Improvements in micro-CT method for characterizing X-ray monocapillary optics

被引:2
|
作者
Wang, Zhao [1 ,2 ,3 ]
Pan, Kai [2 ,3 ]
Du, Zelin [2 ,3 ]
Zhang, Shuang [2 ,3 ]
Liu, Zhiguo [2 ,3 ,4 ]
机构
[1] China Acad Engn Phys, Inst Appl Elect, Mianyang 621900, Sichuan, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[3] Beijing Normal Univ, Dept Phys, Appl Opt Beijing Area Major Lab, Beijing 100875, Peoples R China
[4] Beijing Radiat Ctr, Beijing 100875, Peoples R China
关键词
X-ray monocapillary optics; Micro-CT; Sparse sampling; GPU acceleration; Geometric calibration; CONE-BEAM CT; GEOMETRIC CALIBRATION; IMAGE-RECONSTRUCTION; INNER DIAMETER; CONDENSER;
D O I
10.1016/j.optcom.2021.127474
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate characterization of the inner surface of X-ray monocapillary optics (XMCO) is of great significance in X-ray optics research. Compared with other characterization methods, the micro computed tomography (micro-CT) method has its unique advantages but also has some disadvantages, such as a long scanning time, long image reconstruction time, and inconvenient scanning process. In this paper, sparse sampling was proposed to shorten the scanning time, GPU acceleration technology was used to improve the speed of image reconstruction, and a simple geometric calibration algorithm was proposed to avoid the calibration phantom and simplify the scanning process. These methodologies will popularize the use of the micro-CT method in XMCO characterization.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Performance of assembled X-ray optics consisted of a polycapillary X-ray optics and a monocapillary X-ray optics for micro X-ray fluorescence spectrometry
    Sun, Xuepeng
    Zhang, Xiaoyun
    Wang, Yabing
    Shao, Shangkun
    Li, Yufei
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 165
  • [2] Glass Monocapillary X-ray Optics And Their Applications In X-ray Microscopy
    Zeng, X.
    Feser, M.
    Huang, E.
    Lyon, A.
    Yun, W.
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 41 - 47
  • [3] Characterizing the inner surface of parabolic monocapillary with contrast-enhanced micro-CT technology and ray-tracing computing method
    Zhang, Shuang
    Pan, Kai
    Zhou, Peng
    Liu, Zhiguo
    Li, Yude
    Sun, Tianxi
    OPTICS COMMUNICATIONS, 2020, 475
  • [4] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [5] Tapered monocapillary optics for synchrotron x-ray microfocusing
    Balaic, DX
    Barnea, Z
    Varghese, JN
    Cholewa, M
    Dillon, CT
    Lay, PA
    Shea-McCarthy, G
    X-RAY MICROFOCUSING: APPLICATIONS AND TECHNIQUES, 1998, 3449 : 157 - 164
  • [6] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [7] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [8] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [9] Characterizing gas bubble size distribution of laboratory foamed cement using X-ray micro-CT
    Pang, Xueyu
    Singh, John
    Jimenez, Walmy Cuello
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 167 : 243 - 252
  • [10] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340