3-D geometry calibration and markerless electromagnetic tracking with a mobile C-arm

被引:2
|
作者
Cheryauka, Arvi [1 ]
Barrett, Johnny [1 ]
Wang, Zhonghua [1 ]
Litvin, Andrew [2 ]
Hamadeh, Ali [2 ]
Beaudet, Daniel [2 ]
机构
[1] GE Healthcare Surg, 384 Wright Brothers Dr, Salt Lake City, UT 84116 USA
[2] GE Healthcare Surg, Lawrence, MA 01843 USA
关键词
mobile C-arm; calibration; motorized motion; electromagnetic tracking;
D O I
10.1117/12.711798
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The design of mobile X-ray C-arm equipment with image tomography and surgical guidance capabilities involves the retrieval of repeatable gantry positioning in three-dimensional space. Geometry misrepresentations can cause degradation of the reconstruction results with the appearance of blurred edges, image artifacts, and even false structures. It may also amplify surgical instrument tracking errors leading to improper implant placement. In our prior publications we have proposed a C-arm 3D positioner calibration method comprising separate intrinsic and extrinsic geometry calibration steps. Following this approach, in the present paper, we extend the intrinsic geometry calibration of C-gantry beyond angular positions in the orbital plane into angular positions on a unit sphere of isocentric rotation. Our method makes deployment of markerless interventional tool guidance with use of high-resolution fluoro images and electromagnetic tracking feasible at any angular position of the tube-detector assembly. Variations of the intrinsic parameters associated with C-arm motion are measured off-line as functions of orbital and lateral angles. The proposed calibration procedure provides better accuracy, and prevents unnecessary workflow steps for surgical navigation applications. With a slight modification, the Misalignment phantom, a tool for intrinsic geometry calibration, is also utilized to obtain an accurate 'image-to-sensor' mapping. We show simulation results, image quality and navigation accuracy estimates, and feasibility data acquired with the prototype system. The experimental results show the potential of high-resolution CT imaging (voxel size below 0.5 mm) and confident navigation in an interventional surgery setting with a mobile C-arm.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [2] Mobile C-arm 3D Reconstruction in the Presence of Uncertain Geometry
    Rottman, Caleb
    McBride, Lance
    Cheryauka, Arvidas
    Whitaker, Ross
    Joshi, Sarang
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 692 - 699
  • [3] Sequential intrinsic and extrinsic geometry calibration in fluoro CT imaging with a mobile C-arm
    Cheryauka, Arvi
    Breham, Sebastien
    Christensen, Wayne
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [4] 3-D Model Reconstruction from C-arm Images
    Chen, Yan-Ru
    Lin, Huei-Yung
    Wang, Min-Liang
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 2454 - 2459
  • [5] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [6] In room tracking of mobile C-arm for patient setup verification
    Sorensen, SP
    Mitschke, M
    Medin, P
    Tenn, S
    Chow, P
    Wink, N
    Solberg, TD
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S391 - S391
  • [7] Automatic measurements of image geometry for online calibration of C-arm fluoroscopy
    Archip, N
    Rohling, R
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2498 - 2500
  • [8] A Realistic X-Ray Simulation for C-Arm Geometry Calibration
    Thuerauf, Sabine
    Wolf, Markus
    Koerner, Mario
    Vogt, Florian
    Hornung, Oliver
    Nasseri, M. Ali
    Knoll, Alois
    [J]. 2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2016, : 383 - 388
  • [9] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697
  • [10] Online geometrical calibration of a mobile C-arm using external sensors
    Mitschke, MM
    Navab, N
    Schütz, O
    [J]. MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 : 580 - 587