Inference and sample size calculation in the fit assessment of filtering facepiece respirators

被引:3
|
作者
Zhang, Zhiwei [1 ]
Kotz, Richard M. [1 ]
机构
[1] US FDA, Div Biostat, OSB, Ctr Devices & Radiol Hlth, Rockville, MD 20850 USA
关键词
analysis of variance; delta method; random effect; respirator; sample size; variance component;
D O I
10.1080/10543400802071394
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Filtering facepiece respirators have recently been cleared by the U.S. Food and Drug Administration (FDA) for use by the general public in public health medical emergencies such as pandemic influenza. In the fit assessment of these devices it is important to distinguish between the two sources of variability: population heterogeneity and random fluctuations over repeated donnings. The FDA Special Controls Guidance Document (SCGD) which describes these devices and their evaluation, recommends that the fit performance of a filtering facepiece respirator be evaluated in terms of the proportion of users who will receive a specified level of protection 95% of the time. A point estimator of this proportion is easily obtained under an analysis of variance model, and the SCGD suggests bootstrap as one possible approach to interval estimation. This paper describes a closed-form procedure to obtain confidence intervals and provides sample size formulas. Simulation results suggest that the proposed procedure performs well in realistic settings and compares favorably to two simple bootstrap procedures.
引用
收藏
页码:713 / 723
页数:11
相关论文
共 50 条
  • [1] Improving the fit of filtering facepiece respirators
    Shah, Kamini
    Serban, Stefan
    Douglas, Gail V. A.
    BRITISH DENTAL JOURNAL, 2022,
  • [2] Understanding Filtering Facepiece Respirators
    Andrews, Angela S.
    Kiederer, Meghan
    Casey, Megan L.
    AMERICAN JOURNAL OF NURSING, 2022, 122 (02) : 21 - 23
  • [3] Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators
    Janssen, L
    Luinenburg, MD
    Mullins, HE
    Danisch, SG
    Nelson, TJ
    AIHA JOURNAL, 2003, 64 (04): : 480 - 486
  • [4] Evaluation of Sampling Probes for Fit Testing N95 Filtering Facepiece Respirators
    Bergman, Michael S.
    Viscusi, Dennis J.
    Zhuang, Ziqing
    Newcomb, William E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2013, 57 (04): : 507 - 518
  • [5] FIBER RELEASE FROM FILTERING FACEPIECE RESPIRATORS
    HOWIE, RM
    ADDISON, J
    CHERRIE, J
    ROBERTSON, A
    DODGSON, J
    ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (01): : 131 - 133
  • [6] Face anthropometry for filtering facepiece respirators: analysis of the association between facial dimensions and respirator fit
    Yu, Minji
    Griffin, Linsey
    Durfee, William K.
    Arnold, Susan
    ANNALS OF WORK EXPOSURES AND HEALTH, 2024, 68 (03) : 312 - 324
  • [7] Decontamination Methods for Reuse of Filtering Facepiece Respirators
    Su-Velez, Brooke M.
    Maxim, Tom
    Long, Jennifer L.
    St John, Maie A.
    Holliday, Michael A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (08) : 734 - 740
  • [8] The Effect on Fit of Multiple Consecutive Donning and Doffing of N95 Filtering Facepiece Respirators
    Vuma, Cynthia Danisile
    Manganyi, Jeanneth
    Wilson, Kerry
    Rees, David
    ANNALS OF WORK EXPOSURES AND HEALTH, 2019, 63 (08) : 930 - 936
  • [9] Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators
    Serfozo, Norbert
    Ondracek, Jakub
    Zikova, Nadezda
    Lazaridis, Mihalis
    Zdimal, Vladimir
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (05) : 1305 - 1315
  • [10] Limited Reuse and Extended Use of Filtering Facepiece Respirators
    Company Sancho, Maria Consuelo
    Gonzalez-Maria, Esther
    Abad-Corpa, Eva
    ENFERMERIA CLINICA, 2021, 31 : S78 - S83