Biomechanical Analysis of Cervical Disc Replacement and Fusion Using Single Level, Two Level, and Hybrid Constructs

被引:58
|
作者
Gandhi, Anup A. [1 ,2 ]
Kode, Swathi [1 ,2 ]
DeVries, Nicole A. [1 ,2 ]
Grosland, Nicole M. [1 ,2 ,3 ]
Smucker, Joseph D. [3 ]
Fredericks, Douglas C. [3 ]
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Ctr Comp Aided Design, Iowa City, IA USA
[3] Univ Iowa, Univ Iowa Hosp & Clin, Dept Orthopaed & Rehabil, Iowa City, IA USA
关键词
total disc replacement; arthroplasty; fusion; spine biomechanics; adjacent segment degeneration; BRYAN; PRESTIGE LP; arthrodesis; disc replacement plus fusion; range of motion; hybrid loading; TERM-FOLLOW-UP; INTERBODY FUSION; SPINE; ARTHROPLASTY; ADJACENT; RADICULOPATHY; ARTHRODESIS; DISKECTOMY;
D O I
10.1097/BRS.0000000000001044
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines. Objective. To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. Summary of Background Data. Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration. Methods. 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control). Results. An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels. Conclusion. Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.
引用
收藏
页码:1578 / 1585
页数:8
相关论文
共 50 条
  • [41] Single level anterior cervical discectomy and fusion for cervical disc herniation in a professional soccer player
    Casagrande, Johnny
    Zoia, Cesare
    Clerici, Giulio
    Uccella, Laura
    Tabano, Antonio
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2016, 56 (06): : 754 - 757
  • [42] A meta-analysis of cervical arthroplasty compared to anterior cervical discectomy and fusion for single-level cervical disc disease
    Xing, Dan
    Ma, Xin-Long
    Ma, Jian-Xiong
    Wang, Jie
    Ma, Tao
    Chen, Yang
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (07) : 970 - 978
  • [43] Is Two-level Cervical Disc Replacement More Cost-effective Than Anterior Cervical Discectomy and Fusion at 7 Years?
    Merrill, Robert K.
    McAnany, Steven J.
    Albert, Todd J.
    Qureshi, Sheeraz A.
    SPINE, 2018, 43 (09) : 610 - 616
  • [44] Outcomes of single-level cervical disc arthroplasty versus anterior cervical discectomy and fusion
    Tracey, Robert W.
    Kang, Daniel G.
    Cody, John P.
    Wagner, Scott C.
    Rosner, Michael K.
    Lehman, Ronald A., Jr.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (11) : 1905 - 1908
  • [45] The Evidence for the Use of Osteobiologics in Hybrid Constructs (Anterior Cervical Discectomy and Fusion and Total Disc Replacement) in Multilevel Cervical Degenerative Disc Disease: A Systematic Review
    Hoelen, Thomay-Claire A.
    Willems, Paul C.
    Loenen, Arjan
    Meisel, Hans Joerg
    Wang, Jeffrey C.
    Jain, Amit
    Buser, Zorica
    Arts, Jacobus J.
    GLOBAL SPINE JOURNAL, 2024, 14 (2_SUPPL) : 120S - 128S
  • [46] Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation
    Liao, Zhenhua
    Fogel, Guy R.
    Wei, Na
    Gu, Hongsheng
    Liu, Weiqiang
    MEDICAL SCIENCE MONITOR, 2015, 21 : 4006 - 4014
  • [47] Is the behavior of disc replacement adjacent to fusion affected by the location of the fused level in hybrid surgery?
    Wu, Ting-kui
    Meng, Yang
    Wang, Bei-yu
    Hong, Ying
    Rong, Xin
    Ding, Chen
    Chen, Hua
    Liu, Hao
    SPINE JOURNAL, 2018, 18 (12): : 2171 - 2180
  • [48] Two-Level Noncontiguous Versus Three-Level Anterior Cervical Discectomy and Fusion A Biomechanical Comparison
    Finn, Michael A.
    Samuelson, Mical M.
    Bishop, Frank
    Bachus, Kent N.
    Brodke, Darrel S.
    SPINE, 2011, 36 (06) : 448 - 453
  • [49] Cervical disc arthroplasty versus fusion for single-level symptomatic cervical disc disease: a meta-analysis of randomized controlled trials
    Hua Jiang
    Zezhang Zhu
    Yong Qiu
    Bangping Qian
    Xusheng Qiu
    Mingliang Ji
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 141 - 151
  • [50] Cervical disc arthroplasty versus fusion for single-level symptomatic cervical disc disease: a meta-analysis of randomized controlled trials
    Boselie, Toon F. M.
    van Santbrink, Henk
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (02) : 153 - 153