Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus

被引:195
|
作者
Tanner, Rebecca K. [1 ]
Fuller, Kate L. [1 ]
Ross, Megan L. R. [2 ]
机构
[1] Australian Inst Sport, Natl Sport Sci Qual Assurance Program, Canberra, ACT 2616, Australia
[2] Australian Inst Sport, Canberra, ACT, Australia
关键词
Portable lactate analysers; Lactate pro; Lactate scout; Lactate plus; Accuracy; Reliability; Linearity; ANALOX GM7; PERFORMANCE; PARAMETERS;
D O I
10.1007/s00421-010-1379-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Three portable blood lactate analysers, Lactate Pro (LP), Lactate Scout (LS) and Lactate Plus (L(+)), were evaluated. Analyser reliability and accuracy was assessed. For reliability, intra- and inter-analyser comparisons demonstrated that the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra-TE = 0.4, inter-TE = 0.4 mM) displayed greater overall reliability than the LS (intra-TE = 1.0, inter-TE = 0.8 mM). At BLa < 4.0 mM, the LP (intra-TE = 0.1 mM) demonstrated greater reliability than the LS (intra-TE = 0.5 mM) and L(+) (intra-TE = 0.4 mM). At BLa > 8.0 mM, the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra- and inter-TE = 0.4 mM) displayed greater reliability than the LS (intra-TE = 1.1 mM, inter-TE = 0.9 mM). For accuracy, the L(+) (SEE = 0.6 mM) compared more favourably to the LP than the LS (SEE = 1.1 mM). At BLa similar to 1.0-18.0 mM, the LS produced values that were up to 0.9 mM higher than the LP; the L(+) produced BLa that were within +/- 0.1 mM. All portable analysers tended to under-read the ABL 700 analyser. The suitability of the LP and L(+) as accurate analysers is supported by strong correlations (r = 0.91 and r = 0.94) and limits of agreement a parts per thousand currency sign2.1 mM. This study showed that the LP and L(+), compared well to each other, displayed good reliability and accuracy when compared to a laboratory-based analyser. Although the LS also displayed relatively good reliability, it was not as reliable or accurate as the LP or L(+).
引用
收藏
页码:551 / 559
页数:9
相关论文
共 50 条
  • [31] BLOOD LACTATE AND LACTATE TOLERANCE LEVELS OF FUTSAL AND FOOTBALL PLAYERS
    Ocak, Yucel
    Baspinar, Sebiha G.
    Yildiz, Mehmet
    Ocak, Mustafa Furkan
    REVISTA BRASILEIRA DE FUTSAL E FUTEBOL, 2021, 13 (56): : 710 - 716
  • [32] Validation of the handheld Lactate-Pro analyzer for measurement of blood L-lactate concentration in cattle
    Buczinski, Sebastien
    Dore, Elizabeth
    Boulay, Guillaume
    Francoz, David
    VETERINARY CLINICAL PATHOLOGY, 2014, 43 (04) : 567 - 572
  • [33] BLOOD LACTATE AND SHOCK
    不详
    NUTRITION REVIEWS, 1964, 22 (07) : 203 - 205
  • [34] RELIABILITY OF LACTATE SCOUT PORTABLE ANALYZER IN AGILITY DOGS DURING MULTIPLE MEASUREMENTS
    Belic, Maja
    Radin, Lada
    Brkljaca Bottegaro, Nika
    Beer Ljubic, Blanka
    Benic, Marijan
    Stanin, Damir
    Vrbanac, Zoran
    ACTA VETERINARIA-BEOGRAD, 2016, 66 (04): : 549 - 555
  • [35] Comparison of the Nova StatStrip(R) Lactate versus the Arkray Lactate Pro(R) meters for fetal scalp lactate measurement
    Basso, Melanie
    Jung, Benjamin
    Wang, Li
    Kozak, Elvira
    Fernando, Ivy
    Halstead, Catherine
    Giesbrecht, Ellen
    CLINICAL BIOCHEMISTRY, 2014, 47 (12) : 1145 - 1146
  • [36] Evaluation of Lactate and Lactate Clearance as a Marker of Outcome in Trauma ICU
    Mishra, Manjaree
    Hakim, Mohammad Zeeshan
    Mishra, Shashi Prakash
    Saxena, Shobhit
    Trivedi, Nitesh
    ASIAN JOURNAL OF PHARMACEUTICAL RESEARCH AND HEALTH CARE, 2020, 12 (03) : 102 - 106
  • [37] Comparison of lactate measurements from earlobe and fingertip capillary blood using Biosen S-Line and lactate scout analyzers
    Zhong, Fogen
    Chen, Zhili
    Gu, Zhengqiu
    Wang, Xinxin
    Holmberg, Hans-Christer
    Li, Yongming
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2025, 125 (01) : 145 - 156
  • [38] Reliability and Accuracy of Six Hand-Held Blood Lactate Analysers
    Bonaventura, Jacinta M.
    Sharpe, Ken
    Knight, Emma
    Fuller, Kate L.
    Tanner, Rebecca K.
    Gore, Christopher J.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2015, 14 (01) : 203 - 214
  • [39] Validation of a Portable Hand-Held Lactate Analyzer for Determination of Blood Lactate in Patients on Antiretroviral Therapy in Uganda
    Kiragga, Agnes K.
    Ocama, Ponsiano
    Reynolds, Steven J.
    Kambugu, Andrew
    Ojiambo, Henry
    Castelnuovo, Barbara
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2008, 49 (05) : 564 - 566
  • [40] Role of mitochondrial lactate dehydrogenase and lactate oxidation in the intracellular lactate shuttle
    Brooks, GA
    Dubouchaud, H
    Brown, M
    Sicurello, JP
    Butz, CE
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (03) : 1129 - 1134