Linear dimensional accuracy of a polyvinyl siloxane of varying viscosities using different impression techniques

被引:6
|
作者
Mishra, Sunil [1 ]
Chowdhary, Ramesh [1 ,2 ]
机构
[1] Dent Coll Azamgarh, Dept Maxillofacial Prosthodont & Implantol, Azamgarh, Uttar Pradesh, India
[2] S Nijalingappa Inst Dent Sci & Res, Dept Maxillofacial Prosthodont, Gulbarga 585102, Karnataka, India
关键词
custom tray; dimensional accuracy; impression; polyvinyl siloxane; stock tray;
D O I
10.1111/j.2041-1626.2010.00004.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The present study is an in vitro study to evaluate the linear dimensional accuracy of commercially available polyvinyl siloxanes of varying viscosities using different impression techniques. Methods: Different impression techniques used were: (a) putty wash, with a two-step technique with polyethylene spacer, using a stock tray; (b) putty wash, with a one-step technique, using a stock tray; (c) single-mix technique, utilizing medium viscosity in a custom tray; and (d) multiple-mix technique, utilizing a heavy- and low-viscosity combination in a custom tray. For each technique, 10 impressions were made of a metallic maxillary dentulous master model. Results: The result of this study dictates that a heavy- and low-viscosity combination, double-mix technique in a custom tray produced an accurate result in all dimensions, followed by the single-mix technique, utilizing medium viscosity in a custom tray, and the putty wash two-step technique with polyethylene spacer, using a stock tray. Group 2 putty wash, one-step, simultaneous technique produced the least accurate result in all dimensions. Conclusion: The putty wash two-step techniques were found to be as accurate as the multiple-mix technique, utilizing a heavy- and low-viscosity combination in a custom tray, and the single-mix technique, utilizing medium viscosity in a custom tray. Making custom trays is time consuming and costly.
引用
收藏
页码:37 / 46
页数:10
相关论文
共 50 条
  • [1] Accuracy of three polyvinyl siloxane putty-wash impression techniques
    Nissan, J
    Laufer, BZ
    Brosh, T
    Assif, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (02): : 161 - 165
  • [2] POLYVINYL SILOXANE IMPRESSION MATERIALS - A REVIEW OF PROPERTIES AND TECHNIQUES
    CHEE, WWL
    DONOVAN, TE
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (05): : 728 - 732
  • [3] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    [J]. EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [4] Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study
    Basapogu, Sreeramulu
    Pilla, Ajai
    Pathipaka, Suman
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (02) : ZC56 - ZC59
  • [5] Influence of Tray Rigidity and Impression Technique on Accuracy of Polyvinyl Siloxane Impressions
    Hoyos, Alex
    Soederholm, Karl-Johan
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (01) : 49 - 54
  • [6] Effect of Different Viscosity and Tear Strength of Polyvinyl Siloxane Impression Material on the Accuracy of Dental Implant Impressions
    Haider, Yagthan Mohammed
    Mokhtar, Norehan
    Najim, Zubaida Tariq
    [J]. INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (12): : 101 - 109
  • [7] Comparing Volumetric Dimensional Stability and Accuracy of Newly Formulated Polyvinyl Siloxanether, Polyvinyl Siloxane and Polyether Impression Materials Using Micro-Computed Tomography
    Aslan, Yilmaz Umut
    Ozkan, Yasemin
    [J]. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2019, 9 (02): : 94 - 100
  • [8] Dimensional stability of polyvinyl siloxane impression material reproducing the sulcular area
    Levartovsky, Shifra
    Levy, Guy
    Brosh, Tamar
    Harel, Noga
    Ganor, Yehuda
    Pilo, Raphael
    [J]. DENTAL MATERIALS JOURNAL, 2013, 32 (01) : 25 - 31
  • [9] Dimensional stability and detail reproduction of polyvinyl siloxane impression materials.
    Keskin, Y
    Uludag, BC
    Gürbüz, A
    Hasanreisoglu, U
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 : 447 - 447
  • [10] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253