Using 10 V Josephson voltage standards to estimate the uncertainty of Zener voltage references as traveling standards

被引:0
|
作者
Lo-Hive, JP [1 ]
Reymann, D
Genevès, G
机构
[1] BNM, LCIE, F-92260 Fontenay Aux Roses, France
[2] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
Josephson array; Josephson standard; voltage measurement; Zener voltage reference;
D O I
10.1109/19.769576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In anticipation of a European comparison of 10 V Josephson array voltage standards (EUROMET project 429 led by the NMi VSL), the BIPM and the BNM-LCIE Josephson standards have been compared by means of Zener traveling references. A mean difference of 5 parts in 10(9) has been found with a standard uncertainty of 6 parts in 10(9). The results show that the performance of the Zener references could be the main cause of uncertainty in such a comparison.
引用
收藏
页码:253 / 256
页数:4
相关论文
共 50 条
  • [1] Using 10 V Josephson voltage standards to estimate the uncertainty of Zener voltage references as travelling standards
    Lo-Hive, JP
    Reymann, D
    Geneves, G
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 349 - 350
  • [2] Calibration System for Zener Voltage Standards Using a 10 V Programmable Josephson Voltage Standard at NMIJ
    Maruyama, Michitaka
    Iwasa, Akio
    Yamamori, Hirotake
    Chen, Shih-Fang
    Urano, Chiharu
    Kaneko, Nobu-hisa
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) : 1606 - 1612
  • [3] Comparison of Josephson array voltage standards using Zener reference standards
    Gengru, Z
    Yifei, H
    Lu, W
    Guifen, Z
    Jensen, HD
    Henderson, LCA
    Thompson, RP
    METROLOGIA, 1997, 34 (05) : 423 - 425
  • [4] Evaluating the uncertainty of Josephson voltage standards
    Hamilton, CA
    Tang, YH
    METROLOGIA, 1999, 36 (01) : 53 - 58
  • [5] Improvements in the Inmetro Zener Calibration Uncertainty Budgets Using Conventional and Programmable Josephson Voltage Standards
    Landim, R. P.
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [6] Application of a 10 V Programmable Josephson Voltage Standard in Direct Comparison With Conventional Josephson Voltage Standards
    Tang, Yi-Hua
    Wachter, James
    Ruefenacht, Alain
    FitzPatrick, Gerald J.
    Benz, Samuel P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (12) : 3458 - 3466
  • [7] Josephson voltage standards
    Hamilton, CA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (10): : 3611 - 3623
  • [8] Josephson voltage standards
    Kohlmann, J
    Behr, R
    Funck, T
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (08) : 1216 - 1228
  • [9] North American interlaboratory comparison of 10 V Josephson voltage standards
    Deaver, D
    Miller, WB
    Pardo, L
    Jaeger, K
    Plowman, D
    Hamilton, CA
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 249 - 250
  • [10] Comparison of the 10 V josephson voltage standards of the conventional and the programmable at NIM
    Li Honghui
    Gao Yuan
    Wang Zengmin
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 2, 2015, : 713 - 717