Biomechanical Analysis of Cervical Disc Replacement and Fusion Using Single Level, Two Level, and Hybrid Constructs

被引:58
|
作者
Gandhi, Anup A. [1 ,2 ]
Kode, Swathi [1 ,2 ]
DeVries, Nicole A. [1 ,2 ]
Grosland, Nicole M. [1 ,2 ,3 ]
Smucker, Joseph D. [3 ]
Fredericks, Douglas C. [3 ]
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Ctr Comp Aided Design, Iowa City, IA USA
[3] Univ Iowa, Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA USA
关键词
total disc replacement; arthroplasty; fusion; spine biomechanics; adjacent segment degeneration; BRYAN; PRESTIGE LP; arthrodesis; disc replacement plus fusion; range of motion; hybrid loading; TERM-FOLLOW-UP; INTERBODY FUSION; SPINE; ARTHROPLASTY; ADJACENT; RADICULOPATHY; ARTHRODESIS; DISKECTOMY;
D O I
10.1097/BRS.0000000000001044
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines. Objective. To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. Summary of Background Data. Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration. Methods. 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control). Results. An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels. Conclusion. Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.
引用
收藏
页码:1578 / 1585
页数:8
相关论文
共 50 条
  • [21] Biomechanical analysis of single- and double-level cervical disc arthroplasty using finite element modeling
    Rahman, Waseemur Ur
    Jiang, Wei
    Zhao, Fulin
    Li, Zhijun
    Wang, Guohua
    Yang, Guanghui
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2023, 237 (01) : 91 - 103
  • [22] The Mobi-C cervical disc for one-level and two-level cervical disc replacement: a review of the literature
    Alvin, Matthew D.
    Mroz, Thomas E.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2014, 7 (07): : 397 - 403
  • [23] Kinematics of Cervical Total Disc Replacement Adjacent to a Two-Level, Straight Versus Lordotic Fusion
    Martin, Shelden
    Ghanayem, Alexander J.
    Tzermiadianos, Michael N.
    Voronov, Leonard I.
    Havey, Robert M.
    Renner, Susan M.
    Carandang, Gerard
    Abjornson, Celeste
    Patwardhan, Avinash G.
    SPINE, 2011, 36 (17) : 1359 - 1366
  • [24] Outpatient and Inpatient Single-level Cervical Total Disc Replacement
    Segal, Dale N.
    Wilson, Jacob M.
    Staley, Christopher
    Yoon, S. Tim
    SPINE, 2019, 44 (01) : 79 - 83
  • [25] Biomechanical Analysis of the Cervical Spine Following Disc Degeneration, Disc Fusion, and Disc Replacement: A Finite Element Study
    Gandhi, Anup A.
    Grosland, Nicole M.
    Kallemeyn, Nicole A.
    Kode, Swathi
    Fredericks, Douglas C.
    Smucker, Joseph D.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2019, 13 (06): : 491 - 500
  • [26] The 5-year cost-effectiveness of two-level anterior cervical discectomy and fusion or cervical disc replacement: a Markov analysis
    Overley, Samuel C.
    McAnany, Steven J.
    Brochin, Robert L.
    Kim, Jun S.
    Merrill, Robert K.
    Qureshi, Sheeraz A.
    SPINE JOURNAL, 2018, 18 (01): : 63 - 71
  • [27] Arthroplasty versus fusion for single-level cervical disc disease
    Karabag, Hamza
    Cakmak, Erkan
    Celik, Bahattin
    Iplikcioglu, Ahmet Celal
    Soran, Ahmet Faruk
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2014, 64 (12) : 1348 - 1351
  • [28] Dynamic simulation of cervical spine following single-level cervical disc replacement
    de Jongh, Cornel U.
    Basson, Anton H.
    Scheffer, Cornie
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4289 - 4292
  • [29] Hybrid Strategy of Two-Level Cervical Artificial Disc and Intervertebral Cage Biomechanical Effects on Tissues and Implants
    Chung, Tzu-Tsao
    Hueng, Dueng-Yuan
    Lin, Shang-Chih
    MEDICINE, 2015, 94 (47) : e2048
  • [30] Biomechanical analysis of single and multi-level artificial disc replacement (ADR) in cervical spine using multi-scale loadings: A finite element study
    Kumar, Ram
    Kumar, Amit
    Kumari, Shabanam
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2024, 47 (06): : 411 - 417