Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study

被引:14
|
作者
Basapogu, Sreeramulu [1 ]
Pilla, Ajai [1 ]
Pathipaka, Suman [1 ]
机构
[1] GDCH, Dept Prosthodont, Hyderabad, Telangana, India
关键词
American dental association; Dimensional stability; Fixed prosthodontics; Impression techniques; Vertical profile projector;
D O I
10.7860/JCDR/2016/17323.7259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The dimensional stability of the impression material could have an influence on the accuracy of the final restoration. Vinyl Polysiloxane Impression materials (VPS) are most frequently used as the impression material in fixed prosthodontics. As VPS is hydrophobic when it is poured with gypsum products, manufacturers added intrinsic surfactants and marketed as hydrophilic VPS. These hydrophilic VPS have shown increased wettability with gypsum slurries. VPS are available in different viscosities ranging from very low to very high for usage under different impression techniques. Aim: To compare the dimensional accuracy of hydrophilic VPS and hydrophobic VPS using monophase, one step and two step putty wash impression techniques. Materials and Methods: To test the dimensional accuracy of the impression materials a stainless steel die was fabricated as prescribed by ADA specification no. 19 for elastomeric impression materials. A total of 60 impressions were made. The materials were divided into two groups, Group1 hydrophilic VPS (Aquasil) and Group 2 hydrophobic VPS (Variotime). These were further divided into three subgroups A, B, C for monophase, one-step and two-step putty wash technique with 10 samples in each subgroup. The dimensional accuracy of the impressions was evaluated after 24 hours using vertical profile projector with lens magnification range of 20X-125X illumination. The study was analyzed through one-way ANOVA, post-hoc Tukey HSD test and unpaired t-test for mean comparison between groups. Results: Results showed that the three different impression techniques (monophase, 1-step, 2-step putty wash techniques) did cause significant change in dimensional accuracy between hydrophilic VPS and hydrophobic VPS impression materials. One-way ANOVA disclosed, mean dimensional change and SD for hydrophilic VPS varied between 0.56% and 0.16%, which were low, suggesting hydrophilic VPS was satisfactory with all three impression techniques. However, mean dimensional change and SD for hydrophobic VPS were much higher with monophase, mere increase for 1-step and 2-step, than the standard steel die (p<0.05). Unpaired t-test displayed that hydrophilic VPS judged satisfactory compared to hydrophobic VPS among 1-step and 2-step impression technique. Conclusion: Within the limitations of this study, it can be concluded that hydrophilic Vinyl polysiloxane was more dimensionally accurate than hydrophobic Vinyl polysiloxane using monophase, one step and two step putty wash impression techniques under moist conditions.
引用
收藏
页码:ZC56 / ZC59
页数:4
相关论文
共 50 条
  • [31] DIMENSIONAL ACCURACY OF 5 IMPRESSION MATERIALS USING COPPER-SHELL TECHNIQUE
    BRINSDEN, GI
    SORENSEN, S
    MCCLENAHAN, J
    [J]. JOURNAL OF DENTAL RESEARCH, 1964, 43 (5SP) : 911 - &
  • [32] In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making
    Piwowarczyk, A
    Ottl, P
    Büchler, A
    Lauer, HC
    Hoffmann, A
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (02) : 168 - 174
  • [33] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [34] Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study
    Ismail, Ibrahim Ahmed
    Alhajj, Mohammed Nasser
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : E1 - E5
  • [35] Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants
    Zen, Bruno Massucato
    Soares, Eveline Freitas
    Rodrigues, Mariana Agustinho
    Luthi, Leonardo Flores
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 662 - 667
  • [36] Working times of elastomeric impression materials determined by dimensional accuracy
    Tan, E
    Chai, J
    Wozniak, WT
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1996, 9 (02) : 188 - 196
  • [37] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    [J]. BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [38] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830
  • [39] DIMENSIONAL ACCURACY OF COMBINED REVERSIBLE AND IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS
    SUPOWITZ, ML
    SCHNELL, RJ
    DYKEMA, RW
    GOODACRE, CJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (04): : 404 - 409
  • [40] DIMENSIONAL ACCURACY OF EPOXY-RESINS AND THEIR COMPATIBILITY WITH IMPRESSION MATERIALS
    AIACH, D
    MALONE, WFP
    SANDRIK, J