Clinical implementation of varian enhanced dynamic wedges into the pinnacle treatment planning system: Monte Carlo dosimetry and patient-specific quality assurance techniques

被引:0
|
作者
Ahmad, M.
Deng, J.
Chen, Z.
Lund, M.
Kimmett, J.
Moran, M.
Nath, R.
机构
[1] Yale Univ, Sch Med, New Haven, CT USA
[2] Yale New Haven Med Ctr, New Haven, CT 06504 USA
[3] William W Backus Hosp, Norwich, NY USA
关键词
D O I
10.1118/1.2760762
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a commissioning study of enhanced dynamic wedges (EDWs) into the Pinnacle3 treatment planning system (TPS) and to evaluate various QA techniques for validating the treatment plans using EDWs. Method and Materials: Dose distribution modeling for EDW fields in the Pinnacle3 TPS is based on a combination of open‐field beam data and the Varian “Golden Segmented Treatment Table” (GSTT) unique to each photon beam. To validate the EDW models, dose profiles of 6− and 10−MV photon beams from a Clinac 2100C/D were measured in water for depths from near‐surface to 31.5 cm for a wide range of field sizes and wedge angles using a linear detector array of 25 energy‐compensated diodes (LDA‐25) to integrate the dose at multiple points in the EDW field for each exposure. The EDW output factors for square fields from 4 to 20 cm wide were measured in solid water using a cylindrical ionization chamber at a depth of 10 cm on central axis. The 6− and 10−MV photon beams emerging from the treatment head of the Clinac 2100C/D were fully simulated using the BEAMnrc and DOSXYZnrc was used to calculate the central‐axis percentage depth doses and dose profiles for the open and dynamically‐wedged fields in a water phantom. Film and MapCHECK data were compared with Pinnacle3 and MC predictions. Results: (1) Pinnacle collapsed‐cone convolution algorithm and MC simulations agreed with the measured EDW dose distributions to an accuracy of better than 3%. (2) Measured EDW output factors used for monitor‐unit calculation in Pinnacle3 TPS agreed with the MC predictions within 1–2%. (3) EDW‐based treatment plans were satisfactorily validated using MapCHECK and chamber measurements. Conclusions: We have successfully modeled EDWs into the Pinnacle3 TPS and demonstrated that MapCHECK and films dosimetry constitute valuable QA tools for validating planned dose distributions resulting from dynamically‐wedged beams. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2425 / 2425
页数:1
相关论文
共 50 条
  • [31] Implementation of An In-House Radiochromic Film Dosimetry Software for Patient Specific Treatment Plan Quality Assurance
    Schurr, R.
    Park, J.
    Kim, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2954 - 2955
  • [32] VERIFICATION AND CLINICAL IMPLEMENTATION OF A COMMERCIAL MONTE CARLO TREATMENT PLANNING SYSTEM FOR ELECTRON BEAMS
    Cygler, J.
    Vandervoort, E.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S523 - S523
  • [33] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [34] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric-Modulated Arc Therapy (VMAT): Clinical and Educational Impacts
    Chen, X.
    Xing, L.
    Mok, E.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy
    Changhwan Kim
    Min Cheol Han
    Young Kyu Lee
    Han-Back Shin
    Hojin Kim
    Jin Sung Kim
    Radiation Oncology, 17
  • [36] Clinical experience on patient-specific quality assurance for CBCT-based online adaptive treatment plan
    Shen, Chenyang
    Chen, Liyuan
    Zhong, Xinran
    Gonzalez, Yesenia
    Visak, Justin
    Meng, Boyu
    Inam, Enobong
    Parsons, David
    Godley, Andrew
    Jiang, Steve
    Cai, Bin
    Lin, Mu-Han
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (04):
  • [37] Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy
    Kim, Changhwan
    Han, Min Cheol
    Lee, Young Kyu
    Shin, Han-Back
    Kim, Hojin
    Kim, Jin Sung
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [38] Evaluation of 4-Hz log files and secondary Monte Carlo dose calculation as patient-specific quality assurance for VMAT prostate plans
    Szeverinski, Philipp
    Kowatsch, Matthias
    Kunzler, Thomas
    Meinschad, Marco
    Clemens, Patrick
    DeVries, Alexander F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 235 - 244
  • [39] Pre-Treatment Patient Specific Quality Assurance for Brain Stereotactic Radiosurgery Patients Treated with Cones on the Varian Icvi System
    Olorunnisomo, I. O.
    Lewis, B.
    Forbang, R. Teboh
    Ndlovu, A. M.
    MEDICAL PHYSICS, 2024, 51 (10) : 7803 - 7803
  • [40] Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Fujita, Yukio
    Shimizu, Eiji
    Matsunaga, Kenichi
    Sawada, Kinya
    Matsushita, Haruo
    Majima, Kazuhiro
    Jingu, Keiichi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1220 - 1225