Biomechanical Analysis of the Cervical Spine Following Disc Degeneration, Disc Fusion, and Disc Replacement: A Finite Element Study

被引:29
|
作者
Gandhi, Anup A. [1 ,2 ]
Grosland, Nicole M. [1 ,2 ]
Kallemeyn, Nicole A. [1 ,2 ]
Kode, Swathi [1 ,2 ]
Fredericks, Douglas C. [3 ]
Smucker, Joseph D. [3 ]
机构
[1] Univ Iowa, Univ Iowa Hosp & Clin, Dept Biomed Engn, Iowa City, IA USA
[2] Univ Iowa, Univ Iowa Hosp & Clin, Ctr Comp Aided Design, Iowa City, IA USA
[3] Univ Iowa, Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA USA
来源
关键词
TDR; arthroplasty; cervical spine; biomechanics; fusion; finite element analysis; disc replacement adjacent to fusion; Bryan disc; Prestige LP disc; adjacent segment; ARTHROPLASTY; PRESSURE; ANTERIOR; JOINT;
D O I
10.14444/6066
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Discectomy and fusion is considered the "gold standard'' treatment for clinical manifestations of degenerative disc disease in the cervical spine. However, clinical and biomechanical studies suggest that fusion may lead to adjacent-segment disease. Cervical disc arthroplasty preserves the motion at the operated level and may potentially decrease the occurrence of adjacent segment degeneration. The purpose of this study was to investigate the effect of disc generation, fusion, and disc replacement on the motion, disc stresses, and facet forces on the cervical spine by using the finite element method. Methods: A validated, intact, 3-dimensional finite element model of the cervical spine (C2-T1) was modified to simulate single-level (C5-C6) and 2-level (C5-C7) degeneration. The single-level degenerative model was modified to simulate both single-level fusion and arthroplasty (total disc replacement [TDR]) using the Bryan and Prestige LP discs. The 2-level degenerative model was modified to simulate a 2-level fusion, 2-level arthroplasty, and single-level disc replacement adjacent to single-level fusion (hybrid). The intact models were loaded by applying a moment of +/- 2 Nm in flexion-extension, lateral bending, and axial rotation. The motion in each direction was noted and the other modified models were loaded by increasing the moment until the primary C2-T1 motion matched that of the intact (healthy) C2-T1 motion. Results: Both Bryan and Prestige discs preserved motion at the implanted level and maintained normal motions at the adjacent nonoperative levels. A fusion resulted in a decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR (both) preserved motion adjacent to the fusion, thus reducing the demand on the other levels. The disc stresses followed the same trends as motion. Facet forces increased considerably at the index level following a TDR. Conclusion: The Bryan and Prestige LP TDRs both preserved motion at the implanted level and maintained normal motion and disc stresses at the adjacent levels. The motion patterns of the spine with a TDR more closely resembled that of the intact spine than those of the degenerative or fused models.
引用
收藏
页码:491 / 500
页数:10
相关论文
共 50 条
  • [1] BIOMECHANICAL STUDY OF THE CERVICAL SPINE WITH DISC IMPLANTS: A FINITE ELEMENT ANALYSIS
    Szkoda, K.
    Galaska, P.
    Zak, M.
    Pezowicz, C.
    [J]. ENGINEERING MECHANICS 2017, 2017, : 966 - 969
  • [2] Adjacent level effects of bi level disc replacement, hi level fusion and disc replacement plus fusion in cervical spine- a finite element based study
    Faizan, Ahmad
    Goel, Vijay K.
    Biyani, Ashok
    Garfin, Steven R.
    Bono, Christopher M.
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (03) : 226 - 233
  • [3] FINITE ELEMENT ANALYSIS OF CERVICAL SPINE WITH DIFFERENT CONSTRAINED TYPES OF TOTAL DISC REPLACEMENT
    Lin, Chien-Yu
    Chuang, Shih-Youeng
    Chiang, Chang-Jung
    Tsuang, Yang-Hwei
    Chen, Weng-Pin
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (03)
  • [4] MODELING AND ANALYSIS OF THE EFFECT OF DISC DEGENERATION, ARTIFICIAL DISC REPLACEMENT AND SPINAL FUSION ON THE BIOMECHANICS OF THE LUMBAR SPINE
    Mazzoleni, Andre P.
    Gonzalez, Antonio
    Padgett, David
    Hey, Lloyd A.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2008, VOL 2, 2009, : 287 - 295
  • [5] Investigation into Cervical Spine Biomechanics Following Single, Multilevel and Hybrid Disc Replacement Surgery with Dynamic Cervical Implant and Fusion: A Finite Element Study
    Mumtaz, Muzammil
    Zafarparandeh, Iman
    Erbulut, Deniz Ufuk
    [J]. BIOENGINEERING-BASEL, 2022, 9 (01):
  • [6] Biomechanical Characteristics of Cervical Spine After Total Disc Replacement
    Park, Won Man
    Joo, Jeung Woo
    Kim, Kyungsoo
    Lee, Ki-Seok
    Kim, Yoon Hyuk
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2009, 33 (07) : 637 - 644
  • [7] Biomechanical comparison of noncontiguous cervical disc arthroplasty and noncontiguous cervical discectomy and fusion in the treatment of noncontinuous cervical degenerative disc disease: a finite element analysis
    Sun, Xiangyao
    Sun, Siyuan
    Zhang, Tongtong
    Kong, Chao
    Wang, Wei
    Lu, Shibao
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [8] Biomechanical comparison of noncontiguous cervical disc arthroplasty and noncontiguous cervical discectomy and fusion in the treatment of noncontinuous cervical degenerative disc disease: a finite element analysis
    Xiangyao Sun
    Siyuan Sun
    Tongtong Zhang
    Chao Kong
    Wei Wang
    Shibao Lu
    [J]. Journal of Orthopaedic Surgery and Research, 15
  • [9] Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis
    Chen, Lihua
    Wang, Haiyan
    Xu, Guangming
    Liu, Hao
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [10] A biomechanical study of cervical disc degeneration in C4-C6 using finite element analysis
    Kuriakose, V. Arun
    Karthik, Varshini
    Manickam, P. Susai
    Kumar, D. Ashok
    [J]. 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2018), 2018, 402