.
    Jacobs, P.
    X-RAY SPECTROMETRY, 2008, 37 (04) : 383 - 387
  • [35] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75
  • [36] Enhanced X-ray absorption for micro-CT analysis of low density polymers
    Crica, Livia Elena
    Wengenroth, Jonas
    Tiainen, Hanna
    Ionita, Mariana
    Haugen, Havard Jostein
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2016, 27 (09) : 805 - 823
  • [37] Statistical reconstruction for X-ray micro-CT systems with noncontinuous detectors.
    Zbijewski, Wojciech
    Beekman, Freek J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2323 - 2326
  • [38] A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT
    Ghanavati, Sahar
    Yu, Lisa X.
    Lerch, Jason P.
    Sled, John G.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 221 : 70 - 77
  • [39] Automated Segmentation of Murine Lung Tumors in X-ray micro-CT Images
    Swee, Joshua K. Y.
    Sheridan, Clare
    de Bruin, Elza
    Downward, Julian
    Lassailly, Francois
    Pizarro, Luis
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [40] A Reconstruction of the Lophophore of Devonian Rhynchonellids (Brachiopoda) by Using X-Ray Micro-CT
    Pakhnevich, A. V.
    PALEONTOLOGICAL JOURNAL, 2017, 51 (02) : 143 - 154