Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study

被引:14
|
作者
Basapogu, Sreeramulu [1 ]
Pilla, Ajai [1 ]
Pathipaka, Suman [1 ]
机构
[1] GDCH, Dept Prosthodont, Hyderabad, Telangana, India
关键词
American dental association; Dimensional stability; Fixed prosthodontics; Impression techniques; Vertical profile projector;
D O I
10.7860/JCDR/2016/17323.7259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The dimensional stability of the impression material could have an influence on the accuracy of the final restoration. Vinyl Polysiloxane Impression materials (VPS) are most frequently used as the impression material in fixed prosthodontics. As VPS is hydrophobic when it is poured with gypsum products, manufacturers added intrinsic surfactants and marketed as hydrophilic VPS. These hydrophilic VPS have shown increased wettability with gypsum slurries. VPS are available in different viscosities ranging from very low to very high for usage under different impression techniques. Aim: To compare the dimensional accuracy of hydrophilic VPS and hydrophobic VPS using monophase, one step and two step putty wash impression techniques. Materials and Methods: To test the dimensional accuracy of the impression materials a stainless steel die was fabricated as prescribed by ADA specification no. 19 for elastomeric impression materials. A total of 60 impressions were made. The materials were divided into two groups, Group1 hydrophilic VPS (Aquasil) and Group 2 hydrophobic VPS (Variotime). These were further divided into three subgroups A, B, C for monophase, one-step and two-step putty wash technique with 10 samples in each subgroup. The dimensional accuracy of the impressions was evaluated after 24 hours using vertical profile projector with lens magnification range of 20X-125X illumination. The study was analyzed through one-way ANOVA, post-hoc Tukey HSD test and unpaired t-test for mean comparison between groups. Results: Results showed that the three different impression techniques (monophase, 1-step, 2-step putty wash techniques) did cause significant change in dimensional accuracy between hydrophilic VPS and hydrophobic VPS impression materials. One-way ANOVA disclosed, mean dimensional change and SD for hydrophilic VPS varied between 0.56% and 0.16%, which were low, suggesting hydrophilic VPS was satisfactory with all three impression techniques. However, mean dimensional change and SD for hydrophobic VPS were much higher with monophase, mere increase for 1-step and 2-step, than the standard steel die (p<0.05). Unpaired t-test displayed that hydrophilic VPS judged satisfactory compared to hydrophobic VPS among 1-step and 2-step impression technique. Conclusion: Within the limitations of this study, it can be concluded that hydrophilic Vinyl polysiloxane was more dimensionally accurate than hydrophobic Vinyl polysiloxane using monophase, one step and two step putty wash impression techniques under moist conditions.
引用
收藏
页码:ZC56 / ZC59
页数:4
相关论文
共 50 条
  • [1] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [2] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [3] Accuracy of Different Elastomeric Impression Materials Using Dual Arch Impression Trays: An In Vitro Study
    Duseja, Sareen
    Shah, Dipti
    Vaishnav, Kalpesh
    Duseja, Shilpa
    Kumar, Santosh
    Desai, Khushboo
    [J]. ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 3 - 8
  • [4] A study on accuracy and dimensional stability of impression body according to impression techniques and directions
    Lee, JY
    Lim, JH
    Cho, JH
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1319 - 1319
  • [5] Dimensional accuracy of models from different impression materials
    Rodrigues, RCS
    Ribeiro, RF
    Antunes, RPA
    Mattos, MGC
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1152 - 1152
  • [6] DENTIN SURFACE REPRODUCTION WITH HYDROPHILIC AND HYDROPHOBIC IMPRESSION MATERIALS
    TAKAHASHI, H
    FINGER, WJ
    [J]. DENTAL MATERIALS, 1991, 7 (03) : 197 - 201
  • [7] Linear dimensional accuracy of a polyvinyl siloxane of varying viscosities using different impression techniques
    Mishra, Sunil
    Chowdhary, Ramesh
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2010, 1 (01) : 37 - 46
  • [8] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [9] Accuracy of data obtained from impression scans and cast scans using different impression materials
    Keul, Christine
    Runkel, Cornelius
    Guth, Jan-Frederik
    Schubert, Oliver
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2020, 23 (02) : 129 - 138
  • [10] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253