Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure

被引:28
|
作者
Mansouri, K. [1 ]
Sommerhalder, J. [1 ]
Shaarawy, T. [1 ]
机构
[1] Univ Geneva, Glaucoma Sectore, Dept Ophthalmol, CH-1211 Geneva, Switzerland
关键词
glaucoma; anterior-segment; optical coherence tomography; ultrasound biomicroscopy; angle closure; narrow angles; ASIAN EYES; LASER IRIDOTOMY; GLAUCOMA; INTRAOBSERVER; POPULATION; REPRODUCIBILITY; OCT; MORPHOLOGY; AGREEMENT; PEOPLE;
D O I
10.1038/eye.2009.103
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy in measurement of the anterior chamber (AC) angle by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in European patients with suspected primary angle closure (PACS), primary angle closure (PAC), or primary angle-closure glaucoma (PACG). Design Cross-sectional study. Methods In all, 55 eyes of 33 consecutive patients presenting with PACS, PAC, or PACG were examined with AS-OCT, followed by UBM. The trabecular-iris angle (TIA) was measured in all four quadrants. The angle-opening distance (AOD) was measured at 500 mu m from the scleral spur. The Bland-Altman method was used for assessing agreement between the two methods. Results The mean (+/- SD) superior TIA was 19.3 +/- 15.8 degrees in AS-OCT and 15.7 +/- 15.0 degrees in UBM (P = 0.50) and inferior TIA was 17.9 +/- 12.9 degrees (AS-OCT) and 16.7 +/- 14.1 degrees (UBM) (P = 0.71). The superior AOD(500) was 0.17 +/- 0.16mm in UBM and 0.21 +/- 0.16mm in AS-OCT (P = 0.06). Bland-Altman analysis showed a mean SD of +/- 9.4 degrees for superior and inferior TIA and a mean SD of +/- 0.10mm for superior and inferior AOD(500). Conclusions This comparative study shows that AS-OCT measurements are significantly correlated with UBM measurements but show poor agreement with each other. We do not believe that AS-OCT can replace UBM for the quantitative assessment of the AC angle. Eye (2010) 24, 233-239; doi: 10.1038/eye.2009.103; published online 15 May 2009
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [21] Comparative evaluation of anterior segment parameters in subgroups of primary angle closure using anterior segment optical coherence tomography
    Guzman, Celeste
    Gong, Tianxia
    Nongpiur, Monisha
    Perera, Shamira
    Lee, Hwee Kuan
    Li, Cheng
    Mani, Baskaran
    He, Mingguang
    How, Alicia
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [22] Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes
    Moghimi, Sasan
    Ramezani, Farshid
    He, Mingguang
    Coleman, Anne L.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 7611 - 7617
  • [23] Comparison of anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) in diagnosis of anterior scleritis
    Purgert, Robert
    Bessette, Angela
    Pichi, Francesco
    Lowder, Careen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma
    Qianwen Bu
    Die Hu
    Hai Zhu
    Jianhong Jiang
    Ying Su
    Jingyi Wu
    Zongyi Li
    Xiaojing Pan
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1651 - 1658
  • [25] Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma
    Bu, Qianwen
    Hu, Die
    Zhu, Hai
    Jiang, Jianhong
    Su, Ying
    Wu, Jingyi
    Li, Zongyi
    Pan, Xiaojing
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (6) : 1651 - 1658
  • [26] Comparison of anterior segment in nanophthalmic eyes with secondary chronic angle closure glaucoma and eyes with chronic primary angle closure glaucoma: an ultrasound biomicroscopy study
    Li, Zhongwen
    Zhao, Zhenni
    Liu, Jiafan
    Li, Jianlong
    Guo, Congcong
    Zhang, Jiamin
    Zhang, Dandan
    Fan, Zhigang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [27] Qualitative evaluation of anterior segment in angle closure disease using anterior segment optical coherence tomography
    Moghimi, Sasan
    Chen, Rebecca
    Hamzeh, Nikoo
    Khatibi, Nassim
    Lin, Shan C.
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 170 - 175
  • [28] Effect of Body Position on Anterior Chamber Angle Dimensions Assessed by Anterior Segment Optical Coherence Tomography
    Penteado, Rafaella
    Xu, Benjamin
    Yang, Diya
    Proudfoot, James
    Susanna, Remo
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [29] Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    Radhakrishnan, S
    Goldsmith, J
    Huang, D
    Westphal, V
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) : 1053 - 1059
  • [30] Comparison of immersion ultrasonography, ultrasound biomicroscopy and anterior segment optical coherence tomography in the evaluation of traumatic phacoceles
    Vodapalli, Harikrishna
    Murthy, Somasheila I.
    Jalali, Subhadra
    Ali, Mohammad Javed
    Rani, Padmaja Kumari
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (01) : 63 - 65