Improvements in micro-CT method for characterizing X-ray monocapillary optics

被引:2
|
作者
Wang, Zhao [1 ,2 ,3 ]
Pan, Kai [2 ,3 ]
Du, Zelin [2 ,3 ]
Zhang, Shuang [2 ,3 ]
Liu, Zhiguo [2 ,3 ,4 ]
机构
[1] China Acad Engn Phys, Inst Appl Elect, Mianyang 621900, Sichuan, Peoples R China
[2] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
[3] Beijing Normal Univ, Dept Phys, Appl Opt Beijing Area Major Lab, Beijing 100875, Peoples R China
[4] Beijing Radiat Ctr, Beijing 100875, Peoples R China
关键词
X-ray monocapillary optics; Micro-CT; Sparse sampling; GPU acceleration; Geometric calibration; CONE-BEAM CT; GEOMETRIC CALIBRATION; IMAGE-RECONSTRUCTION; INNER DIAMETER; CONDENSER;
D O I
10.1016/j.optcom.2021.127474
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate characterization of the inner surface of X-ray monocapillary optics (XMCO) is of great significance in X-ray optics research. Compared with other characterization methods, the micro computed tomography (micro-CT) method has its unique advantages but also has some disadvantages, such as a long scanning time, long image reconstruction time, and inconvenient scanning process. In this paper, sparse sampling was proposed to shorten the scanning time, GPU acceleration technology was used to improve the speed of image reconstruction, and a simple geometric calibration algorithm was proposed to avoid the calibration phantom and simplify the scanning process. These methodologies will popularize the use of the micro-CT method in XMCO characterization.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Automated Segmentation of Murine Lung Tumors in X-ray micro-CT Images
    Swee, Joshua K. Y.
    Sheridan, Clare
    de Bruin, Elza
    Downward, Julian
    Lassailly, Francois
    Pizarro, Luis
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [42] A Reconstruction of the Lophophore of Devonian Rhynchonellids (Brachiopoda) by Using X-Ray Micro-CT
    Pakhnevich, A. V.
    PALEONTOLOGICAL JOURNAL, 2017, 51 (02) : 143 - 154
  • [43] Optimizing monocapillary optics for synchrotron x-ray diffraction, fluorescence imaging, and spectroscopy applications
    Bilderback, Donald H.
    Kazimirov, Alexander
    Gillilan, Richard
    Cornaby, Sterling
    Woll, Arthur
    Zha, Chang-Sheng
    Huang, Rong
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 758 - +
  • [44] APPLICATION OF X-RAY MICRO-CT METHOD TO ASSESS DAMAGE/FLAW PRESENCE AND PROGRESSION IN TIRE RUBBER MATERIALS
    Liu, Ruofan
    Sancaktar, Erol
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 3, 2016,
  • [45] Simulation of optical properties of ellipsoidal monocapillary X-ray optics with inner-surface imperfections
    Zhang, Shuang
    Pan, Kai
    Wang, Zhao
    Zhou, Peng
    Liu, Zhiguo
    Sun, Xuepeng
    Li, Yude
    Sun, Tianxi
    OPTICS COMMUNICATIONS, 2021, 493
  • [46] Development of two-dimensional beam hardening correction for X-ray micro-CT
    Davis, Graham R.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 863 - 874
  • [47] Time-optimized X-ray micro-CT imaging of polymer based scaffolds
    Morris, David E.
    Mather, Melissa L.
    Simon, Carl G., Jr.
    Crowe, John A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) : 360 - 367
  • [48] Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms
    Alona Keren-Paz
    Vlad Brumfeld
    Yaara Oppenheimer-Shaanan
    Ilana Kolodkin-Gal
    npj Biofilms and Microbiomes, 4
  • [49] X-ray Micro-CT and DVC Based Analysis of Strains in Metallization of Flexible Electronics
    Lall, Pradeep
    Wei, Junchao
    PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 1253 - 1261
  • [50] Sodium Iodide as a Contrast Agent for X-ray Micro-CT of a Wood Plastic Composite
    Feng, Dengcheng
    Turner, Michael
    Evans, Philip D.
    APPLIED SCIENCES-BASEL, 2022, 12 (01):