Experimental study on double pipe PCM floor heating system under different operation strategies

被引:70
|
作者
Lu, Shilei [1 ]
Xu, Bowen [1 ]
Tang, Xiaolei [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
基金
国家重点研发计划;
关键词
Phase change material; Double-pipe; Floor heating system; Operation strategy; PHASE-CHANGE MATERIALS; THERMAL-ENERGY STORAGE; SHAPE-STABILIZED PCM; OF-THE-ART; BUILDING WALLS; PERFORMANCE; LATENT; ENHANCEMENT; VENTILATION; SIMULATION;
D O I
10.1016/j.renene.2019.06.086
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Phase change material (PCM) can be integrated into floor heating system to store excess heat, releasing it when needed, thus effectively reducing the mismatch between energy supply and demand. In this study, a double pipe PCM floor heating system with three independent heating modules was proposed for clean energy heating in rural China. A 26-day experimental study was conducted to study the operation effect of the system under four different strategies. Strategy 1: partial power operation strategy; Strategy 2: daytime energy storage strategy; Strategy 3: nocturnal energy storage strategy; and Strategy 4: phased energy storage strategy. In the early stage of heating, the average temperature of experiment room was 18.9 degrees C and the daily temperature fluctuation was controlled within 2.1 degrees C, which showed an effective guarantee of indoor comfort under Strategy 1. In the late stage of heating, the differences in indoor temperature fluctuations could be caused by changes in outdoor climate and operation strategies. And operating strategy had less impact on indoor temperature distribution. Moreover, the experiment results revealed that the system could provide a comfortable indoor thermal environment while adjusting operational strategies. And the 3 C average daily temperature fluctuation confirmed the feasibility of creating a comfortable environment with gentle temperature fluctuations via the PCM floor intermittent heating. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1280 / 1291
页数:12
相关论文
共 50 条
  • [31] Experimental Investigation on a Novel Necking Heat Pipe with Double-End Heating for Thermal Management of the Overload Operation
    Li, Jie
    Zhang, Shiwei
    Tang, Heng
    Liang, Yifu
    Wang, Sheng
    Zhong, Guisheng
    Tang, Yong
    APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [32] Experimental Study on Running Spacing of Buried Pipe and System Heating Performance in GSHP System
    Hu, Songtao
    Lin, Bo
    Shi, Zhigang
    Yu, Hengjie
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 519 - 526
  • [33] An Experimental Study on Continuous and Intermittent Control for Radiant Floor Heating System with DSHP
    Wei, Xinli
    Wu, Jinjing
    Zeng, Zhangchuan
    Lu, Jifu
    Chen, WanRen
    Wei, ZongDi
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1545 - 1552
  • [34] Experimental and Numerical Study of Newly Assembled Lightweight Radiant Floor Heating System
    Zhang, Baogang
    Wang, Yongjuan
    Liu, Ming
    Zhang, Zhongbing
    BUILDINGS, 2024, 14 (07)
  • [35] Experimental Study of a Low-temperature Electrical Radiant Floor Heating System
    Kong, Xiangqiang
    Li, Ying
    Wang, Ruzhu
    Hu, Songtao
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1593 - 1600
  • [36] Experimental study of low-temperature electrical radiant floor heating system
    Kong, Xiangqiang
    Li, Ying
    Hu, Songtao
    Journal of Southeast University (English Edition), 2010, 26 (02) : 287 - 291
  • [37] An experimental and simulation study on performance of solar-powered floor heating system
    Song, Z. P.
    Wang, R. Z.
    Zhai, X. Q.
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 2224 - 2228
  • [38] Experimental Study for the Reinforcement of District Heating Pipe
    Kim, Jaemin
    Kim, Jooyong
    Cho, Chongdu
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2016, 40 (03) : 245 - 252
  • [39] Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes
    Dai, Lanhua
    Li, Sufen
    Lin DuanMu
    Li, Xiangli
    Shang, Yan
    Dong, Ming
    APPLIED THERMAL ENGINEERING, 2015, 75 : 325 - 333
  • [40] WIRSBO PEX UNDER FLOOR HEATING-SYSTEM
    ARAUCHI, M
    SUZUKI, T
    SUMITOMO LIGHT METAL TECHNICAL REPORTS, 1983, 24 (1-2): : 71 - 76