Characterizing gas bubble size distribution of laboratory foamed cement using X-ray micro-CT

被引:23
|
作者
Pang, Xueyu [1 ]
Singh, John [1 ]
Jimenez, Walmy Cuello [1 ]
机构
[1] Halliburton, 3000 N Sam Houston Pkwy E, Houston, TX 77032 USA
关键词
Foamed cement; Micro-computed tomography; Bubble size distribution; Shear rate; Mixing energy; Foam quality; Applied pressure; Normal distribution; SLURRIES;
D O I
10.1016/j.conbuildmat.2018.02.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objectives of this study are to use micro-computed tomography (micro-CT) to elucidate the influencing factors of the microstructure of laboratory foamed cement and develop statistical models to quantify the gas bubble size distributions. During this study, foamed cement slurries were prepared using sealed foam cement mixers at various operating conditions. The influences of shear rate, mixing energy, base cement slurry composition, blender geometry, and applied pressure on the gas bubble size distribution of set foamed cement were investigated. Test results indicate foam quality and gas pressure are the primary determining factors of gas bubble size in foamed cement. The gas bubble size in foamed cement produced by a sealed foam mixer approximately follows the normal distribution. For samples generated with a standard multiblade blender at atmospheric condition, the mean and standard deviation of gas bubble size distribution increase exponentially with increasing foam quality. A dramatic decrease in gas bubble size is observed with increasing gas pressure. On the other hand, variations in mixing energy, shear rate, base slurry composition, and blender geometry have relatively little effect on the microstructure of the foamed cement within the range investigated. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:243 / 252
页数:10
相关论文
共 50 条
  • [1] Improvements in micro-CT method for characterizing X-ray monocapillary optics
    Wang, Zhao
    Pan, Kai
    Du, Zelin
    Zhang, Shuang
    Liu, Zhiguo
    OPTICS COMMUNICATIONS, 2022, 504
  • [2] A realistic projection simulator for laboratory based X-ray micro-CT
    Dhaene, Jelle
    Pauwels, Elin
    De Schryver, Thomas
    De Muynck, Amelie
    Dierick, Manuel
    Van Hoorebeke, Luc
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 170 - 178
  • [3] Imaging of metallic foams using X-ray micro-CT
    Saadatfar, M.
    Garcia-Moreno, F.
    Hutzler, S.
    Sheppard, A. P.
    Knackstedt, M. A.
    Banhart, J.
    Weaire, D.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 344 (1-3) : 107 - 112
  • [4] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [5] Virtual characterisation of porcupine quills using X-ray micro-CT
    Tee, Yun Lu
    Black, Jay R.
    Phuong Tran
    VIRTUAL AND PHYSICAL PROTOTYPING, 2023, 18 (01)
  • [6] Multiscale characterization of glass wools using X-ray micro-CT
    Meftah, Redouane
    Berger, Sylvain
    Jacqus, Gary
    Laluet, Jean-Yves
    Cnudde, Veerle
    MATERIALS CHARACTERIZATION, 2019, 156
  • [7] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [8] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [9] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [10] A reconstruction of the lophophore of Devonian rhynchonellids (Brachiopoda) by using X-Ray micro-CT
    A. V. Pakhnevich
    Paleontological Journal, 2017, 51 : 143 - 154