Manikin-based size-resolved penetrations of CE-marked filtering facepiece respirators

被引:8
|
作者
Serfozo, Norbert [1 ]
Ondracek, Jakub [2 ]
Otahal, Petr [3 ]
Lazaridis, Mihalis [1 ]
Zdimal, Vladimir [2 ]
机构
[1] Tech Univ Crete, Polytechneioupolis, Sch Environm Engn, Khania 73132, Greece
[2] Acad Sci Czech Republ, Inst Chem Proc Fundamentals, Prague, Czech Republic
[3] Natl Inst Nucl Chem & Biol Protect, Milin, Czech Republic
关键词
CE-marked respirator; EN; 149; manikin-based study; monodisperse ammonium sulfate; size-resolved penetration; PERFORMANCE EVALUATION; EXHALATION VALVES; N95; RESPIRATORS; PARTICLES; MEDIA; NANOPARTICLES; AEROSOLS; LEAKAGE; MASKS;
D O I
10.1080/15459624.2017.1358816
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this manikin-based study was to determine the percentage penetrations of nine CE-marked filtering facepiece respirator models (two samples from each) from filtering classes FFP1, FFP2, and FFP3 and to demonstrate by an independent measurement method the disadvantages and shortcomings of the currently valid European Norm (EN 149: 2001) for filtering facepieces. All of the filtering facepieces were evaluated size-selectively in an experimental chamber using charge-neutralized monodisperse ammonium sulfate in 9 sizes ranging from 20-400 nm of count median diameter (CMD) under flowrate of 95 L/min. The results were then compared to the previous study concerning penetrations of 47-mm diameter filters cut from the filtering material of identical filtering facepieces. Although these two experimental methods for measuring penetrations of filtering materials from filtering facepieces are in good agreement (R-2 = 0.91), the results show within-respirator variations in all three filtering classes (5.5-19.3% for all FFRs in FFP1, 2.8-8.5% in FFP2, and 0.1-2.8% in FFP3). The most penetrating particle size (MPPS) in this study was found to be in the range of 25-65 nm (CMD), which is in agreement with the range of 30-60 nm found in the previous study. Moreover, 7 out of 9 FFR models reached higher penetrations from manikin-based respirator measurements than during measurements of filters from the respective respirators. Furthermore, penetration levels increased up to similar to 50% when the respirator was not sealed around the face of the manikin, indicating that the real protection level provided by these filtering facepieces may be even lower if the respirator does not fit perfectly. Considering that poor filtration efficiency and poor fit may increase under real work conditions, the particle penetration is even higher than was found in this study. Therefore, the CE-marked respirators examined in this study may not be efficient in providing the expected level of protection for workers exposed to nanoparticles.
引用
收藏
页码:965 / 974
页数:10
相关论文
共 3 条
  • [1] Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators
    Serfozo, Norbert
    Ondracek, Jakub
    Zikova, Nadezda
    Lazaridis, Mihalis
    Zdimal, Vladimir
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (05) : 1305 - 1315
  • [2] Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators
    Rengasamy, Samy
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2009, 53 (02): : 117 - 128
  • [3] Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles
    Balazy, A
    Toivola, M
    Reponen, T
    Podgo,rski, A
    Zimmer, A
    Grinshpun, SA
    ANNALS OF OCCUPATIONAL HYGIENE, 2006, 50 (03): : 259 - 269