Attachment Systems for Mandibular Single-Implant Overdentures: An In Vitro Retention Force Investigation on Different Designs

被引:0
|
作者
Alsabeeha, Nabeel [1 ]
Atieh, Momen [1 ]
Swain, Michael V. [1 ]
Payne, Alan G. T. [1 ]
机构
[1] Univ Otago, Sch Dent, Sir John Walsh Res Inst, Oral Implantol Res Grp, Dunedin, New Zealand
关键词
PROSPECTIVE CLINICAL-EVALUATION; PATIENT SATISFACTION; COMPLETE DENTURES; INTERIMPLANT DISTANCE; EDENTULOUS PATIENT; BAR-CLIP; STABILITY; TRIAL; BALL; PREFERENCE;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the retentive force of six different attachment systems used for mandibular single-implant overdentures, including two prototype large ball attachment designs. Materials and Methods: Two prototype ball attachments of larger dimensions (7.9 and 5.9 mm) and four commercially available ball and stud attachments of standard dimensions (2.25 and 4.0 mm) were evaluated on three identical test casts resembling an edentulous mandible with severe residual ridge resorption. Five samples from each attachment system (n = 30) were connected to three different implants (8.0-mm wide diameter, 3.75-mm regular diameter, and 4.0-mm regular diameter). An Instron testing machine with a computer software package was used to deliver a vertical dislodging force at a cross-head speed of 50 mm/min to each overdenture sample from the anterior direction. A total of 300 pull tests were conducted (50 per attachment system). The maximum load (retentive force) required to separate each overdenture from the supporting implant was then measured. Results: The highest retentive force (36.97 +/- 2.23 N) was achieved with the 7.9-mm prototype ball attachment design, followed in a decreasing order by the 5.9-mm prototype ball attachment design (32.06 +/- 2.59 N), the standard 2.25-mm ball attachment (17.32 +/- 3.68 N), Locator white (12.39 +/- 0.55 N), Locator pink (9.40 N +/- 0.74 N), and Locator blue (3.83 +/- 0.64 N). A statistically significant difference (P < .0001) was found between all attachments. Conclusions: Attachment systems of larger dimensions provided higher retentive forces for mandibular single-implant overdentures. Further in vitro and in vivo research is necessary to determine prosthodontic outcomes with these attachments in edentulous patients prior to their routine clinical use internationally. Int J Prosthodont 2010;23:160-166.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 50 条
  • [21] Patient Satisfaction with Maxillary 3-Implant Overdentures Using Different Attachment Systems Opposing Mandibular 2-Implant Overdentures
    Al-Zubeidi, Mohammed I.
    Alsabeeha, Nabeel H. M.
    Thomson, W. Murray
    Payne, Alan G. T.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e11 - e19
  • [22] An in vitro Investigation into Retention Strength and Fatigue Resistance of Various Designs of Tooth/Implant Supported Overdentures
    Fatalla, Abdalbseet A.
    Song, Ke
    Du, Tianfeng
    Cao, Yingguang
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (01) : 124 - 129
  • [23] Effect of Implant Angulation on Attachment Retention in Mandibular Two-Implant Overdentures: A Clinical Study
    Jabbour, Zaher
    Fromentin, Olivier
    Lassauzay, Claire
    Nader, Samer Abi
    Correa, Jose A.
    Feine, Jocelyne
    de Albuquerque, Rubens F., Jr.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (04) : 565 - 571
  • [24] An in vitro Investigation into Retention Strength and Fatigue Resistance of Various Designs of Tooth/Implant Supported Overdentures
    Abdalbseet A Fatalla
    宋珂
    杜田丰
    曹颖光
    Current Medical Science, 2012, (01) : 124 - 129
  • [25] An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures
    Abdalbseet A. Fatalla
    Ke Song
    Tianfeng Du
    Yingguang Cao
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 124 - 129
  • [26] Retention force of Molloplast-B with ball attachment in implant-supported overdentures: An in vitro study
    Salloum, Alaa'a
    Alassafeen, Ammar
    Kassis, Joul
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (03) : 268 - 271
  • [27] In vitro comparison of change in retentive force values of three different attachment systems for two implant-supported overdentures
    Fernandes, Donato Savio
    Anasane, Nayana S.
    Jagtap, Amit K.
    Fernandes, Christie Michael
    FRONTIERS OF ORAL AND MAXILLOFACIAL MEDICINE, 2025, 7
  • [28] Effect of Labial Implant Inclination on the Retention and Stability of Different Resilient Stud Attachments for Mandibular Implant Overdentures: An In Vitro Study
    ELsyad, Moustafa Abdou
    Emera, Radwa M. K.
    Ibrahim, Abdullah Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 381 - 389
  • [29] Single-Implant Overdentures Retained by a Novel Attachment: A Mixed Methods Crossover Randomized Clinical Trial
    de Souza, R. F.
    Jabbar, A. A.
    Jafarpour, D.
    Bedos, C.
    Esfandiari, S.
    Makhoul, N. M.
    Dagdeviren, D.
    Nader, S. Abi
    Feine, J. S.
    JDR CLINICAL & TRANSLATIONAL RESEARCH, 2024, 9 (01) : 27 - 41
  • [30] Mandibular Two-Implant Overdentures: Prosthodontic Maintenance Using Different Loading Protocols and Attachment Systems
    Mackie, Andrew
    Lyons, Karl
    Thomson, W. Murray
    Payne, Alan G. T.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (05) : 405 - 416