Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators

被引:20
|
作者
Serfozo, Norbert [1 ]
Ondracek, Jakub [2 ]
Zikova, Nadezda [2 ]
Lazaridis, Mihalis [1 ]
Zdimal, Vladimir [2 ]
机构
[1] Tech Univ Crete, Sch Environm Engn, Polytechneioupolis, Khania 73100, Greece
[2] Acad Sci Czech Republ, Inst Chem Proc Fundamentals, Vvi, Rozvojova 135, CR-16502 Prague, Czech Republic
关键词
Size-resolved penetration; CE-marked respirator; Monodisperse ammonium sulfate; 47 mm filter sample; EN; 149; AEROSOL TESTING PARAMETERS; HEALTH-CARE WORKERS; FILTRATION PERFORMANCE; COLLECTION EFFICIENCY; CARBON NANOTUBES; PARTICLE-SIZE; N95; DUST; MASKS; PROTECTION;
D O I
10.4209/aaqr.2016.09.0390
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Throughout the years, the performance of the FFRs has been the topic of extensive studies, resulting mainly in the characterization of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces. There are limited number of studies in the literature reporting CE-marked respirator performance, and there is a need to perform a penetration evaluation of CE-marked respirators through all 3 filtering classes: FFP1 (80%), FFP2 (94%), and FFP3 (99%). In this study, the percentage penetrations and the most penetrating particle size (MPPS) of 47 mm filters cut out from 13 different CE-marked respirator half masks (2 samples of each FFR) were evaluated size-selectively using nine sizes of charge-neutralized monodisperse aerosol, which ranged from 20 to 400 nm (CMD). Comparison of the penetrations at MPPS from all the examined filters showed that the percentage penetration ranged 3.2-16.3% (FFP1), 2.4-34.3% (FFP2), and 0.02-3.3% (FFP3). Experimental data also revealed that the penetration difference between 2 samples from the same respirator was in most cases up to 6.8%, and between 2 identical respirators up to 2.5%. The MPPS was found to be between 30 and 60 nm (CMD) in all measurements. By comparing the obtained results to the European Standard we conclude that the standard method underestimates particle penetration (especially for particles < 100 nm) due to the usage of non-neutralized, polydisperse test aerosol, detection methods burdened with measurement artifacts, and the assumption that the MPPS is at approximate to 600 nm (MMD) as the criterion for filtering facepieces to pass the penetration test.
引用
收藏
页码:1305 / 1315
页数:11
相关论文
共 21 条
  • [1] Manikin-based size-resolved penetrations of CE-marked filtering facepiece respirators
    Serfozo, Norbert
    Ondracek, Jakub
    Otahal, Petr
    Lazaridis, Mihalis
    Zdimal, Vladimir
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (12) : 965 - 974
  • [2] Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators
    Rengasamy, Samy
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2009, 53 (02): : 117 - 128
  • [3] FIBER RELEASE FROM FILTERING FACEPIECE RESPIRATORS
    HOWIE, RM
    ADDISON, J
    CHERRIE, J
    ROBERTSON, A
    DODGSON, J
    ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (01): : 131 - 133
  • [4] Inference and sample size calculation in the fit assessment of filtering facepiece respirators
    Zhang, Zhiwei
    Kotz, Richard M.
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2008, 18 (04) : 713 - 723
  • [5] Generalized Kubelka's theory for light transmission in multilayer materials and its application for UV light penetration in filtering facepiece respirators
    Farnood, Ramin
    Mahmoud, Housyn
    Gibson, John
    Mao, Ted
    Odegaard, Conrad
    JOURNAL OF BIOPHOTONICS, 2022, 15 (10)
  • [6] Penetration of Combustion Aerosol Particles Through Filters of NIOSH-Certified Filtering Facepiece Respirators (FFRs)
    Gao, Shuang
    Kim, Jinyong
    Yermakov, Michael
    Elmashae, Yousef
    He, Xinjian
    Reponen, Tiina
    Grinshpun, Sergey A.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2015, 12 (10) : 678 - 685
  • [7] Development of a new test system to determine penetration of multi-walled carbon nanotubes through filtering facepiece respirators
    Vo, Evanly
    Zhuang, Ziqing
    JOURNAL OF AEROSOL SCIENCE, 2013, 61 : 50 - 59
  • [8] Nanoparticle Penetration through Filter Media and Leakage through Face Seal Interface of N95 Filtering Facepiece Respirators
    Rengasamy, Samy
    Eimer, Benjamin C.
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (05): : 568 - 580
  • [9] Laboratory Faceseal Leakage Evaluation of N95 Filtering Facepiece Respirators Against Nanoparticles and "All Size" Particles
    Zhuang, Ziqing
    Bergman, Michael S.
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2013, 10 (09) : 496 - 504
  • [10] Resistance to synthetic blood penetration of National Institute for Occupational Safety and Health-approved N95 filtering facepiece respirators and surgical N95 respirators
    Rengasamy, Samy
    Sbarra, Deborah
    Nwoko, Julian
    Shaffer, Ronald
    AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (11) : 1190 - 1196