Size-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators

被引:20
|
作者
Serfozo, Norbert [1 ]
Ondracek, Jakub [2 ]
Zikova, Nadezda [2 ]
Lazaridis, Mihalis [1 ]
Zdimal, Vladimir [2 ]
机构
[1] Tech Univ Crete, Sch Environm Engn, Polytechneioupolis, Khania 73100, Greece
[2] Acad Sci Czech Republ, Inst Chem Proc Fundamentals, Vvi, Rozvojova 135, CR-16502 Prague, Czech Republic
关键词
Size-resolved penetration; CE-marked respirator; Monodisperse ammonium sulfate; 47 mm filter sample; EN; 149; AEROSOL TESTING PARAMETERS; HEALTH-CARE WORKERS; FILTRATION PERFORMANCE; COLLECTION EFFICIENCY; CARBON NANOTUBES; PARTICLE-SIZE; N95; DUST; MASKS; PROTECTION;
D O I
10.4209/aaqr.2016.09.0390
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Throughout the years, the performance of the FFRs has been the topic of extensive studies, resulting mainly in the characterization of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces. There are limited number of studies in the literature reporting CE-marked respirator performance, and there is a need to perform a penetration evaluation of CE-marked respirators through all 3 filtering classes: FFP1 (80%), FFP2 (94%), and FFP3 (99%). In this study, the percentage penetrations and the most penetrating particle size (MPPS) of 47 mm filters cut out from 13 different CE-marked respirator half masks (2 samples of each FFR) were evaluated size-selectively using nine sizes of charge-neutralized monodisperse aerosol, which ranged from 20 to 400 nm (CMD). Comparison of the penetrations at MPPS from all the examined filters showed that the percentage penetration ranged 3.2-16.3% (FFP1), 2.4-34.3% (FFP2), and 0.02-3.3% (FFP3). Experimental data also revealed that the penetration difference between 2 samples from the same respirator was in most cases up to 6.8%, and between 2 identical respirators up to 2.5%. The MPPS was found to be between 30 and 60 nm (CMD) in all measurements. By comparing the obtained results to the European Standard we conclude that the standard method underestimates particle penetration (especially for particles < 100 nm) due to the usage of non-neutralized, polydisperse test aerosol, detection methods burdened with measurement artifacts, and the assumption that the MPPS is at approximate to 600 nm (MMD) as the criterion for filtering facepieces to pass the penetration test.
引用
收藏
页码:1305 / 1315
页数:11
相关论文
共 21 条
  • [11] Penetration of Fiber Versus Spherical Particles Through Filter Media and Faceseal Leakage of N95 Filtering Facepiece Respirators with Cyclic Flow
    Cho, Kyungmin Jacob
    Turkevich, Leonid
    Miller, Matthew
    McKay, Roy
    Grinshpun, Sergey A.
    Ha, KwonChul
    Reponen, Tiina
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2013, 10 (03) : 109 - 115
  • [12] A scoping review of surgical masks and N95 filtering facepiece respirators: Learning from the past to guide the future of dentistry
    Smith, P. Bradford
    Agostini, Gina
    Mitchell, John C.
    SAFETY SCIENCE, 2020, 131
  • [13] Implementing fit testing for N95 filtering facepiece respirators: Practical information from a large cohort of hospital workers
    McMahon, Elizabeth
    Wada, Koji
    Dufresne, Andre
    AMERICAN JOURNAL OF INFECTION CONTROL, 2008, 36 (04) : 298 - 300
  • [15] Effects of volume, velocity, and composition on the resistance to synthetic blood penetration of N95 filtering facepiece respirators and other head/facial personal protective equipment
    Portnoff, Lee
    Rengasamy, Samy
    Niezgoda, George
    Sbarra, Deborah
    Pissano, Anthony
    Furlong, Jennifer
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2021, 18 (02) : 84 - 89
  • [16] Transfer of bacteriophage MS2 and fluorescein from N95 filtering facepiece respirators to hands: Measuring fomite potential
    Brady, Tyler M.
    Strauch, Amanda L.
    Almaguer, Claudia M.
    Niezgoda, George
    Shaffer, Ronald E.
    Yorio, Patrick L.
    Fisher, Edward M.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (11) : 898 - 906
  • [17] A Quantitative Assessment of the Total Inward Leakage of NaCl Aerosol Representing Submicron-Size Bioaerosol Through N95 Filtering Facepiece Respirators and Surgical Masks
    Rengasamy, Samy
    Eimer, Benjamin C.
    Szalajda, Jonathan
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2014, 11 (06) : 388 - 396
  • [18] Filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators against 4 to 30 nanometer-size nanoparticles
    Rengasamy, Samy
    King, William P.
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (09) : 556 - 564
  • [19] Use of thin silicone dressings for prolonged use of filtering facepiece respirators: Lessons from the universal community testing programme during the COVID-19
    Yip, Ka-Huen
    Yip, Yuk-Chiu
    INTERNATIONAL WOUND JOURNAL, 2022, 19 (05) : 1188 - 1196
  • [20] Application of direct-reading and elemental carbon analysis methods to measure mass-based penetration of carbon nanotubes through elastomeric half-face and filtering facepiece respirators
    Vo, Evanly
    Zhuang, Ziqing
    Birch, Eileen
    Birch, Quinn
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (10) : 1044 - 1054