Comparison of Josephson array voltage standards using Zener reference standards

被引:0
|
作者
Gengru, Z
Yifei, H
Lu, W
Guifen, Z
Jensen, HD
Henderson, LCA
Thompson, RP
机构
[1] Beijing Inst Radio Metrol & Measurement, Beijing 100854, Peoples R China
[2] Danish Inst Fundamental Metrol, DK-2800 Lyngby, Denmark
[3] Natl Phys Lab, Ctr Electromagnet & Time Metrol, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0026-1394/34/5/7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Josephson array voltage standard at the Beijing Institute of Radio Metrology and Measurement (BIRMM) has been used in China to realize the volt since 1992. In order to verify the accuracy and reliability of the voltage standard at the BIRMM, a comparison of the Josephson array voltage standards at 1,018 V and 10 V between the BIRMM, the Danish Institute of Fundamental Metrology (DFM) and the National Physical Laboratory (NPL), UK, has been performed. Two Zener reference standards were used to transfer the voltage between the three laboratories. The results show a difference of less than 2x10(-8).
引用
收藏
页码:423 / 425
页数:3
相关论文
共 50 条
  • [31] Josephson voltage standards - A review
    Hamilton, CA
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 335 - 336
  • [32] Broadband Josephson voltage standards
    Hamilton, CA
    Benz, SP
    [J]. 2001 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2001, : 853 - 856
  • [33] THE JOSEPHSON EFFECT AND VOLTAGE STANDARDS
    POPEL, R
    [J]. METROLOGIA, 1992, 29 (02) : 153 - 174
  • [34] Maintenance of the reference volt using standard cells and Zener standards
    de Silva, GMS
    [J]. METROLOGY - AT THE THRESHOLD OF THE CENTURY ARE WE READY?, 1999, : 109 - 109
  • [35] COMPARISON OF NIM AND BIRMM PROGRAMMABLE JOSEPHSON VOLTAGE STANDARDS.
    Gao, Yuan
    Li, Honghui
    Wang, Zengmin
    Kang, Yan
    Wang, Lu
    Zhang, Hui
    Zhu, Zhu
    [J]. 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 52 - +
  • [36] Comparison between the SNS and SIS Josephson voltage standards at OFMET
    Jeanneret, B
    Rüfenacht, A
    Burroughs, CJ
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 389 - 390
  • [38] A COMPARISON OF ONE VOLT JOSEPHSON-JUNCTION ARRAY VOLTAGE STANDARDS DRIVEN BY A COMMON MICROWAVE SOURCE
    REYMANN, D
    LOHIVE, JP
    GENEVES, G
    [J]. METROLOGIA, 1994, 31 (01) : 35 - 37
  • [39] Indirect comparison of 10 V Josephson array voltage standards between the UME and BNM-LCIE
    Selçik, S
    Lo-Hive, JP
    Yilmaz, O
    Genevès, G
    [J]. METROLOGIA, 2001, 38 (05) : 477 - 480
  • [40] Evaluation of the performance of the zener diode reference as a transport standard of voltage at the national institute for standards
    El Rahman, A.H.A.
    [J]. Journal of Engineering and Applied Science, 2001, 48 (02): : 247 - 261