Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure

被引:28
|
作者
Mansouri, K. [1 ]
Sommerhalder, J. [1 ]
Shaarawy, T. [1 ]
机构
[1] Univ Geneva, Glaucoma Sectore, Dept Ophthalmol, CH-1211 Geneva, Switzerland
关键词
glaucoma; anterior-segment; optical coherence tomography; ultrasound biomicroscopy; angle closure; narrow angles; ASIAN EYES; LASER IRIDOTOMY; GLAUCOMA; INTRAOBSERVER; POPULATION; REPRODUCIBILITY; OCT; MORPHOLOGY; AGREEMENT; PEOPLE;
D O I
10.1038/eye.2009.103
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy in measurement of the anterior chamber (AC) angle by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in European patients with suspected primary angle closure (PACS), primary angle closure (PAC), or primary angle-closure glaucoma (PACG). Design Cross-sectional study. Methods In all, 55 eyes of 33 consecutive patients presenting with PACS, PAC, or PACG were examined with AS-OCT, followed by UBM. The trabecular-iris angle (TIA) was measured in all four quadrants. The angle-opening distance (AOD) was measured at 500 mu m from the scleral spur. The Bland-Altman method was used for assessing agreement between the two methods. Results The mean (+/- SD) superior TIA was 19.3 +/- 15.8 degrees in AS-OCT and 15.7 +/- 15.0 degrees in UBM (P = 0.50) and inferior TIA was 17.9 +/- 12.9 degrees (AS-OCT) and 16.7 +/- 14.1 degrees (UBM) (P = 0.71). The superior AOD(500) was 0.17 +/- 0.16mm in UBM and 0.21 +/- 0.16mm in AS-OCT (P = 0.06). Bland-Altman analysis showed a mean SD of +/- 9.4 degrees for superior and inferior TIA and a mean SD of +/- 0.10mm for superior and inferior AOD(500). Conclusions This comparative study shows that AS-OCT measurements are significantly correlated with UBM measurements but show poor agreement with each other. We do not believe that AS-OCT can replace UBM for the quantitative assessment of the AC angle. Eye (2010) 24, 233-239; doi: 10.1038/eye.2009.103; published online 15 May 2009
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [31] Anterior Segment Optical Coherence Tomography Parameters in Subtypes of Primary Angle Closure
    Guzman, Celeste P.
    Gong, Tianxia
    Nongpiur, Monisha E.
    Perera, Shamira A.
    How, Alicia C.
    Lee, Hwee Kuan
    Cheng, Li
    He, Mingguang
    Baskaran, Mani
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5281 - 5286
  • [32] Anterior Segment Imaging: Optical Coherence Tomography Versus Ultrasound Biomicroscopy
    Garcia, Julian P. S., Jr.
    Rosen, Richard B.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (06) : 476 - 484
  • [33] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [34] Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure
    Baskaran, Mani
    Aung, Tin
    Friedman, David S.
    Tun, Tin A.
    Perera, Shamira A.
    ACTA OPHTHALMOLOGICA, 2012, 90 (08) : e621 - e625
  • [35] Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle
    Sakata, Lisandro M.
    Lavanya, Raghavan
    Friedman, David S.
    Aung, Han T.
    Gao, Hong
    Kumar, Rajesh S.
    Foster, Paul J.
    Aung, Tin
    OPHTHALMOLOGY, 2008, 115 (05) : 769 - 774
  • [36] Subclassification of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopic Parameters
    Kwon, Junki
    Sung, Kyung Rim
    Han, Seungbong
    Moon, Ye Ji
    Shin, Joong Won
    OPHTHALMOLOGY, 2017, 124 (07) : 1039 - 1047
  • [37] Comparison of ultrasound biomicroscopy and spectral-domain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy
    Ma, Xiao-Yun
    Zhu, Dan
    Zou, Jun
    Zhang, Wen-Jie
    Cao, Yi-Lin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (03) : 417 - 423
  • [38] Acute angle closure: qualitative and quantitative evaluation of the anterior segment using anterior segment optical coherence tomography
    Moghimi, Sasan
    Zandvakil, Narges
    Vahedian, Zakieh
    Mohammadi, Massood
    Fakhraie, Ghasem
    Coleman, Anne L.
    Lin, Shan C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07): : 615 - 622
  • [39] Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease
    Angmo, Dewang
    Singh, Reena
    Chaurasia, Shweta
    Yadav, Suresh
    Dada, Tanuj
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (04) : 500 - 504
  • [40] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368