Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus

被引:195
|
作者
Tanner, Rebecca K. [1 ]
Fuller, Kate L. [1 ]
Ross, Megan L. R. [2 ]
机构
[1] Australian Inst Sport, Natl Sport Sci Qual Assurance Program, Canberra, ACT 2616, Australia
[2] Australian Inst Sport, Canberra, ACT, Australia
关键词
Portable lactate analysers; Lactate pro; Lactate scout; Lactate plus; Accuracy; Reliability; Linearity; ANALOX GM7; PERFORMANCE; PARAMETERS;
D O I
10.1007/s00421-010-1379-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Three portable blood lactate analysers, Lactate Pro (LP), Lactate Scout (LS) and Lactate Plus (L(+)), were evaluated. Analyser reliability and accuracy was assessed. For reliability, intra- and inter-analyser comparisons demonstrated that the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra-TE = 0.4, inter-TE = 0.4 mM) displayed greater overall reliability than the LS (intra-TE = 1.0, inter-TE = 0.8 mM). At BLa < 4.0 mM, the LP (intra-TE = 0.1 mM) demonstrated greater reliability than the LS (intra-TE = 0.5 mM) and L(+) (intra-TE = 0.4 mM). At BLa > 8.0 mM, the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra- and inter-TE = 0.4 mM) displayed greater reliability than the LS (intra-TE = 1.1 mM, inter-TE = 0.9 mM). For accuracy, the L(+) (SEE = 0.6 mM) compared more favourably to the LP than the LS (SEE = 1.1 mM). At BLa similar to 1.0-18.0 mM, the LS produced values that were up to 0.9 mM higher than the LP; the L(+) produced BLa that were within +/- 0.1 mM. All portable analysers tended to under-read the ABL 700 analyser. The suitability of the LP and L(+) as accurate analysers is supported by strong correlations (r = 0.91 and r = 0.94) and limits of agreement a parts per thousand currency sign2.1 mM. This study showed that the LP and L(+), compared well to each other, displayed good reliability and accuracy when compared to a laboratory-based analyser. Although the LS also displayed relatively good reliability, it was not as reliable or accurate as the LP or L(+).
引用
收藏
页码:551 / 559
页数:9
相关论文
共 50 条
  • [41] EVALUATION OF THREE HANDHELD LACTATE METERS FOR MEASURING HEMOLYMPH L-LACTATE IN DECAPOD CRUSTACEANS
    Bakke, Snorre
    Woll, Astrid K.
    JOURNAL OF SHELLFISH RESEARCH, 2014, 33 (01): : 69 - 76
  • [42] Evaluation of a new portable system for cord lactate determination
    Yam, J
    Chua, S
    Razvi, K
    Arulkumaran, S
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1998, 45 (01) : 29 - 31
  • [43] Mortality Prediction with Lactate and Lactate Dehydrogenase
    Engin, Yasemin Zeynep
    Turhan, Kemal
    Yazagan, Asli
    Orem, Asim
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2015), PT I, 2015, 9043 : 78 - 84
  • [44] Changes in blood lactate and pyruvate concentrations and the lactate-to-pyruvate ratio during the lactate minimum speed test
    Carter, H
    Jones, AM
    Doust, JH
    JOURNAL OF SPORTS SCIENCES, 2000, 18 (03) : 213 - 225
  • [45] Validation of the Lactate Plus Lactate Meter in the Horse and Its Use in a Conditioning Program
    Hauss, Ashlee A.
    Stablein, Cortney K.
    Fisher, Allison L.
    Greene, Holly M.
    Nout-Lomas, Yvette S.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2014, 34 (09) : 1064 - 1068
  • [46] PLASMA-CATECHOLAMINES AND THEIR EFFECT ON BLOOD LACTATE AND MUSCLE LACTATE OUTPUT
    STAINSBY, WN
    SUMNERS, C
    ANDREW, GM
    JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) : 321 - 325
  • [47] Relationship between sweat lactate secretion rate and blood lactate concentration during exercise near the lactate threshold
    Yamagata, Takashi
    Shigemori, Yasushi
    GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE, 2022, 181 (11) : 833 - 840
  • [48] COMPATIBILITY OF CYCLIZINE LACTATE AND HALOPERIDOL LACTATE
    FAWCETT, JP
    WOODS, DJ
    MUNASIRI, B
    BECKET, G
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1994, 51 (18): : 2292 - 2292
  • [49] Blood lactate and lactate kinetics as treatment and prognosis markers for tissue hypoperfusion
    Verhaeghe, Marzia
    Hachimi-Idrissi, Said
    ACTA CLINICA BELGICA, 2020, 75 (01) : 1 - 8
  • [50] Effects of high and low blood lactate concentrations on sweat lactate response
    Green, JM
    Bishop, PA
    Muir, IH
    McLester, JR
    Heath, HE
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2000, 21 (08) : 556 - 560