Comparison of Josephson array voltage standards using Zener reference standards

被引:0
|
作者
Gengru, Z
Yifei, H
Lu, W
Guifen, Z
Jensen, HD
Henderson, LCA
Thompson, RP
机构
[1] Beijing Inst Radio Metrol & Measurement, Beijing 100854, Peoples R China
[2] Danish Inst Fundamental Metrol, DK-2800 Lyngby, Denmark
[3] Natl Phys Lab, Ctr Electromagnet & Time Metrol, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0026-1394/34/5/7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Josephson array voltage standard at the Beijing Institute of Radio Metrology and Measurement (BIRMM) has been used in China to realize the volt since 1992. In order to verify the accuracy and reliability of the voltage standard at the BIRMM, a comparison of the Josephson array voltage standards at 1,018 V and 10 V between the BIRMM, the Danish Institute of Fundamental Metrology (DFM) and the National Physical Laboratory (NPL), UK, has been performed. Two Zener reference standards were used to transfer the voltage between the three laboratories. The results show a difference of less than 2x10(-8).
引用
收藏
页码:423 / 425
页数:3
相关论文
共 50 条
  • [1] A direct comparison of Josephson Array Voltage Standards
    Liu, L. X.
    Chua, S. W.
    Lee, J.
    Zhou, Y.
    Hamilton, C. A.
    [J]. 2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 368 - +
  • [2] Using 10 V Josephson voltage standards to estimate the uncertainty of Zener voltage references as travelling standards
    Lo-Hive, JP
    Reymann, D
    Geneves, G
    [J]. 1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 349 - 350
  • [3] Using 10 V Josephson voltage standards to estimate the uncertainty of Zener voltage references as traveling standards
    Lo-Hive, JP
    Reymann, D
    Genevès, G
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 253 - 256
  • [4] COMPARISON OF JOSEPHSON SERIES-ARRAY VOLTAGE STANDARDS
    NIEMEYER, J
    GRIMM, L
    MEIER, W
    FUNCK, T
    DUNSCHEDE, FW
    AUSBUTTEL, E
    HOLTOUG, JU
    MYGIND, J
    [J]. METROLOGIA, 1990, 27 (02) : 41 - 52
  • [5] REALIZATIONS AND COMPARISONS OF JOSEPHSON ARRAY VOLTAGE STANDARDS
    WITT, TJ
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 208 - 210
  • [6] US INTERCOMPARISON OF JOSEPHSON ARRAY VOLTAGE STANDARDS
    RODRIGUEZ, KM
    HUNTLEY, L
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) : 215 - 218
  • [7] Quality Assurance for Josephson Array Voltage Standards
    Zhou, Yinzhu
    Chua, Sze Wey
    Lee, Jinni
    Shan, Yueyan
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) : 2578 - 2583
  • [8] INTERNATIONAL COMPARISONS OF JOSEPHSON ARRAY VOLTAGE STANDARDS
    REYMANN, D
    WITT, TJ
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 596 - 599
  • [9] SERIES-ARRAY JOSEPHSON VOLTAGE STANDARDS
    KAUTZ, RL
    HAMILTON, CA
    LLOYD, FL
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) : 883 - 890
  • [10] OPERATION OF NIST JOSEPHSON ARRAY VOLTAGE STANDARDS
    HAMILTON, CA
    BURROUGHS, C
    CHIEH, K
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (03) : 219 - 235