Online geometrical calibration of a mobile C-arm using external sensors

被引:5
|
作者
Mitschke, MM [1 ]
Navab, N [1 ]
Schütz, O [1 ]
机构
[1] Siemens AG Med Engn GT1, D-91052 Erlangen, Germany
关键词
3D tomographic reconstruction; X-ray C-arm systems; external tracking systems; recovery of projection geometry;
D O I
10.1117/12.383086
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D tomographic reconstruction of high contrast objects such as contrast agent enhanced brood vessels or banes from Xray images acquired by isocentric Carm systems recently gained interest. For tomographic reconstruction, a sequence of images is captured during the Garm rotation around the patient and the precise projection geometry has to be determined for each image. This is a difficult task, as Germs usually do not provide accurate information about their projection geometry. Standard methods propose the use of an X-ray calibration phantom and an offline calibration, when the motion of the C-arm is supposed to be reproducible between calibration and patient run. However, mobile C-arms usually do not have this desirable property. Therefore, an online recovery of projection geometry is necessary. Here, we study the use of external tracking systems, such as Polaris or Optotrak from Northern Digital, Inc., for online calibration. In order to use the external tracking system for recovery of X-ray projection geometry two unknown transformations have to be estimated. We describe our attempt to solve this calibration problem. These are the relations between X-ray imaging system and marker plate of the tracking system as well as world and sensor coordinate system. Experimental results on anatomical data are presented and visually compared with the results of estimating the projection geometry with an X-ray calibration phantom.
引用
收藏
页码:580 / 587
页数:8
相关论文
共 50 条
  • [1] Online mobile C-arm calibration using inertial sensors: a preliminary study in order to achieve CBCT
    Lemammer, Imane
    Michel, Olivier
    Ayasso, Hacheme
    Zozor, Steeve
    Bernard, Guillaume
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (02) : 213 - 224
  • [2] Online mobile C-arm calibration using inertial sensors: a preliminary study in order to achieve CBCT
    Imane Lemammer
    Olivier Michel
    Hacheme Ayasso
    Steeve Zozor
    Guillaume Bernard
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 213 - 224
  • [3] On-the-fly geometrical calibration fine-tuning of a mobile C-arm CBCT system
    El Hakimi, Wissam
    Sakas, Georgios
    TM-TECHNISCHES MESSEN, 2016, 83 (05) : 300 - 308
  • [4] A Geometrical Calibration Method for C-Arm CT Based on a Nonlinear Registration Model
    Ji, Xu
    Lu, Yuchen
    Zhuo, Xu
    Zhang, Yikun
    Zhu, Shiyu
    Chen, Yang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [5] Tomosynthesis implementation with adaptive online calibration on clinical C-arm systems
    Khanlian Chung
    Lothar R. Schad
    Frank G. Zöllner
    International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 1481 - 1495
  • [6] Automatic measurements of image geometry for online calibration of C-arm fluoroscopy
    Archip, N
    Rohling, R
    MEDICAL PHYSICS, 2004, 31 (09) : 2498 - 2500
  • [7] Video-guided calibration of an augmented reality mobile C-arm
    Chen, Xin
    Naik, Hemal
    Wang, Lejing
    Navab, Nassir
    Fallavollita, Pascal
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (06) : 987 - 996
  • [8] Video-guided calibration of an augmented reality mobile C-arm
    Xin Chen
    Hemal Naik
    Lejing Wang
    Nassir Navab
    Pascal Fallavollita
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 987 - 996
  • [9] C-arm calibration - Is it really necessary?
    Jain, A
    Kon, R
    Zhou, Y
    Fichtinger, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 639 - 646
  • [10] C-arm calibration - is it really necessary?
    Jain, Ameet Kumar
    An, Michael
    Chitphakdithai, Nicha
    Chintalapani, Gouthami
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509