Digital evaluation of the accuracy of impression techniques and materials in angulated implants

被引:42
|
作者
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
Ozcelik, Tuncer Burak [2 ]
Yagiz, Ayberk [3 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, TR-10 Mersin, Turkey
[2] Baskent Univ, Fac Dent, Dept Prosthodont, Adana, Turkey
[3] Ay Tasarim Ltd, Ankara, Turkey
关键词
Implant angulation; Splinted direct technique; Indirect technique; Vinyl polysiloxane; Polyether; Vinyl polyether silicone; IN-VITRO; SUPPORTED SUPERSTRUCTURES; 3-DIMENSIONAL ACCURACY; SURGICAL GUIDES; CONNECTION; PROSTHESES; SYSTEM; FIT; HYDROPHILICITY; SILICONE;
D O I
10.1016/j.jdent.2014.10.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants. Methods: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10 degrees or 20 degrees angulated) were fabricated. Two different impression techniques [ splinted direct (D), indirect (I)] and 3 different monophase impression materials [ polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n = 10). Master model and casts were scanned by a modified laser scanner and data were transferred to VRMesh software. Master model and duplicate cast scans were digitally aligned observing the superposition of anatomic markers. Angular and coronal deviations between master and duplicated copings were calculated and data were statistically analyzed. Results: Mean angular and coronal deviations were in a range of 0.205-0.359 degrees and 22.5633.33 mu m, respectively. Statistical analysis revealed that the angulation of implant affected both coronal and angular deviations of the impression copings (P < 0.05). According to statistical analyses, for parallel implants, the accuracy of impression materials and techniques were ranging as VPS-D = PE-D > VPS-I = PE-I > VPES-D > VPES-I from most accurate to the least. For 10 degrees and 20 degrees angulated implants the most accurate material and technique was VPS-D whereas the least accurate combination was VPES-I (P < 0.05). Conclusion: Angulation, impression technique and material were found to be effective on the accuracy of implant impressions. Clinical significance: Clinicians may prefer VPS impression material and splinted direct technique for impressions of both parallel and up to 20 degrees angulated implants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1551 / 1559
页数:9
相关论文
共 50 条
  • [41] Effect of modified tray design on accuracy of different impression techniques for parallel and divergent implants
    Dang, Liem
    Woliansky, Matthew
    Palamara, Joseph
    Abduo, Jaafar
    JOURNAL OF ORAL SCIENCE, 2020, 62 (04) : 439 - 443
  • [42] CLINICALLY ORIENTED EVALUATION OF THE ACCURACY OF COMMONLY USED IMPRESSION MATERIALS
    TJAN, AHL
    WHANG, SB
    TJAN, AH
    SARKISSIAN, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (01): : 4 - 8
  • [43] Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial
    Elashry, Wafaa Youssef
    Elsheikh, Mohamed Maamoun
    Elsheikh, Ali Mohamed
    BMC ORAL HEALTH, 2024, 24 (01):
  • [44] ACCURACY OF ELASTOMER IMPRESSION MATERIALS
    HEMBREE, JH
    JOURNAL OF DENTAL RESEARCH, 1974, 53 (FEB) : 69 - 69
  • [45] Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study
    Basapogu, Sreeramulu
    Pilla, Ajai
    Pathipaka, Suman
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (02) : ZC56 - ZC59
  • [46] Dimensional accuracy on impression reproducibility for inclined implants
    Watanabe, F
    Tawada, Y
    Kanai, F
    Hata, Y
    Kirsch, A
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 297 - 297
  • [47] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [48] Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques
    Awad, Eman Mostafa
    ElSheikh, Mohamed Maamoun
    El-Segai, Azza Abd el moneim
    BMC ORAL HEALTH, 2024, 24 (01):
  • [49] Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner
    Rcch-Ortega, Cristina
    Fernandez-Estevan, Lucia
    Fernanda Sola-Ruiz, Ma
    Agustin-Panadero, Ruben
    Labaig-Rueda, Carlos
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (01): : E89 - E95
  • [50] Evaluation of the accuracy of multiple digital impression systems on a fully edentulous maxilla
    Gutmacher, Zvi
    Kelly, Abigail
    Renne, Walter
    Hoover, Madison
    Mennito, Anthony
    Teich, Sorin
    Cayouette, Monica
    Ludlow, Mark
    QUINTESSENCE INTERNATIONAL, 2021, 52 (06): : 488 - 495