Anterior Segment Optical Coherence Tomography Parameters in Subtypes of Primary Angle Closure

被引:79
|
作者
Guzman, Celeste P. [1 ]
Gong, Tianxia [2 ]
Nongpiur, Monisha E. [1 ]
Perera, Shamira A. [1 ]
How, Alicia C. [1 ]
Lee, Hwee Kuan [2 ]
Cheng, Li [2 ]
He, Mingguang [3 ]
Baskaran, Mani [1 ]
Aung, Tin [1 ,4 ,5 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] ASTAR, Bioinformat Inst, Singapore, Singapore
[3] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510275, Guangdong, Peoples R China
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[5] Natl Univ Hlth Syst, Singapore, Singapore
基金
英国医学研究理事会; 新加坡国家研究基金会;
关键词
anterior segment optical coherence tomography; primary angle closure subtypes; lens vault; iris thickness; anterior chamber depth; GLAUCOMA; DETERMINANTS; ASSOCIATION; SINGAPORE; WIDTH;
D O I
10.1167/iovs.13-12285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare anterior segment parameters, assessed by anterior segment optical coherence tomography (ASOCT), in subjects categorized as primary angle closure suspect (PACS), primary angle closure (PAC), primary angle closure glaucoma (PACG), and previous acute PAC (APAC); and to identify factors associated with APAC. METHODS. This was a prospective ASOCT study of 425 subjects with angle closure (176 PACS, 66 PAC, 125 PACG, and 58 APAC). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750), trabecular-iris space area (TISA750), anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Mean differences in anterior segment parameters were evaluated by analysis of covariance (ANCOVA) adjusted for age, sex, and pupil diameter (PD). RESULTS. Comparison among the different subgroups showed that ACD, ACA, and ACV were smallest, and IT750 thickest in the APAC group compared with the other subgroups (P < 0.001). LV was greatest in the APAC group (1218 +/- 34 mu m) followed by PAC (860 6 31 mu m), PACG (845 +/- 23 mu m), and PACS (804 +/- 19 mu m), respectively (P = <0.001). While the APAC group had the narrowest angles, the PACS group had the widest (P < 0.001 for both AOD750 and TISA750). Logistic regression showed that greater LV (P = <0.001), narrower TISA750 (P = <0.001), and thicker IT750 (P = 0.007) were the major determinants of APAC. CONCLUSIONS. Eyes with APAC had the narrowest angles, smallest anterior segment dimensions, thickest iris, and largest LV compared with PACS, PAC, and PACG. LV, TISA750, and IT750 were the major determinants of APAC.
引用
收藏
页码:5281 / 5286
页数:6
相关论文
共 50 条
  • [1] Anterior segment optical coherence tomography in subtypes of angle closure glaucoma
    Nouri-Mahdavi, Kouros
    [J]. JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 159 - 160
  • [2] Anterior segment optical coherence tomography of acute primary angle closure
    Zhang, Hai Tao
    Xu, Liang
    Cao, Wei Fang
    Wang, Ya Xing
    Jonas, Jost B.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 825 - 831
  • [3] Anterior segment optical coherence tomography of acute primary angle closure
    Hai Tao Zhang
    Liang Xu
    Wei Fang Cao
    Ya Xing Wang
    Jost B. Jonas
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 825 - 831
  • [4] Comparative evaluation of anterior segment parameters in subgroups of primary angle closure using anterior segment optical coherence tomography
    Guzman, Celeste
    Gong, Tianxia
    Nongpiur, Monisha
    Perera, Shamira
    Lee, Hwee Kuan
    Li, Cheng
    Mani, Baskaran
    He, Mingguang
    How, Alicia
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Ocular Biometry in the Subtypes of Angle Closure: An Anterior Segment Optical Coherence Tomography Study
    Moghimi, Sasan
    Vahedian, Zakieh
    Fakhraie, Ghasem
    Ghaffari, Reza
    Eslami, Yadollah
    Jabarvand, Mahmood
    Zarei, Reza
    Mohammadi, Massood
    Lin, Shan
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 664 - 673
  • [6] Subgrouping of Primary Angle-Closure Suspects Based on Anterior Segment Optical Coherence Tomography Parameters
    Nongpiur, Monisha E.
    Gong, Tianxia
    Lee, Hwee Kuan
    Perera, Shamira A.
    Cheng, Li
    Foo, Li-Lian
    He, Mingguang
    Friedman, David S.
    Aung, Tin
    [J]. OPHTHALMOLOGY, 2013, 120 (12) : 2525 - 2531
  • [7] Corneal hysteresis and anterior segment optical coherence tomography anatomical parameters in primary angle closure suspects
    Hussnain, Syed Amal
    Kovacs, Kyle D.
    Warren, Joshua L.
    Teng, Christopher C.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (05): : 468 - 472
  • [8] Subclassification of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopic Parameters
    Kwon, Junki
    Sung, Kyung Rim
    Han, Seungbong
    Moon, Ye Ji
    Shin, Joong Won
    [J]. OPHTHALMOLOGY, 2017, 124 (07) : 1039 - 1047
  • [9] Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms
    Shabana, Noor
    Aquino, Maria C. D.
    See, Jovina
    Ce, Zheng
    Tan, Anna M.
    Nolan, Winifred P.
    Hitchings, Roger
    Young, Stephanie M.
    Loon, Seng Chee
    Sng, Chelvin C.
    Wong, Wanling
    Chew, Paul T. K.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (08): : 792 - 801
  • [10] Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease
    Angmo, Dewang
    Singh, Reena
    Chaurasia, Shweta
    Yadav, Suresh
    Dada, Tanuj
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (04) : 500 - 504