Noninvasive cardiac output monitoring (NICOM): a clinical validation

被引:235
|
作者
Squara, Pierre [1 ]
Denjean, Dominique [1 ]
Estagnasie, Philippe [1 ]
Brusset, Alain [1 ]
Dib, Jean Claude [1 ]
Dubois, Claude [1 ]
机构
[1] CERIC, Clin Ambroise Pare, F-92200 Neuilly Sur Seine, France
关键词
D O I
10.1007/s00134-007-0640-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the clinical utility of a new device for continuous noninvasive cardiac output monitoring (NICOM) based on chest bio-reactance compared with cardiac output measured semi-continuously by thermodilution using a pulmonary artery catheter (PAC-CCO). Design: Prospective, single-center study. Setting: Intensive care unit. Patients: Consecutive adult patients immediately after cardiac surgery. Interventions: Cardiac output measurements obtained from NICOM and thermodilution were simultaneously recorded minute by minute and compared in 110 patients. We evaluated the accuracy, precision, responsiveness, and reliability of NICOM for detecting cardiac output changes. Tolerance for each of these parameters was specified prospectively. Measurements and results: A total of 65,888 pairs of cardiac output measurements were collected. Mean reference values for cardiac output ranged from 2.79 to 9.271/min. During periods of stable PAC-CCO (slope < +/- 10%, 2SD/mean < 20%), the correlation between NICOM and thermodilution was R=0.82; bias was +0.16 +/- 0.521/min (+4.0 +/- 11.3%), and relative error was 9.1%+/- 7.8%. In 85% of patients the relative error was < 20%. During periods of increasing output, slopes were similar with the two methods in 96% of patients and intra-class correlation was positive in 96%. Corresponding values during periods of decreasing output were 90% and 84%, respectively. Precision was always better with NICOM than with thermodilution. During hemodynamic challenges, changes were 3.1 +/- 3.8min faster with NICOM (p < 0.01) and amplitude of changes did not differ significantly. Finally, sensitivity of the NICOM for detecting significant directional changes was 93% and specificity was 93%. Conclusion:Cardiac output measured by NICOM had most often acceptable accuracy, precision, and responsiveness in a wide range of circulatory situations.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 50 条
  • [1] Noninvasive cardiac output monitoring (NICOM): a clinical validation
    Pierre Squara
    Dominique Denjean
    Philippe Estagnasie
    Alain Brusset
    Jean Claude Dib
    Claude Dubois
    Intensive Care Medicine, 2007, 33 : 1191 - 1194
  • [2] Noninvasive cardiac output monitoring: a clinical validation
    P Squara
    P Estagnasie
    A Brusset
    D Denjean
    J Dib
    C Dubois
    Critical Care, 11 (Suppl 2):
  • [3] Validation of a noninvasive cardiac output monitor in maternal cardiac disease: comparison of NICOM and transthoracic echocardiogram
    Florio, Karen L.
    Williams, Emily M.
    White, Darcy
    Daming, Tara
    Hostetter, Sarah
    Schrufer-Poland, Tabitha
    Gray, Rebecca
    Schmidt, Laura
    Grodzinsky, Anna
    Lee, John
    Rader, Valerie
    Swearingen, Kathleen
    Nelson, Lynne
    Patel, Neil
    Magalski, Anthony
    Gosch, Kensey
    Jones, Philip
    Fu, Zhuxuan
    Spertus, John A.
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2024, 6 (03)
  • [4] Noninvasive Cardiac Output Monitoring in Critically Ill Adults: A Comparison of Bioreactance (NICOM™) with Transthoracic Echocardiography
    Abdulmahdi, M.
    Amaral, V.
    Skaanland, A.
    Garcia, P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [5] Noninvasive Cardiac Output Monitoring (NICOM) in the Critically Ill Patient Undergoing Endotracheal Intubation: A Prospective Observational Study
    Smischney, Nathan J.
    Stoltenberg, Anita D.
    Schroeder, Darrell R.
    DeAngelis, Jillian L.
    Kaufman, David A.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2023, 38 (12) : 1108 - 1120
  • [6] Noninvasive cardiac output monitoring
    Popovich, MJ
    Hoffman, WD
    CRITICAL CARE MEDICINE, 1997, 25 (11) : 1783 - 1784
  • [7] Noninvasive cardiac output monitoring
    Dueck, R
    CHEST, 2001, 120 (02) : 339 - 341
  • [8] Comparison of a noninvasive cardiac output monitor (NICOM) with simultaneous transthoracic echocardiography in pregnant women
    Florio, Karen
    Williams, Emily
    White, Darcy
    Daming, Tara Banaszek
    Hostetter, Sarah
    Schrufer-Poland, Tabitha L.
    Gray, Rebecca
    Schmidt, Laura
    Grodzinsky, Anna
    Lee, John
    Rader, Valerie
    Swearingen, Kathleen
    Nelson, Lynne
    Magalaski, Anthony
    Spertus, John
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S338 - S338
  • [9] Non-Invasive Cardiac Output Monitoring in Cardiogenic Shock: The NICOM Study
    Rali, Aniket S.
    Buechler, Tyler
    Van Gotten, Bridget
    Waters, Andrew
    Shah, Zubair
    Haglund, Nicholas
    Sauer, Andrew
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (02) : 160 - 165
  • [10] Cardiac output monitoring - invasive and noninvasive
    Arya, Virendra K.
    Al-Moustadi, Waiel
    Dutta, Vikas
    CURRENT OPINION IN CRITICAL CARE, 2022, 28 (03) : 340 - 347